• 제목/요약/키워드: Over all diameter

검색결과 243건 처리시간 0.025초

Nanocomposite-Based Energy Converters for Long-Range Focused Ultrasound Treatment

  • Lee, Seung Jin;Heo, Jeongmin;Song, Ju Ho;Thakur, Ujwal;Park, Hui Joon;Baac, Hyoung Won
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.369-369
    • /
    • 2016
  • A nanostructure composite is a highly suitable substance for photoacoustic ultrasound generation. This allows an input laser beam (typically, nanosecond pulse duration) to be efficiently converted to an ultrasonic output with tens-of-MHz frequency. This type of energy converter has been demonstrated by using a carbon nanotube (CNT)-polydimethylsiloxane (PDMS) composite film that exhibit high optical absorption, rapid heat transition, and mechanical durability, all of which are necessary properties for high-amplitude ultrasound generation. In order to develop the CNT-PDMS composite film, a high-temperature chemical vapor deposition (HTCVD) method has been commonly used so far to grow CNT and then produce a CNT-PDMS composite structure. Here, instead of the complex HTCVD, we use a mixed solution of hydrophobic multi-walled CNT and dimethylformamid (DMF) and fabricate a solution-processed CNT-PDMS composite film over a spherically concave substrate, i.e. a focal energy converter. As the solution process can be applied over a large area, we could easily fabricate the focal transmitter that focuses the photoacoustic output at the moment of generation from the CNT-PDMS composite layer. With this method, we developed photoacoustic energy converters with a large diameter (>25 mm) and a long focal length (several cm). The lens performance was characterized in terms of output pressure amplitude for an incident pulsed laser energy and focal spot dimension in both lateral and axial. Due to the long focal length, we expect that the new lens can be applied for long-range ultrasonic treatment, e.g. biomedical therapy.

  • PDF

스마트 파이로테크닉스 점화장치 개발 (Devlopment of Smart Pyrotechnic Igniter)

  • 이응조
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.252-255
    • /
    • 2007
  • 최근에 선진국에서 아주 빠른 시간(마이크로 초)에 작동이 되고, 크기가 소형이면서, 많은 케이블과 커넥터를 사용하지 않는 Smart Bus Controller(SCB) 기법을 이용한 초소형/초고속(스마트) 점화기술에 집중적인 연구를 진행하고 있는 실정이다. 이와 같은 점화기술은 기존의 점화장치에서 사용하던 케이블과 커넥터 공간을 최소화 할 수 있게 MEMS 기법을 이용하여 케이블과 커넥터 장치를 설계 제작하였고, 저 용량/저 전류에서 작동할 수 있는 플라즈마를 이용한 케이블과 커넥터 장치를 설계 제작하였고, 저 용량/저 전류에서 작동할 수 있는 플라즈마를 이용한 초고속 착화장치를 사용하여 전류와 전압(배터리) 크기와 용량도 많이 감소시킬 수 있다. 스마트 파이로테크닉스 점화장치 개발에는 간결한 회로 점화통제장치 설계 및 제작, 빠른 점화작동시간을 가능하게 하는 플라즈마형 초고속 착화장치 설계 및 특성연구가 필요하다. 본 연구에서는 플라즈마형 초고속 착화장치의 특성연구에 대해 기술하였다.

  • PDF

시접 처리 방법이 직물의 드레이프성에 미치는 영향 (The Effects of the Seam Finish on Fabric Drape)

  • 송영은;추미선
    • 한국의류산업학회지
    • /
    • 제11권3호
    • /
    • pp.453-459
    • /
    • 2009
  • The purpose of this study was to provide the basic knowledge to determine the proper seam finish according to the design of sewing products. Four seam finishes(no seam finishes, over-edged seam finishes, turned-and-stitched seam finishes, and bias-bound seam finishes) were constructed with seams in warp, weft and bias directions of the fabric. Using a drape measurement system involving two 18cm diameter supporting disks and a digital camera, the images of draped specimens were captured and processed. Drape behavior was evaluated in terms of drape coefficient, node number, and drape profile. Drape coefficients of the fabrics increased with seam formation and varied by the seam finishes, however no significant differences in drape coefficients by the seam finishes were observed on the heavier fabric. Node numbers of heavier fabric were more deeply affected by the seam finishes than those of lighter fabric. The specimens with turned-and-stitched seam finishes and bias-bound seam finishes showed significantly smaller node numbers compared to the specimens with no seam finishes and over-edged seam finishes on heavier fabric. The length of the seamed part showed positive correlation with the weight of the specimens and negative correlation with the number of nodes in each seam direction. The maximum length of all draped specimens was found in the same direction as the seam direction. In the case of the lighter fabric, the seam and the seam finish had a great influence on the shape of the draped profile.

Is Rectosigmoid Vaginoplasty Still Useful?

  • Kim, Seok-Kwun;Park, Ji-Woen;Lim, Kwang-Ryeol;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.48-52
    • /
    • 2017
  • Background The ideal vaginoplasty must be successful functionally as well as have a natural appearance, and also must retain its functionality and appearance over the long term. Conventional vaginoplasty techniques have functional limitations and are associated with recurrent complications, but rectosigmoid vaginoplasty is known to have a high satisfaction rate due to its functional similarity with the vagina. We conducted the present study to assess the usability of rectosigmoid vaginoplasty over the course of long-term follow-up. Methods From March 1992 to February 2014, 84 patients were treated with rectosigmoid vaginoplasty; 44 had gender identity disorder, 29 had vaginal agenesis, 8 had female pseudohermaphroditism, and 3 had gynecologic malignancies after radical pelvic surgery. This retrospective study was based on a review of the patients' records, clinical examinations, complications, and questionnaires about appearance, function, and sexual intercourse. Results All patients who underwent rectosigmoid vaginoplasty were discharged within 2 weeks without surgical flap loss. The early complications were partial flap necrosis, difficulty in defecation, mucous hypersecretion, and postoperative ileus. The late complications were vaginal introitus contracture, vaginal prolapse, and difficulty in urination. The mean length and diameter of the neovagina 3.4 years after rectosigmoid vaginoplasty were 13.2 cm and 3.8 cm, respectively. On questionnaires about satisfaction, 70% of patients reported excellent satisfaction, 11% good, 12% fair, and 7% poor. Conclusions Rectosigmoid vaginoplasty is useful, safe, and well-accepted operative method with good functional and cosmetic results, such as natural lubrication and adequate vaginal length and width obtained without requiring the use of a dilator.

Development Status of the DOTIFS: a new multi-IFU optical spectrograph for the 3.6m Devasthal Optical Telescope

  • Chung, Haeun;Ramaprakash, A.N.;Omar, Amitesh;Ravindranath, Swara;Chattopadhyay, Sabyasachi;Rajarshi, Chaitanya V.;Khodade, Pravin
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.51.1-51.1
    • /
    • 2014
  • DOTIFS is a new multi-object Integral Field Spectrograph (IFS) being designed and fabricated by the Inter-University Center for Astronomy and Astrophysics, Pune, India, (IUCAA) for the Cassegrain side port of the 3.6m Devasthal Optical Telescope (DOT). The telescope is constructed by the Aryabhatta Research Institute of Observational Sciences, Nainital (ARIES). Its main scientific objectives are the physics and kinematics of the ionized gas, star formation and H II regions in nearby galaxies. It is a novel instrument in terms of multi-IFU, built in deployment system, and high throughput. It consists of one magnifier, 16 integral field units (IFUs), and 8 spectrographs. Each IFU is comprised of a microlens array and 144 optical fibers, and has $7.4^{\prime\prime}{\times}8.7^{\prime\prime}$ field of view with 144 spaxel elements with a sampling of 0.8" hexagonal aperture. The IFUs can be deployed on the telescope side port over an 8' diameter focal plane by x-y actuators. 8 Identical, all refractive, dedicated fiber spectrographs will produce 2,304 R~1800 spectra over 370-740nm wavelength range with single exposure. Currently, conceptual and baseline design review had been done, and is in the critical design phase with a review planned for later this year. Some of the components have already arrived. The instrument will see its first light in 2015.

  • PDF

정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구 (A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment)

  • 김희진;장경민;김수현;김기범;정은상
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.

A Study on the single crystal growth of the optic-grade $LiTaO_3$ as a electro-optic materials

  • Kim, B.k.;J.K. Yoon
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.526-526
    • /
    • 1996
  • The single crystal of LiTaO3 is well known eletro-optic material as well as the piezoelectric one applied to SAW filter. LiTaO3 has large electro-optic effects, so applied to optical switch, acosto-optic deflector, and optical memory device using photorefractive effects. The crystal growth of SAW-grade LiTaO3 has been studied many aspects, but there is no detail research about optic-grade crystal growth. The conditions of optic-grade LiTaO3 single crystal are as below. The optical transmittance must be over 75%, and axial and radial concentratiom uniformity below 1%. The variation of Curie temperature depending on Li/Ta ratio must be also below 2$^{\circ}C$ and no internal no internal cracks and defects. Because of the limitation of crystal quality, the growing of optic-grade LiTaO3 single crystal is very difficult compared with the growing of SAW-grade. In this research, upper conditions of optic-grade single crystal was investigated after growing of 1 inch diameter and 1.5 inch length LiTaO3 single crystal having no internal cracks and defects using Czochralski method. Curie temperature was determined with DSC and measuring capacitance and lattice parameter was calculated about the grown crystal and ceramic powder samples of various Li/Ta ratio. The result of Tc variation was below 1.2$^{\circ}C$ all over the grown crystal, so it is confirmed that LiTaO3 was grown under congruent melting composition having optical homogeniety. Also, the optical transmittance was about 78%, which was sufficient for optical device.

  • PDF

심미보철용 코어재료와 베니어 세라믹 계면의 전단결합강도 비교 (Shear Bond Strength between Veneered Ceramics and Core Materials for Esthetic Restorations)

  • 김기원;박항민;정인성
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.45-52
    • /
    • 2009
  • Esthetic restorations have been widely used in dental practice, although many studies have focused on the development and improvement of all ceramic restorations. The success of esthetic restorations depends primarily on an optimal bond strength between various veneered ceramics and core materials for esthetic restorations. The purpose of this study was to compare the shear bond strength between various veneered ceramics and core materials for esthetic restorations. 30 metal cores and 20 zirconia cores were fabricated and divided into five groups according to veneered ceramic materials such as Creation porcelain powder, Cercon Ceram Kiss, and IPS e.max ZirPress. Thirty spacimens were prepared using Creation porcelain powder, veneered 3mm height and 3mm in diameter, over the metal cores (n=10). Twenty specimens were prepared using Cercon Ceram Kiss and Zirpress, veneered 3mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1mm/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 18.44 for Uni metal VH/Creation (NCUC); 18.72 for Heraenium/Creation (NCHC); 16.23 for Wirobond C/Creation (NCWC); 13.88 for Zirconia core/$110{\mu}m$ $Al_2O_3$ sandblasting/Cercon Ceram Kiss (ZS110P); 14.61 for Zirconia core/No surface treatment/IPS e.max ZirPress (ZNTH). The mean shear bond strength for NCUC (Uni metal VH/Creation), NCHC (Heraenium/Creation) and NCWC (Wirobond C/Creation) were significantly superior to ZS110P (Zirconia core/$110{\mu}m$ $Al_2O_3$ sandblasting/Cercon Ceram Kiss) and ZNTH(Zirconia core/No surface treatment/IPS e.max ZirPress) (p<0.05).

  • PDF

개 발정주기가 미성숙난자의 핵발달에 미치는 영향 (Effect of Estrus Cycle on the Neclear Development of Preantral Follicle Oocytes in Canine)

  • 최정림;조성균;공일근
    • 한국가축번식학회지
    • /
    • 제25권2호
    • /
    • pp.93-100
    • /
    • 2001
  • 본 연구는 개 난자의 체외성숙을 유도하기 위하여 발정기 및 비발정기의 개로부터 난소를 채취하여 난자의 채취율과 채취된 난자의 크기와 배양액의 종류에 따른 핵 발달율을 조사하기 위하여 수행되었다. 본 연구를 위하여 난소의 채취는 순천축산에서 난소적출술로 회수하여 3$0^{\circ}C$ saline에 담아 실험실로 2시간 이내에 수송하였다. 모든 난소는 항생제가 첨가된 saline으로 3-4회 세척 후 100 mm dish에서 blade로 세절하여 미성숙난자를 회수하였다. 회수된 난자는 발정기와 비발정기 및 110 $\mu\textrm{m}$ 이상과 이하로 구분하여 회수율을 조사하였다. 미성숙난자의 핵 발달을 유도하기 위하여 체외성숙 배양액은 TCM199과 $\alpha$-MEM에 10% FCS, 0.1 mg/$m\ell$ sodium pyruvate, 100 ng/$m\ell$ FSH, 100 ng/$m\ell$ EGF, 1% 775, 100 lU/$m\ell$ penicillin, 100 $\mu\textrm{g}$/$m\ell$ streptomycin 등을 첨가하여 38.5$^{\circ}C$, 5% $CO_2$ incubator에서 72시간 동안 배양하였다. 핵발달율은 45% acetic acid 용액으로 48시간 고정 후 1% Orcein으로 염색하여 조사하였다. 발정기의 난소로부터 110 $\mu\textrm{m}$ 이상의 난자의 회수율 (63.6%)은 비발정기(51.5%)의 것보다 유의적으로 높았다 (P<0.05). 발정기의 난소에서 110 $\mu\textrm{m}$ 이상의 난소당 난자회수율 (22.6개/63.8%)은 비발정기의 것보다 유의적으로 높았다 (P < 0.05). 발정기의 난소에서 110 $\mu\textrm{m}$ 이상의 난자의 MI까지의 핵발달율 (24.3%)은 110 Um이하의 것 또는 비발정기의 110 $\mu\textrm{m}$ 이상 및 이하의 난자의 것보다 유의적으로 높았다 (2.5, 6.8 및 0.0%; P <0.05). 발정기의 110 $\mu\textrm{m}$ 이상 난자의 AT 또는 MII까지의 핵 발달율은 다른 처리군보다 높게 발달하였다. TCM199에서 MI까지의 핵발달율 (21.8%)은 $\alpha$-MEM (10.0%)보다 유의적으로 높았다 (P< 0.05). 그러나 AT까지의 핵 발달율은 TCM199 (7.3%)과 (-MEM (1.1%) 간에는 유의적 차이가 있었으나 (P<0.05), MII까지는 TCM199 (0.9%)과 (-MEM (1.1%)에는 유의차가 없었다. 본 연구결과는 110 $\mu\textrm{m}$ 이상의 난자는 발정기의 난소로부터 더 많은 난자를 회수할 수 있었고, 110 $\mu\textrm{m}$ 이상의 난자들이 MI, AT까지의 핵발달 능력이 높았다. 또한 체외성숙배양액 시 TCM199이 $\alpha$-MEM보다 Mi과AI까지 높은 발달율을 보였다.

  • PDF

한라산 구상나무 치수의 10년간 생장 변화 (Growth Changes in Abies koreana Seedlings of the Hallasan Mountain Over a 10-year Period)

  • 송국만;김재훈;최형순
    • 한국환경과학회지
    • /
    • 제29권3호
    • /
    • pp.209-218
    • /
    • 2020
  • This study was conducted to monitor the growth and development of Abies koreana seedlings in the Hallasan Mountain. Accordingly, the obtained results indicate that the number of A. koreana seedlings increased by 2.6 and 4.8 times in the Yeongsil and Jindallaebat areas, respectively, over the 10-year period. Most of these seedlings were found to be growing on moss-covered rocks. The average tree height over the last 10 years was obtained as 20.4 cm in the Yeongsil area and 3.6 cm in Jindallaebat with growths of 4.1 cm and 1.4 cm, respectively over the last 2 years. Of all the mature trees that were surviving in 2009, 6 died in Yeongsil in 2014 (with an additional 4 in 2018) and 13 in Jindallaebat in 2016. Over the 10-year period, the diameter at breast height of the trees in Yeongsil and Jindallaebat has increased by an average of 0.6 cm and 4.2 cm. Similarly, an average of 6.8 cones was found in the Yeongsil area in 2014 and 26.3 in Jindallaebat in 2016. However, in 2018, no additional cones were found in the former, although an average of 1.4 cones was observed in the latter. With respect to the average temperature and relative humidity, no significant difference could be observed between two monitored areas from 2016 to 2018. However, in July 2017 and February 2018, the average temperature was higher in the Jindallaebat area, while relative humidity was higher in Yeongsil, there by possibly affecting cone growth and flowering between areas. These results indicate the survival and growth of A. koreana seedlings in the Hallasan Mountain is sensitive to the environments of each area. Hence, continuous monitoring of the environment changes and in-depth studies on the flowering and fruiting of A. koreana seedlings needs to be carried out in order to analyze the relationship between their survival rates and changes in weather conditions.