• Title/Summary/Keyword: Output unit

Search Result 965, Processing Time 0.028 seconds

Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System (전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향)

  • Jang, Jae Kyung;Park, Hyemin;Kim, Taeyoung;Yang, Yoonseok;Yeo, Jeongjin;Kang, Sukwon;Paek, Yee;Kwon, Jin Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

Development of an Automatic Sprayer Arm Control System for Unmanned Pest Control of Pear Trees (배나무 무인 방제를 위한 약대 자동 제어시스템 개발)

  • Hwa, Ji-Ho;Lee, Bong-Ki;Lee, Min-Young;Choi, Dong-Sung;Hong, Jun-Taek;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2014
  • Purpose of this study was a development of a sprayer arm auto control system that could be operated according to distance from pear trees for automation of pest control. Auto control system included two parts, hardware and software. First, controller was made with an MCU and relay switches. Two types of ultra-sonic sensors were installed to measure distance from pear trees: one on/off type that detect up to 3 m, and the other continuous type providing 0~5 V output corresponding to distance of 0~3 m. Second, an auto control algorithm was developed to control. Each spraying arm was controlled according to the sensor-based distance from the pear trees. And it could dodge obstacles to protect itself. Max and min signal values were eliminated, when five sensor signals was collected, and then signals were averaged to reduce sensor's noises. According to results of field experiment, auto control test result was better than non auto control test result. Spraying rates were 69.25% (left line) and 98.09% (right line) under non auto control mode, because pear trees were not planted uniformly. But, auto control test's results were 92.66% (left line) and 94.64% (right line). Spraying rate was increased by maintaining distance from tree.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

Development of a Freeway Travel Time Forecasting Model for Long Distance Section with Due Regard to Time-lag (시간처짐현상을 고려한 장거리구간 통행시간 예측 모형 개발)

  • 이의은;김정현
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.4
    • /
    • pp.51-61
    • /
    • 2002
  • In this dissertation, We demonstrated the Travel Time forecasting model in the freeway of multi-section with regard of drives' attitude. Recently, the forecasted travel time that is furnished based on expected travel time data and advanced experiment isn't being able to reflect the time-lag phenomenon specially in case of long distance trip, so drivers don't believe any more forecasted travel time. And that's why the effects of ATIS(Advanced Traveler Information System) are reduced. Therefore, in this dissertation to forecast the travel time of the freeway of multi-section reflecting the time-lag phenomenon & the delay of tollgate, we used traffic volume data & TCS data that are collected by Korea Highway Cooperation. Also keep the data of mixed unusual to applicate real system. The applied model for forecasting is consisted of feed-forward structure which has three input units & two output units and the back-propagation is utilized as studying method. Furthermore, the optimal alternative was chosen through the twelve alternative ideas which is composed of the unit number of hidden-layer & repeating number which affect studying speed & forecasting capability. In order to compare the forecasting capability of developed ANN model. the algorithm which are currently used as an information source for freeway travel time. During the comparison with reference model, MSE, MARE, MAE & T-test were executed, as the result, the model which utilized the artificial neural network performed more superior forecasting capability among the comparison index. Moreover, the calculated through the particularity of data structure which was used in this experiment.

Design of a Fourth-Order Sigma-Delta Modulator Using Direct Feedback Method (직접 궤환 방식의 모델링을 이용한 4차 시그마-델타 변환기의 설계)

  • Lee, Bum-Ha;Choi, Pyung;Choi, Jun-Rim
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.39-47
    • /
    • 1998
  • A fourth-order $\Sigma$-$\Delta$ modulator is designed and implemented in 0.6 $\mu\textrm{m}$ CMOS technology. The modulator is verified by introducing nonlinear factors such as DC gain and slew rate in system model that determines the transfer function in S-domain and in time-domain. Dynamic range is more than 110 dB and the peak SM is 102.6 dB at a clock rate of 2.8224 MHz for voiceband signal. The structure of a ∑-$\Delta$ modulator is a modified fourth-order ∑-$\Delta$ modulator using direct feedback loop method, which improves performance and consumes less power. The transmission zero for noise is located in the first-second integrator loop, which reduces entire size of capacitors, reduces the active area of the chip, improves the performance, and reduces power dissipation. The system is stable because the output variation with respect to unit time is small compared with that of the third integrator. It is easy to implement because the size of the capacitor in the first integrator, and the size of the third integrator is small because we use the noise reduction technique. This paper represents a new design method by modeling that conceptually decides transfer function in S-domain and in Z-domain, determines the cutoff frequency of signal, maximizes signal power in each integrator, and decides optimal transmission-zero frequency for noise. The active area of the prototype chip is 5.25$\textrm{mm}^2$, and it dissipates 10 mW of power from a 5V supply.

  • PDF

Effects of the dietary digestible fiber-to-starch ratio on pellet quality, growth and cecal microbiota of Angora rabbits

  • Yang, Guiqin;Zhao, Fei;Tian, He;Li, Jiantao;Guo, Dongxin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.4
    • /
    • pp.623-633
    • /
    • 2020
  • Objective: Substituting starch with digestible fiber (dF) can improve digestive health of rabbits and reduce costs. Therefore, it is necessary to develop a criterion for dF and starch supply. Effects of the dietary dF-to-starch ratio on pellet quality, growth and cecal microbiota of Angora rabbits were evaluated. Methods: Five isoenergetic and isoproteic diets with increasing dF/starch ratios (0.59, 0.66, 0.71, 1.05, and 1.44) were formulated. A total of 120 Angora rabbits with an average live weight of 2.19 kg were randomly divided into five groups with four replicates. At the end of 40 day feeding trial, cecal digesta were collected to analyse microbiota. Results: The results showed that the dF/starch ratio had linear effects on pellet variables (p<0.01). When the dF/starch ratio was 1.44, the pellets had the lowest powder and highest durability. The dF/starch ratio had unfavorable linear effects on growth variables (p<0.001). When analyzed by quadratic regression, the optimal dF/starch ratios for average weight gain and feed/gain were 0.59 and 0.74, respectively. There were differences in wool yield, fiber length and fiber diameter caused by the dF/starch ratio (p<0.05), and the dF/starch ratios that ranged from 0.66 to 1.06 were appropriate for good results. The cecal microbiota operational taxonomic unit (OTU) number index in the 1.05 dF/starch treatment was higher than that in the 0.66 and 0.71 dF/starch treatments. The higher dF/starch ratio resulted in a higher cecal microbiota OTU number index (p<0.05). The proportion of Ruminococcus in the 0.71 dF/starch treatment was higher than that in the 0.59 dF/starch treatment (p<0.05) Conclusion: The most suitable dF/starch ratio for feed pellet quality is 1.44, and for rabbit growth the optimal range of ratios is from 0.59 to 0.74. With combination of the wool growth, output cost, and cecal microbiota, we suggest that a dietary dF/starch ratio ranging from 0.74 to 1.06 is optimal.

The estimating method of construction workable-quantity per unit time - Focused on Pump-Dredge - (건설기계 시간당작업량(Q) 산정 개선방안 -펌프준설선 작업효율(E)을 중심으로-)

  • Ahn, Bang-Ryul;Tae, Yong-Ho;Suh, Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.3
    • /
    • pp.125-133
    • /
    • 2010
  • Although work-efficiency of construction machinery is a critical factor for estimating its workable-quantity perunit time, the efficiency figure table presented in the Poom-Sam that is used for Construction Cost Estimation of public sectors in Korea is very subjective for practical usage. In order to suggest objective work-efficiency table for a Pump-Dredger, domestic and overseas documentary records were investigated and on-going construction sites were also visited. Moreover, actual work quantities collected from the site visits were compared with the ones calculated based on the Standard Measurement Methods used in Japan. The research found that the table can be revised by means of detailing down by several factors, namely project type, depth of soil, undersea-site shape, and condition on the sea for better estimation of its workable-quantity. The research will be the foundation for applying the rapid development of Construction Equipment and technology to the appropriate cost estimations and the ground work of related studies.

Study on Remote control and monitoring system of the multipurpose guard rail using USN (USN을 이용한 다목적 가드레일의 원격제어 및 모니터링 시스템에 관한 연구)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7176-7181
    • /
    • 2015
  • This thesis is about the system where the solar module is attached to the high functional guardrail posts with anti-weed, anti-plant, and road-kill applied to produce internal power, enabling the integrated control and real-time monitoring of appearance of wildlife and road conditions using the USN. The whole system consists of a photovoltaic module(PV), a detection sensor(pyroelectric), a controller(operation select and motion sensor), the USN system, the DB(sound and flash), an output unit of sound and flash, and the control system of road-kill prevention and safety induction for vehicles. Thus this study aims to address the remote control and monitoring system of multipurpose guardrails to improve road environment, prevent road-kills, protect wild animals, and guide cars safely by using the USN which is combined with new renewable energy and IT convergence technology. As a result of the study on the remote control and monitoring system using the USN, it was ascertained that the response time of the unmanned sensing system was within 5.1 ms with the current consumption of 0.328 mA, and the data transmission speed of the remote control system was 250 kbps with the current consumption of 0.283 mA.

A Study about Water Footprint Evaluation of Industrial Sectors (국내 산업들의 물 발자국 산정에 관한 연구)

  • Kim, Junbeum;Kang, Hun;Park, Kihak
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.400-406
    • /
    • 2013
  • Water footprint means the direct and indirect water resource amount used for the life cycle of different goods, services and industries. In this study, the direct and indirect water resource consumption in industrial sectors were calculated by using water footprint evaluation method. As a result, agriculture and marine product industry takes part of 93% of whole water resource amount, showing the greatest amount of basic unit of water coefficient (637 $m^3/won$) following by petroleum and cool products industry of about 13 $m^3/won$. In the agriculture and marine product industry, the direct water consumption was only 25 billion $m^3$ compared to the indirect water, which is 130 billion $m^3$. The next highest industry was chemical product industry, which consists of 2 billion $m^3$ of the direct water and 4.5 billion $m^3$ of the indirect water consumption. In case of industries which have high direct water, it would be more effective to reduce amount of water related to the industry than to reduce water in actual process. This water footprint of each industry and evaluation method will be useful tool and method for development of national water management policy and regulation.

10% Pentastarch Versus 5% Albumin Solution for Volume Expansion Following Cariopulmonary Bypass in Patients Undergoing Open Heart Surgery (개심수술후 혈량 증가를 위한 10% Pentastarch와 5% Albumin 용액의 비교연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.177-186
    • /
    • 1994
  • Pentastarch is a hydroxyethyl starch similar to hetastarch, but lower average molecular weight and fewer hydroxyethyl groups which result in enhanced enzymatic hydrolysis and faster renal elimination.This report was performed to compare the clinical efficacy and safety of 10 % pentastarch[Pentaspan , group I] for plasma volume expansion after open heart surgery with that of 5% albumin[Plasmanate, group II]. There were no statistically significant differences between the group I [n=18] and group II [n:19] in the preoperative parameters [age, sex, body weight] and operative parameters[bypass time, aorta cross clamping time]. During the first 24 hours after arrival of the patient in the surgical intensive care unit, colloid solution [500--1000 ml] was infused to maintain left atrial pressure of more than 8 mmHg, or cardiac index of 2.0 L/min/M2 of more. In results, there were 3 complications of hypotension immediately after infusion of 5 % albumin solution and 2 among the 3 patients were excluded for the study. However there was no complication after infusion of 10 % pentastarch solution. Hemodynamic responses to infusion was similar for both groups, although in group I a greater increase in both left atrial pressure[mean 1.8 versus 0.7 mmHg, p< 0.05] and right atrial pressure [mean 2.2 versus 1.7 mmHg, p < 0.05] was observed during infusion of the first 500 ml. There were no significant differences in any of the measured respiratory parameters[PaO2, intrapulmonary shunt, and effective lung compliance]. Homodilution with colloid significantly reduced hemoglobin [mean 1.2 versus 0.8 gm/dl], and serum protein and albumin level[total protein;4.8$\pm$ 0.5 versus 5.2 $\pm$0.5 gm/dl, p < 0.05: albumin: 3.2 $\pm$0.4 versus 3.6 $\pm$0.6 gm/dl, p < 0.05] by 6:00 AM on 1 day postoperatively, however there were no significant differences on 7 day postoperatively. The mean serum colloid osmotic pressure and osmolarity was similar in both group.There were no abnormal findings of liver function and kidney function in all the patients. There were no significant between-group differences in bleeding time, platelets, prothrombin time, activated partial thromboplastin time and amount of chest tube output measured on 1st and 7th postoperative day. These findings demonstrated that 10% pentastarch is more effective and safe for plasma volume expension than 5 % albumin solution with no adverse effects on coagulation. Also 10 % pentastarch is less expensive than 5 % albumin and it would appeare to be a reasonable first choice for plasma volume expansion.

  • PDF