• Title/Summary/Keyword: Over Voltage Protection

Search Result 132, Processing Time 0.037 seconds

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF

Characteristics of Short-Circuit Protector in Pad-Mounted Transformer (지상변압기의 단락보호장치 특성연구)

  • Kim, K.H.;Lee, W.Y.;Sun, C.H.;Kim, D.M.;Kim, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1350-1352
    • /
    • 1995
  • This paper discribed the characteristic of I-t cross-over-point between current limited-fuse and explusion fuse(Bay-O-Net Fuse) and fuse protection in pad-mounted transformer that was generated internal faults and the short circuit of secondary side(load side). In the I-t cross-over-point, current limited fuse was melted when transient recovery voltage was raised rapidly.

  • PDF

A Study on Over Current Protection Method of Unified Power Quality Conditioners (통합 전력품질 제어기의 과전류 보호방법에 관한 연구)

  • Chae Beom-Seok;Lee Woo-Cheol;Lee Taeck-Ki;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coils (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.250-253
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for commnuication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent, their applications in high-frequency commnuication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for commnuication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in 100 [kHz] RingWave voltage than in lightning impulse voltage.

  • PDF

A Modified Current Differential Relay for Transformer Protection (변압기 보호용 수정 전류차동 계전방식)

  • 강용철;김은수;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

Flyback type Snubber Circuit with di/dt Limiting Capability for IGCT in MV Wind Turbines

  • Lee, Kihyun;Song, Seunghoo;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.333-334
    • /
    • 2014
  • Converters employing IGCTs usually require di/dt snubber and Over Voltage Protection (OVP) circuit for the protection of IGCTs and fast diodes. In these IGCT-based converters, conventional di/dt snubber and OVP circuit dissipates a significant amount of power loss. To reduce this loss of conventional di/dt snubber and OVP circuit, this paper proposes a flyback type snubber circuit with di/dt limiting characteristic for IGCT-based converters in medium voltage wind turbines. This flyback type snubber circuit simply consists of a flyback type transformer and diode. The proposed circuit reduces loss and simplifies conventional di/dt snubber by adopting the flyback type transformer. Loss analysis of conventional di/dt snubber and OVP circuit is performed for the 3-level NPC type back-to-back VSC supplied from grid voltage of 6.9kV. The proposed flyback type snubber circuit can save the loss of conventional snubber circuit in the 3L-NPC type back-to-back VSC in multi-MW MV wind turbine. The proposed snubber circuit has a fewer number of components and improved efficiency leading to a reliable and efficient wind turbine systems.

  • PDF

Design of Small Wind Power System DC Voltage Controller for Over-Voltage Protection through Dynamic Brake Resistor at Over Wind Speed Condition (소형풍력 발전시스템의 과풍속 조건에서 제동 저항을 통한 과전압 방지 DC 전압 제어기 설계)

  • Yang, Byung-Ik;Song, Seung-Ho;Lim, Duk-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.91-92
    • /
    • 2017
  • 풍력 발전 시스템에서 정격 풍속 이상의 바람에 대응하기 위해서는 일반적으로 전기적 브레이크와 기계적 브레이크가 요구된다. 기계적 브레이크는 상대적으로 응답성이 느리며 그 시간 동안 발전기 rpm 증가에 따른 DC전압 상승에 대응하는 전기적 브레이크의 역할이 시스템 안정성에 있어 매우 중요한 요소이다. 전기적 브레이크 중에서도 소형풍력 발전시스템에서는 DB(Dynamic Brake)저항을 통해 부하를 걸어주는 방식이 주로 쓰인다. DB 저항 구동에 있어 히스테리시스 루프에 기반한 PWM제어가 일반적으로 통용되는 방식이다. 이러한 방식과 비교하여 제어 안정성, 전압 오버슈트 등의 면에서 우수한 DB저항 제어 방식을 제안하며 히스테리시스 방식과 과도상태 정상상태 특성 비교 및 성능 분석을 시뮬레이션 결과를 통해 제시한다.

  • PDF

Development of High Voltage Switch Stack with Thyristors Stacked in Series (싸이리스타 소자의 직렬연결형 고전압 스위치스택 개발)

  • Son, Y.G.;Oh, J.S.;Jang, S.D.;Cho, M.H.;Ro, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2597-2600
    • /
    • 1999
  • Semiconductor devices can be series stacked for the application of high voltage switching. It can provide high reliability and long lifetime by the safe design with a reasonable margin. The equal voltage distribution at solid-state switches in series should be guaranteed. Static and dynamic voltage division, over current protection must be considered carefully in the design stage. A fast switching thyristor is a good candidate for the high power pulse applications. A high voltage switching module is designed and tested. Its specifications are working voltage of 70 kV, switching pulse width of 120${\mu}s$, peak switching current of 220A, maximum repetition rate of 200pps. The module can be series connected to get higher working voltage. This paper presents the design details and the test results are compared with expected circuit simulations.

  • PDF

A method for reducing the residual voltage of hybrid SPD circuit using choke coils (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Lee, Tae-Hyung;Jo, Sung-Chul;Han, Hoo-Suk;Eom, Ju-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1488-1489
    • /
    • 2006
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for communication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent their applications in high-frequency communication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for communication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in differential mode than in common mode.

  • PDF

A Characteristic Analysis of Four-Phase SRM (4상 SRM의 구동 특성해석)

  • Kim Tae-Hyoung;Ahn Jin-Woo;Lee Dong-Hee;Chen Hao
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.988-991
    • /
    • 2004
  • In the paper, a four-phase 16/12 structure Switched Reluctance motor drive is presented. The construction of the stator and the rotor in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The comparison of the four-phase 16/12 motor and the four-phase 8/6 motor and the comparison of the four-phase 16/12 motor and the three-phase 12/8 motor are made. In the controller, the PWM control variable-speed control, the commutation control, the four quadrants control, the overvoltage protection, the over current protection and the under voltage protection could be achieved. Tested results of the developed prototype are made.

  • PDF