• Title/Summary/Keyword: Output performance

Search Result 6,161, Processing Time 0.032 seconds

An Analysis of Multi-processor System Performance Depending on the Input/Output Types (입출력 형태에 따른 다중처리기 시스템의 성능 분석)

  • Moon, Wonsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.71-79
    • /
    • 2016
  • This study proposes a performance model of a shared bus multi-processor system and analyzes the effect of input/output types on system performance and overload of shared resources. This system performance model reflects the memory reference time in relation to the effect of input/output types on shared resources and the input/output processing time in relation to the input/output processor, disk buffer, and device standby places. In addition, it demonstrates the contribution of input/output types to system performance for comprehensive analysis of system performance. As the concept of workload in the probability theory and the presented model are utilized, the result of operating and analyzing the model in various conditions of processor capability, cache miss ratio, page fault ratio, disk buffer hit ratio (input/output processor and controller), memory access time, and input/output block size. A simulation is conducted to verify the analysis result.

Evaluation of Power Performance by Anemometer on WTGS (풍력발전기 너셀에 장착된 풍속계를 이용한 출력성능 평가)

  • Kim, Soo-Sang;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.303-310
    • /
    • 2012
  • We carried out the power performance evaluation for 1.5 MW${\times}$2 by using anemometer installed on WTGS(Wind Turbine Generator System) in the wind farm at Shi-hwa bang-a-mu-ri. In this paper, we compared and analyzed the performance of guaranteed output and measured output of WTGS which includes output curve, output coefficient, AEP(Annual Energy Product) and availability, etc.. The power performance of WTGS was optimized in the low wind speed sections(3 m/s ~ 10 m/s) and the measured output was more produced by AEP 109 % and availability 112 % than the guaranteed output. In addition, we could also cut the high cost of testing WTGS performance by using anemometer as a substitute for weather mast.

Performance Analysis of Output Queued Batcher-Banyan Switch for ATM Network (ATM 망에 적용 가능한 출력단 버퍼형 Batcher-Banyan 스위치의 성능분석)

  • Keol-Woo Yu;Kyou Ho Lee
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • This paper proposes an ATM switch architecture called Output Queued Batcher-Banyan switch (OQBBS). It consists of a Sorting Module, Expanding Module, and Output Queueing Modules. The principles of channel grouping and output queueing are used to increase the maximum throughput of an ATM switch. One distinctive feature of the OQBBS is that multiple cells can be simultaneously delivered to their desired output. The switch architecture is shown to be modular and easily expandable. The performance of the OQBBS in terms of throughput, cell delays, and cell loss rate under uniform random traffic condition is evaluated by computer simulation. The throughput and the average cell delay are close to the ideal performance behavior of a fully connected output queued crossbar switch. It is also shown that the OQBBS meets the cell loss probability requirement of $10^{-6}$.

  • PDF

Output Improvement of a Magnetic Levitation Control System

  • Jung, Hae-Young;Na, Seung -You
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.59-70
    • /
    • 1995
  • Output performance improvement using fuzzy logic to the conventional control scheme for a magnetic levitation system is presented in this paper, Adverse characteristics of nonlinearity, unstability, system parameter variation, etc, in the levitation system are partially overcome by the general fuzzy control action. Using a PD type compensator, a coarse framework of output performance is provided to the levitation system. Then a fine regulation to the output performance requirement is obtained by the natural description of the control action in the form of fuzzy logic controller. This control action soothes the adverse characteristics of the levitation system. In this way a better output performance can be obtained in a real time experiment.

  • PDF

Performance of a Rectangular Smart Antenna in CDMA Basestation (CDMA 기지국에 설치된 평면 스마트 안테나의 성능 고찰)

  • Hong, Young-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3C
    • /
    • pp.323-330
    • /
    • 2007
  • Performance indicators such as output SNR, SIR, SINR for rectangular smart antennas in CDMA basestations have been derived. Simulations have been carried out to find the rectangular smart antenna performance while varying the input SNR, number of antenna elements, and the interferers' spatial distributions. Simplified Conjugate Gradient Method was chosen as the underlying beam forming algorithm. It has been shown that the performance of a rectangular smart antenna is similar to that of the linear one having the same number of elements when the interferers are randomly distributed over the whole azimuth angle range.

Field Test for Performance Evaluation of a Tubular Turbine in Marine Small Hydro Power Plant (해양소수력발전소 튜블러 수차 성능평가를 위한 현장시험)

  • Hwang, Yeong-Ho;Lee, Young-Ho;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1070-1077
    • /
    • 2011
  • This study includes field test results for performance evaluation of a tubular turbine in marine small hydro power plant. Minimum output power of the tested turbine generator is examined with using of the measured effective head, output power and efficiency. For the rated and maximum output power tests, corrected values from the result of turbine model test are used for the performance evaluation, because experimental conditions of field test at the rated and maximum output powers are restricted correctly. Performance of the test turbine shows good conformance with the suggested guarantee values of output power and efficiency at the measured points of minimum, rated and maximum output power.

Method for Improving Overmodulation Performance of an Inverter for the Enhanced Output Torque of AC Motors (교류 전동기의 출력 토크 향상을 위한 인버터의 과변조 성능 개선 방법)

  • Jeong, Hye-In;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.273-278
    • /
    • 2019
  • This study proposes a method for improving the overmodulation performance of a three-phase inverter to obtain an enhanced output torque for the AC motors. In the inverter-fed AC motor drives, the output torque of the motor can be enhanced by utilizing the overmodulation region as well as the linear modulation regions of the inverter. The overmodulation method is used for this overmodulation operation of the inverter. However, the voltage gain, the ratio of the output voltage of the inverter to the reference voltage achieved by the conventional overmodulation methods becomes nonlinearly smaller than unity. Therefore, the effect of improving the output torque of the AC motors is insignificant even when the overmodulation region is utilized. In this study, we propose a method that improves the overmodulation performance of the inverter by compensating the limited amount of the reference voltage in the overmodulation operation to enhance the output torque of the AC motors. The effectiveness of the proposed method is verified through the simulations and experiments with an 800 W permanent magnet synchronous motor.

A Study on the Control of Recognition Performance and the Rehabilitation of Damaged Neurons in Multi-layer Perceptron (다층 퍼셉트론으 인식력 제어와 복원에 관한 연구)

  • 박인정;장호성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.2
    • /
    • pp.128-136
    • /
    • 1991
  • A neural network of multi layer perception type, learned by error back propagation learning rule, is generally used for the verification or clustering of similar type of patterns. When learning is completed, the network has a constant value of output depending on a pattern. This paper shows that the intensity of neuron's out put can be controlled by a function which intensifies the excitatory interconnection coefficients or the inhibitory one between neurons in output layer and those in hidden layer. In this paper the value of factor in the function to control the output is derived from the know values of the neural network after learning is completed And also this paper show that the amount of an increased neuron's output in output layer by arbitary value of the factor is derived. For the applications increased recognition performance of a pattern than has distortion is introduced and the output of partially damaged neurons are first managed and this paper shows that the reduced recognition performance can be recovered.

  • PDF

Adaptive Input-Output Linearization Technique of Interior Permanent Magnet Synchronous Motor with Specified Output Dynamic Performance

  • Kim, Kyeong-Hwa;Baik, In-Cheol;Moon, Gun-Woo;Lee, Dae-Sik;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.2
    • /
    • pp.58-66
    • /
    • 1996
  • An adaptive input-output linearization technique of an interior permanent magnet synchronous motor with a specified output dynamic performance is proposed. The adaptive parameter estimation is achieved by a model reference adaptive technique where the stator resistance and the magnitude of flux linkage can be estimated with the current dynamic model and state observer. Using these estimated parameters, the linearizing control inputs are calculated. With these control inputs, the input-output linearization is performed and the load torque is estimated. The adaptation laws are derived by the Popov's hyperstability theory and the positivity concept. The robustness and the output dynamic performance of the proposed control scheme are verified through the computer simulations.

  • PDF

A Predictive Model of the Generator Output Based on the Learning of Performance Data in Power Plant (발전플랜트 성능데이터 학습에 의한 발전기 출력 추정 모델)

  • Yang, HacJin;Kim, Seong Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8753-8759
    • /
    • 2015
  • Establishment of analysis procedures and validated performance measurements for generator output is required to maintain stable management of generator output in turbine power generation cycle. We developed turbine expansion model and measurement validation model for the performance calculation of generator using turbine output based on ASME (American Society of Mechanical Engineers) PTC (Performance Test Code). We also developed verification model for uncertain measurement data related to the turbine and generator output. Although the model in previous researches was developed using artificial neural network and kernel regression, the verification model in this paper was based on algorithms through Support Vector Machine (SVM) model to overcome the problems of unmeasured data. The selection procedures of related variables and data window for verification learning was also developed. The model reveals suitability in the estimation procss as the learning error was in the range of about 1%. The learning model can provide validated estimations for corrective performance analysis of turbine cycle output using the predictions of measurement data loss.