• Title/Summary/Keyword: Output dose

Search Result 290, Processing Time 0.045 seconds

Fabrication and Dosimetry Characteristics of Intracavitary Cones for Radiotherapy (방사선 강내치료를 위한 소조사면 전자선cone의 선량분포 특성)

  • 나수경;권수일
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.95-102
    • /
    • 2001
  • The intracavitary cones were designed which were made of stainless steel and have scratched inside cone to be generated electron scatter and designed to be attached easily to the LINAC collimator and controlled cones length to be contacted smoothly between the patient and the cone tip. Two types of intracavitary cones were designed. One is the straight end cones with circular opening on the distal end and the other is 30 degree beveled end cones with elliptical opening on the distal end. Each type of intracavitary cone ranged in daimeter from 2.5 cm to 3.5 cm and required a separate set of lower trimmer annulias cone diameter. The film phantom was designed with an internal cassette that accurately aligned the film edge with the film phantom surface. Film optical density data were measured by photodensitometer(Wellhofer 700i) Dosimetry measurements were made to commission the LINAC for 6 - 20 MeV electron using the intracavitary cones. Isodose curves were measured for all energy and cones combinations. Output is defined as the maximum dose per MU along the clinical central axis in water at 113 cm SSD. Calibration output, defined to be the output for the 15cm$\times$15cm diameter straight cone, was adjusted to 1.00 cGy/MU at each energy according to the TG-21 protocol.

  • PDF

Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment (전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구)

  • Yang, Seungwoo;Han, Moojae;Shin, Yohan;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, it was intended to replace the existing plane parallel ionization chamber, which requires cross-calibration in electron beam treatment. The semiconductor compounds HgI2 was fabricated as detector, and the characteristics of HgI2 detector for the 6, 9 and 12 MeV electron beam was analyzed in the linear accelerator. It was also intended to evaluate the possibility of substitution with existing detectors and their applicability as electron beam dosimetry and to use them as a basic study of the development of electronic beam dosimeter. As a result of reproducibility, RSD was 0.4246%, 0.5054%, and 0.8640% at 6, 9, and 12 MeV energy, respectively, indicating that the output signal was stable. As a result of the linearity, the R2 was 0.9999 at 6 MeV, 0.9996 at 9 MeV, and 0.9997 at 12 MeV showed that the output signal is proportional to HgI2 as the dose is increased. The HgI2 detector of this study is highly applicable to electron beam measurement, and it may be used as a basic research on electron beam detection.

Shielding Performance of PLA and Tungsten Mixture using Research Extruder (연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능)

  • Do-Seong Kim;Tae-Hyung Kim;Myeong-Seong Yoon;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 2023
  • In this study, 3D printing technology was used to compensate for the shortcomings of the use of lead, which has proven to have excellent shielding performance, and to control unnecessary human exposure. 3D printers can implement three-dimensional shapes and can immediately apply individual ideas, which has great advantages in maintaining technology supplementation while reducing the cost and duration of prototyping. Among the various special 3D printers, the FDM method was adopted, and the filament used for output was manufactured using a research extruder by mixing two materials, PLA (Poly-Lactic-Acid) and tungsten. The purpose was to verify the validity through dose evaluation and to provide basic information on the production of chapezones of various materials. The mixed filament was implemented as a morphological shield. Filaments made of a research extruder by mixing PLA and tungsten were divided into 10 %, 20 %, 30 %, 40 %, and 50 % according to the tungsten content ratio. Through the process of 3D Modeling, STL File storage, G-code generation, and output, 10 cm × 10 cm × 0.5 cm was manufactured, respectively, and dose and shielding ability were evaluated under the conditions of tube voltages of 60 kVp, 80 kVp, 100 kVp, 120 kVp, and tube currents of 20 mAs and 40 mAs.

Effects of Rumen Protozoa of Brahman Heifers and Nitrate on Fermentation and In vitro Methane Production

  • Nguyen, S.H.;Li, L.;Hegarty, R.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.6
    • /
    • pp.807-813
    • /
    • 2016
  • Two experiments were conducted assessing the effects of presence or absence of rumen protozoa and dietary nitrate addition on rumen fermentation characteristics and in vitro methane production in Brahman heifers. The first experiment assessed changes in rumen fermentation pattern and in vitro methane production post-refaunation and the second experiment investigated whether addition of nitrate to the incubation would give rise to methane mitigation additional to that contributed by defaunation. Ten Brahman heifers were progressively adapted to a diet containing 4.5% coconut oil distillate for 18 d and then all heifers were defaunated using sodium 1-(2-sulfonatooxyethoxy) dodecane (Empicol). After 15 d, the heifers were given a second dose of Empicol. Fifteen days after the second dosing, all heifers were allocated to defaunated or refaunated groups by stratified randomisation, and the experiment commenced (d 0). On d 0, an oral dose of rumen fluid collected from unrelated faunated cattle was used to inoculate 5 heifers and form a refaunated group so that the effects of re-establishment of protozoa on fermentation characteristics could be investigated. Samples of rumen fluid collected from each animal using oesophageal intubation before feeding on d 0, 7, 14, and 21 were incubated for in vitro methane production. On d 35, 2% nitrate (as $NaNO_3$) was included in in vitro incubations to test for additivity of nitrate and absence of protozoa effects on fermentation and methane production. It was concluded that increasing protozoal numbers were associated with increased methane production in refaunated heifers 7, 14, and 21 d after refaunation. Methane production rate was significantly higher from refaunated heifers than from defaunated heifers 35 d after refaunation. Concentration and proportions of major volatile fatty acids, however, were not affected by protozoal treatments. There is scope for further reducing methane output through combining defaunation and dietary nitrate as the addition of nitrate in the defaunated heifers resulted in 86% reduction in methane production in vitro.

Physical Aspect of The Gamma Knife and Its Clinical Application (감마나이프의 물리적 특성 및 그의 임상적 적용)

  • Yi Byong Yong;Chang Hyesook;Choi Eunkyung;Whang C. Jin;Kwon Y.
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.153-158
    • /
    • 1991
  • The first Leksell Gamma Knife unit (LGU-type B) for radiosurgery in Asia was installed in Asan Medical Center. Mechanical accuracy, output, dose profiles for each collimators were measure during acceptance test. Sixty eight patients (sixty nine cases) had undergone radiosugery from May 1990 to September 1990. AVM cases were 24 cases $(35\%)$, acoustic tumor 10 $(14\%)$, pituitary adenoma 4 $(6\%)$, metastatic tumor 18 $(26\%)$, meningioma 6$(9\%)$ and others 18 $(25\%)$. Dose of $25\;Gy\sim100\;Gy$ was delivered at one time according to disease, location and sizes.

  • PDF

Effect of Recombinant Human Epidermal Growth Factor(DWP 401) on Gastric Secretion and Ulcers in Rats (재조합 인간 상피세포 성장인자(DWP 401)의 흰쥐 위액분비 및 궤양에의 작용)

  • Lee, Eun-Bang;Cheon, Seon-A;Lee, Eun-Sim;Kim, Ok-Gyeong
    • YAKHAK HOEJI
    • /
    • v.40 no.4
    • /
    • pp.456-461
    • /
    • 1996
  • The effects of human epidermal growth factor(EGF) which was produced by recombinant DNA technique was investigated on gastric secretion, gastric lesion and ulcer models in rats. The EGF showed significant inhibition of secretion of gastric juice and total acid output, at 0.4mg/kg, id and also inhibited Shay ulceration at 0.4mg/kg, id in rats. The lesion induced by absolute ethanol was significantly reduced by oral administration of EGF at 0.4mg/kg. Likewise, EGF caused significant inhibition of indomethacin induced gastric ulcer at oral doses of 0.2 and 0.4mg/kg. The EGF produced dose-dependent inhibition of gastric ulcer induced by acidified aspirin, but showed no significant inhibition at oral doses of 0.1, 0.2 and 0.4mg/kg. The chronic gastric ulcer induced by injection of 20% acetic acid solution was significantly reduced by oral doses of 0.1 and 0.4mg/kg of EGF. Duodenal ulcer induced by mepirizole was dose-dependently inhibited by oral doses of 0.1, 0.2 and 0.4mg/kg of EGF. These data suggest that EGF possesses pronounced inhibitory action in gastric ulcer and duodenal ulcer of rats.

  • PDF

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

Fabrication of Microwave Applicator for Hyperthermia and Thermal Distribution in Tissues (종양의 온열치료를 위한 마이크로잔 조사장치의 제작과 응용)

  • Chu S. S.;Lee J. T.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is bases on radiobiological and clinical evidence indicated that there may be a significant therapeutic advantage with the use of heat alone or combined with radiation or chemotherapy, There are many methods for generating heat for localized tumor as like radiofrequency, microwave, electromagnetic induction and ultrasound. But it is very difficult to be even thermal dose distribution and stable output of power and then the detection of temperature in tumor is difficult to be precise with thermocouples and semiconductor sensors. We designed the microwave heating generator, dipole antenna applicators and autometic temperature controlled thermocouples for localized hyperthermia on skin and in cavities. 1. The microwave generator with 120 W, 2,450MHz magnetron could be heating up to $40^{\circ}C\~50^{\circ}C\;for\;1\~2$ hours in living tissues. 2. The thermal dose distribution in tissue with microwave was described $42^{\circ}C\~44^{\circ}C$ with in 3 cm depth and $2\~6cm$ diameter area. 3. Skin surface heating applicator with spiral 3 times wave length antenna radiated high Power of microwave. 4, Intracavitary heating applicator with dipole antenna with autometic control temperature sensor kept up continuously constant temperature in tissue. 5. For constant thermal distribution, applied two steps power with 10W microwave after $17\~20W$ during first 10 minutes. 6. The cooling rate by blood flew in living tissue was rised as $10\%$ then meats.

  • PDF

TID and SEL Testing on OP-Amp. of DC/DC Power Converter (DC/DC 컨버터용 OP-Amp.의 TID 및 SEL 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.101-108
    • /
    • 2017
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The advanced DC/DC converter uses a PWM-IC with OP-Amp. (Operational Amplifier) to control a MOSFET (metal-oxide semiconductor field effect transistor), which is a switching component, efficiently. In this paper, it is shown that the electrical characteristics of OP-Amp. are affected by radiations of ${\gamma}$ rays using $^{60}Co$ for TID (Total Ionizing Dose) testing and 5 heavy ions for SEL (Single Event Latch-up) testing. TID testing on OP-Amp. is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the OP-Amp. operation is evaluated SEL testing after implementation of the controller board.

A Study on Optimized Design of Wideband Pulsed Gamma-ray Detectors (광대역 펄스감마선 탐지센서 최적화설계에 관한 연구)

  • Jeong, Sang-hun;Lee, Nam-ho;Son, Eui-seung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1121-1124
    • /
    • 2015
  • In this paper, we propose and demonstrate an optimal design of wideband pulsed gamma-ray detectors. Pulsed gamma-ray detectors are designed to operate in a dose rate of $1{\times}10^6{\sim}1{\times}10^8rad(Si)/s$. The input parameter was derived based on the energy ratio of pulse gamma-ray spectrum and the time of the energy. The sensor output current was calculated based on the dose rate control circuit. Using the N-type Epi Wafer, the optimum condition detection sensor was designed based on TCAD. The simulation results show that the optimal Epi layer thickness is 45um when applied voltage 3.3V. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. Pulse gamma-ray detector diameter is the 1.3mm.

  • PDF