• Title/Summary/Keyword: Output performance

Search Result 6,173, Processing Time 0.033 seconds

A Study on the Performance of the Human Service Organizations : An Analysis from the Perspective of Quality of Output (사회복지서비스 기관의 조직성과에 관한 연구 : 서울시 지역사회복지관의 질 산출(quality output)을 중심으로)

  • Kang, Chul-Hee;Chung, Moo-Sung
    • Korean Journal of Social Welfare
    • /
    • v.49
    • /
    • pp.343-378
    • /
    • 2002
  • This study examines the organizational performance of human service organizations from the quality output perspective. Using the 2001 evaluation data about 89 community welfare centers in Seoul, this study attempts to identify the levels of the performance of human service organizations in Korea. This study also attempts to identify the factors that predict performance of human service organizations measured in terms of client satisfaction and experts' evaluation about the functioning of each center. Results are as follows: (1) when pooling 866 clients' satisfaction level into satisfaction score about each center, the average of client satisfaction about the centers is 3.42 at 4 points scale. (2) 41.6% of the community welfare centers is evaluated as "highly qualified" in its overall operation and functioning by the professional evaluation team, (3) the employee reward system(+), practice based on the program guideline manual(+), the portion of the government support grant in its budget(-), the overall employee salary level(-), the level of acquirement of program grants from external sources (-) are the predictors in explaining clients' satisfaction level, and (4) the level of professional expertise of the executive director(+), the level of professional supervision of middle managers(+), the employee reward system(+), the program need assessment(+), the level of client information system(+), the portion of government support grant(-), the overall employee salary level(-) are the predictors for "being highly qualified" in its overall operation and function of each center. Through the empirical analysis, this study provides valuable knowledge about organizational performance of community welfare centers from the quality output perspective. Finally, this study discusses implications for more effective and efficient organizational performance of community welfare centers in Korea.

  • PDF

Identification of DEA Determinant Input-Output Variables : an Illustration for Evaluating the Efficiency of Government-Sponsored R&D Projects (DEA 효율성을 결정하는 입력-출력변수 식별 : 정부지원 R&D 과제 효율성 평가를 위한 실례)

  • Park, Sungmin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.84-99
    • /
    • 2014
  • In this study, determinant input-output variables are identified for calculating Data Envelopment Analysis (DEA) efficiency scores relating to evaluating the efficiency of government-sponsored research and development (R&D) projects. In particular, this study proposes a systematic framework of design and analysis of experiments, called "all possible DEAs", for pinpointing DEA determinant input-output variables. In addition to correlation analyses, two modified measures of time series analysis are developed in order to check the similarities between a DEA complete data structure (CDS) versus the rest of incomplete data structures (IDSs). In this empirical analysis, a few DEA determinant input-output variables are found to be associated with a typical public R&D performance evaluation logic model, especially oriented to a mid- and long-term performance perspective. Among four variables, only two determinants are identified : "R&D manpower" ($x_2$) and "Sales revenue" ($y_1$). However, it should be pointed out that the input variable "R&D funds" ($x_1$) is insignificant for calculating DEA efficiency score even if it is a critical input for measuring efficiency of a government-sonsored R&D project from a practical point of view a priori. In this context, if practitioners' top priority is to see the efficiency between "R&D funds" ($x_1$) and "Sales revenue" ($y_1$), the DEA efficiency score cannot properly meet their expectations. Therefore, meticulous attention is required when using the DEA application for public R&D performance evaluation, considering that discrepancies can occur between practitioners' expectations and DEA efficiency scores.

Analysis of Soiling for the Installation Direction of PV Module (태양전지 모듈의 설치방향에 따른 오염특성 분석)

  • Lee, Chung Geun;Shin, Woo Gyun;Lim, Jong Rok;Ju, Young Chul;Hwang, Hye Mi;Ko, Suk Whan;Chang, Hyo Sik;Kang, Gi Hwan
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.76-82
    • /
    • 2020
  • Soiling on the surface of a PV module reduces the amount of light reaching the solar cells, decreasing power performance. The performance of the PV module is generally restored after contaminants on the module surface are washed away by rain, but it accumulates at the bottom of the module owing to the thickness of the module frame, causing an output mismatch on the PV module. Since PV modules are usually installed horizontally or vertically outdoors, soiling can occur at the bottom of the PV module, depending on the installation direction due to external environmental factors. This paper is analyzed the output characteristics of a PV module considering its installation direction and the soiling area. The soiling was simulated to use transparent films with 5% transmittance, and the transmission film was attached to the bottom part of the PV module horizontally and vertically. When the soiling area was 33% of the string at the bottom of the PV module, the power output decreased similarly regardless of installation direction. However, when the soiling area was 66% of the string at the bottom of the PV module, it was confirmed that the output performance decreased sharply when installed vertically rather than horizontally.

Development And Application of Three-phase Inverter Output Wave Generator based on SPWM Control to Verify the Performance of LCL filters (LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치 개발 및 적용 연구)

  • Im, Dong-Kyun;Kang, Chang-Kyun;Ha, Won-Jin;Sandagdorj, Chuluunbaatar;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.841-852
    • /
    • 2022
  • In this paper, a 3-phase inverter output waveform generator based on SPWM control was developed to verify the performance of the LCL filter. In order to obtain a test signal for verifying the performance of the filter, first, a DSP-based 3-phase SPWM signal generation algorithm was developed, and then a three-phase voltage source inverter circuit was designed using three half-bridge gate drivers. Next, one LCL filter was experimentally fabricated to verify the effectiveness of the developed SPWM-based 3-phase inverter output waveform generator as a test signal generator, and a DSP-based performance verification system was experimentally constructed. Finally, by comparing the three-phase voltage waveform before and after the LCL filter obtained in the output control experiment with the given time ratio, the effectiveness of the SPWM-based 3-phase inverter output waveform generator was verified.

Novel Soft Decision Generation Technique for Performance Improvement of 3GPP LTE-Advanced Systems with Multiple Antennas (다중 안테나를 사용하는 3GPP LTE-Advanced 시스템의 성능향상을 위한 새로운 연판정 값 생성방식)

  • Park, Jaeyoung;Kim, Jaekwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6838-6844
    • /
    • 2014
  • 3GPP LTE-Advanced systems adopt multiple antennas for high speed data transmission. In general, the receiver complexity of a spatially mutiplexed (SM) multiple-input multiple-output (MIMO) system grows in proportion to the number of candidate vectors. A large number of candidate vectors increases the reliability of the soft output values. The maximum likelihood (ML) signal detection with a large number of candidate vectors achieves high performance. On the other hand, low complexity receiver techniques with a small number of candidate vectors provide soft output values, such as low reliability. This paper addresses the improving reliability of the soft output obtained from a small number of candidate vectors. The improved performance of the proposed technique with the aid of computer simulations is reported.

A Study on the Power Performance Measurement of Transparent Thin-film PV Windows of BIPV Depending on the Inclined Angle (건물일체형 투명 PV복층창의 설치조건에 따른 단위출력당 발전특성 분석연구)

  • An, Young-Sub;Song, Jong-Hwa;Kim, Seok-Ge;Lee, Sung-Jin;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.55-60
    • /
    • 2008
  • This study is on the analysis of power output of transparent thin-film PV windows which are integrated into the building envelope instead of traditional windows. 3 installation angles of vertical, horizontal and $30^{\circ}C$ inclination are investigated. To measure power output of PV windows, full scale mock-up house was designed and constructed. The power performance of PV window system was analyzed for horizontal angle, declination angle and vertical angle according to incline angle. Monitoring data are gathered from November 2006 to August 2007 and statistical analysis is performed to analysis a characteristics of power performance of transparent PV windows. Results show that annual power output of PV window with horizontal angle is 844.4kWh/kWp/year, declination angle 1,060kWh/kWp/year and vertical angle 431.6 kWh/kWp/year.

  • PDF

A Study on the Flow and Power Characteristics of Rotor in the APU (보조동력장치 회전자 유동 및 출력특성에 관한 연구)

  • Yi, Chung-Seob;Jeong, In-Guk;Yun, Ji-Hun;Suh, Jeong-Se;Lee, Tae-Eui
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.805-810
    • /
    • 2011
  • Recently, Use of Auxiliary power unit(APU) is increasing by growing demand for improvement of insufficient electric power and installation of emergency generation devices in military tracked vehicles and civil markets. And the trend is that the units are demanded for smaller size, lighter weight and higher output power, etc to suit consumer demands. To achieve these, it is essential to develop high performance system. Therefore, in this study, it was conducted in numerical analysis to investigate flow characteristics of rotor in APU generator. Also output performance of APU applied on the rotor is analyzed by experimental method. As the result, higher rotating speed of rotor caused high air flow rate at suction and it leads to linear increase of discharging flow rate. The maximum theoretical power was achieved at 12 $m^3$/min of flow rate and, at that time, output power of generator was about 7.825 kW. Also, it can be confirmed the stabilization of output performance is achieved in about 2 seconds by experiment.

A Novel High-Performance Strategy for A Sensorless AC Motor Drive

  • Lee, Dong-Hee;Kwon, Young-Ahn
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.81-89
    • /
    • 2002
  • The sensorless AC motor drive is a popular topic of study due to the cost and reliability of speed and position sensors. Most sensorless algorithms are based on the mathematical modeling of motors including electrical variables such as phase current and voltage. Therefore, the accuracy of such variables largely affects the performance of the sensorless AC motor drive. However, the output voltage of the SVPWM-VSI, which is widely used in sensorless AC motor drives, has considerable errors. In particular, the SVPWM-VSI is error-prone in the low speed range because the constant DC link voltage causes poor resolution in a low output voltage command and the output voltage is distorted due to dead time and voltage drop. This paper investigates a novel high-performance strategy for overcoming these problems in a sensorless ac motor drive. In this paper, a variation of the DC link voltage and a direct compensation for dead time and voltage drop are proposed. The variable DC link voltage leads to an improved resolution of the inverter output voltage, especially in the motor's low speed range. The direct compensation for dead time and voltage drop directly calculates the duration of the switching voltage vector without the modification of the reference voltage and needs no additional circuits. In addition, the proposed strategy reduces a current ripple, which deteriorates the accuracy of a monitored current and causes torque ripple and additional loss. Simulation and experimentation have been performed to verify the proposed strategy.

Analysis on Design Parameters of Small Hydropower Sites with Rainfall Conditions (강우상태에 따른 소수력발전입지의 설계변수 특성 분석)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The correlation between hydrologic performance design parameters of small hydro power(SHP) sites and rainfall condition have been analyzed for major river systems. The model, which can predict flow duration characteristic of stream, was developed to estimate the inflow caused from rainfall. And another model to predict hydrologic performance for SHP plants is established. Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the hydrologic performance characteristics of SHP sites have some difference between the river systems. Especially, the specific design flowrate and specific output of SHP sites located on North Han river and Nakdong river systems have large difference compared with other river systems. It was found that the hydrologic performance design parameters such as specific design flowrate and specific output were affected by rainfall condition in basin area of SHP sites.

A design on optimal PD control system that has the robust performance (강인한 성능을 가지는 최적 PD 제어 시스템 설계)

  • Kim, Dong-Wan;Hwang, Hyeon-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.656-666
    • /
    • 1999
  • In this paper, we design the optimal PD control system which has the robust performance. This PD control system is designed by applying genetic algorithm (GA) to the determination of proportional gain KP and derivative gain KD that are given by PD servo controller, to make the output of plant follow the output of reference model optimally. These proportional and derivatibe gains are simultaneously optimized in the search domain guaranteeing the robust performance of system. And, this PD control system is compared with $\mu$ -synthesis control system for the robust performance. The PD control system designed by the proposed method has not only the robust performance but also the better command tracking performance than that of the $\mu$ -synthesis control system. The effectiveness of this control system is verified by computer simulation.

  • PDF