• Title/Summary/Keyword: Output Monitoring

Search Result 594, Processing Time 0.03 seconds

The Study of Optimized Combustion Tuning Method for Fossil Power Plant (발전용 보일러의 최적연소조정기법에 대한 실험적 연구)

  • Jung, Jae-Jin;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.45-52
    • /
    • 2009
  • Fossil power plants firing lower grade coals or equipped with modified system for $NO_x$ controls are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. In order to develop a on-line combustion tuning system, field test was conducted at operating power boiler. During the field test the exhaust gases' $O_2,\;NO_x$ and CO was monitored by using a spatially distributed monitoring grid located in the boiler's high temperature vestibule and upper convective rear pass region. At these locations, the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. using these monitored information we can improving combustion at every point within the furnace, therefore the boiler can operate at reduced excess $O_2$ and gas temperature deviation, reduced furnace exit gas temperature levels while also reducing localized hot spots, corrosive gas conditions, slag or clinker formation and UBC. Benefits include improving efficiency, reducing $NO_x$ emissions, increasing output and maximizing availability. Discussion concerning the reduction of greenhouse gases is prevalent in the world. When taking a practical approach to addressing this problem, the best way and short-term solution to reduce greenhouse gases on coal-fired power plants is to improve efficiency. From this point of view the real time optimized combustion tuning approach is the most effective and implemented with minimal cost.

A Study on the Development of Test Facility for Safety System Software V/V in Nuclear Power Plant (원자력발전소 안전계통 소프트웨어의 확인/검증을 위한 시험장치 개발에 관한 연구)

  • Lee, Sun-Sung;Suh, Young;Moon, Chae-Joo
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.96-102
    • /
    • 1998
  • The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants is a system that includes computer hardware, software, firmware, and interfaces. To develop the computer systems graded with nuclear safety class, the developing environments have to be required in advance and the developed software have to be verified and validated in accordance with nuclear code and standards. With this requirements, the test facility for Inadequate Core Cooling Monitoring System (ICCMS) as one of safety systems in the nuclear power plants was developed. The test facility consists of three(3) parts such as Input/Output (I/O) simulator, Plant Data Acqusition System (PDAS) cabinets and supervisory computer. The performance of the system was validated by manual test procedure.

  • PDF

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Development of Real time Air Quality Prediction System

  • Oh, Jai-Ho;Kim, Tae-Kook;Park, Hung-Mok;Kim, Young-Tae
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.73-78
    • /
    • 2003
  • In this research, we implement Realtime Air Diffusion Prediction System which is a parallel Fortran model running on distributed-memory parallel computers. The system is designed for air diffusion simulations with four-dimensional data assimilation. For regional air quality forecasting a series of dynamic downscaling technique is adopted using the NCAR/Penn. State MM5 model which is an atmospheric model. The realtime initial data have been provided daily from the KMA (Korean Meteorological Administration) global spectral model output. It takes huge resources of computation to get 24 hour air quality forecast with this four step dynamic downscaling (27km, 9km, 3km, and lkm). Parallel implementation of the realtime system is imperative to achieve increased throughput since the realtime system have to be performed which correct timing behavior and the sequential code requires a large amount of CPU time for typical simulations. The parallel system uses MPI (Message Passing Interface), a standard library to support high-level routines for message passing. We validate the parallel model by comparing it with the sequential model. For realtime running, we implement a cluster computer which is a distributed-memory parallel computer that links high-performance PCs with high-speed interconnection networks. We use 32 2-CPU nodes and a Myrinet network for the cluster. Since cluster computers more cost effective than conventional distributed parallel computers, we can build a dedicated realtime computer. The system also includes web based Gill (Graphic User Interface) for convenient system management and performance monitoring so that end-users can restart the system easily when the system faults. Performance of the parallel model is analyzed by comparing its execution time with the sequential model, and by calculating communication overhead and load imbalance, which are common problems in parallel processing. Performance analysis is carried out on our cluster which has 32 2-CPU nodes.

  • PDF

Measuring Fluid Balance in Patients with Cancers: Comparison between Cumulative Intake and Output Records and Body Weight Change (암환자의 수분 균형 상태 사정 방법 비교: 수분 섭취 및 배설량 측정법과 체중측정법)

  • Lee, Jin-Hong;Park, Hee-Jung;Kim, Jeong-Hwa;Suh, Eun-Young
    • Asian Oncology Nursing
    • /
    • v.11 no.3
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The purpose of the study was to evaluate the accuracy of two different fluid intake measurement methods (fluid only vs. all dietary intake) in measuring fluid balance compared to body weight change among patients with cancers. Methods: A total of 60 cancer patients in an urban cancer center in South Korea participated in the study. Adult patients who were over 18 years old; having 24-hour I&O order; and taking either normal regular diet or soft blend diet were included. Demographic information and disease related information were also gathered. The data were analyzed using SPSS 18.0 program. Results: Measuring 'fluid only' for oral intake was a more accurate measure than measuring 'all dietary intake' (p=.026 vs. p=.094). Both methods had positive correlations with the amount of weight change (r=.329, p=.010; r=.303, p=.019). Measuring body weight was a more accurate and efficient way of evaluating the fluid balance than 24 hour cumulative I&O. Conclusion: Developing clinical manual for selecting proper patients who needs fluid balance monitoring is imperative. Administering weight check and/or 24 hour cumulative I&O should be considered thoroughly based on solid nursing evidence in future.

Effects of Painless Delivery on Hemodynamic Changes of Parturients with Epidural Analgesia (경막외진통을 이용한 무통분만이 임산부의 혈역학 변동에 미치는 영향)

  • Lee, Sang-Ha;Jang, Young-Ho;Cheun, Jae-Kyu
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 1996
  • Background; Epidural analgesia for controlling labor pain has recently gained world-wide popularity. However, many patients scheduled for continuous epidural analgesia voice concern over harmful effects to their fetus and other possible complications such as hemodynamic changes, back pain and neurologic sequelae etc. The aim of this study was to evaluate the hemodynamic changes with and without epidural block as a measure to determine the safety of epidural analgesia during labor and delivery. Methods: Twenty healthy subjects were divided equally into two groups(Group 1 without epidural block, and Group 2 with epidural block) and serial hemodynamic measurements were taken in all subjects with transcutaneous impedence cardiography. The epidural catheter was inserted at the level of $L_{3,4}$ in Group 2 and analgesia was maintained using 0.25% bupivacaine mixed with fentanyl. Results: Cardiac output increased slightly with cervical dilatation in both groups, but no significant differences were found between the two groups. Similarly, no significant differences were found in blood pressures between the two groups. Stroke volume and end-diastolic volume indices were slightly decreased in group 1 and slightly increased in group 2. However, there were no significant differences between the two groups. The ejection fraction was nearly constant and ranging 56~59%. Conclusion: We concluded epidural analgesia for labor and delivery is a safe technique for the parturients since results indicated no significant differences in hemodynamic changes, as compared to the control group.

  • PDF

Real-time Implementation of Sound into Color Conversion System Based on the Colored-hearing Synesthetic Perception (색-청 공감각 인지 기반 사운드-컬러 신호 실시간 변환 시스템의 구현)

  • Bae, Myung-Jin;Kim, Sung-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.12
    • /
    • pp.8-17
    • /
    • 2015
  • This paper presents a sound into color signal conversion using a colored-hearing synesthesia. The aim of the present paper is to implement a real-time conversion system which focuses on both hearing and sight which account for a great part of bodily senses. The proposed method of the real-time conversion of color into sound, in this paper, was simple and intuitive where scale, octave and velocity were extracted from MIDI input signals, which were converted into hue, intensity and saturation, respectively, as basic elements of HSI color model. In experiments, we implemented both the hardware system for delivering MIDI signals to PC and the VC++ based software system for monitoring both input and output signals, so we made certain that the conversion was correctly performed by the proposed method.

A Detection of Vegetation Variation Over North Korea using SPOT/VEGETATION NDVI (SPOT/VEGETATION NDVI 자료를 이용한 북한지역 식생 변화 탐지)

  • Yeom, Jong-Min;Han, Kyung-Soo;Lee, Chang-Suk;Park, Youn-Young;Kim, Young-Seup
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.28-37
    • /
    • 2008
  • In this study, we perform land surface monitoring of NDVI (Normalized Difference Vegetation Index) variation by using remote sensing data during 1999-2005 over North Korea, which can't easily access to measure directly land surface characteristics due to one of the world's most closed societies. North Korea forest region has most abundant forest vegetation - so called Lungs of Korea in the Korea peninsula. NDVI represents vegetation activity used in many similar studies. In this study, we detect vegetation variation and analysis factors of the change over North Korea. By using variation of NDVI, we can infer that effect of drought over North Korea, and reduced vegetation indices by typhoon in North Korea. Land surface type except barren ground with decreased NDVI value is considered as when North Korea region was suffering from drought and typhoon effects, which show lower than mean of 7-year NDVI value. Especially, in recently, the food production of North Korea with political and economical issues can be inferred indirectly these trends by using estimated output data from this study.

  • PDF

Multi-wavelength Study of Blazars Using Variability as a Tool

  • Baliyan, Kiran S.;Kaur, Navpreet;Chandra, Sunil;Sameer, Sameer;Ganesh, Shashikiran
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2016
  • Active galactic nuclei (AGN) are too compact to be resolved by any existing optical telescope facility, making it difficult to understand their structure and the emission processes responsible for their huge energy output. However, variability, one of their characteristic properties, provides a tool to probe the inner regions of AGN. Blazars are the best candidates for such a study, and hence a considerable amount of effort is being made to investigate variability in these sources across the electromagnetic spectrum. Here, using the Mt. Abu infrared observatory (MIRO) blazar monitoring program, we present intra-night, inter-night, and long term aspects of the variability in S5 0716+71, 3C66A, and OJ 287. These stars show significant variability on short (a few tens of mins, to a few hours, to a few days) to long term (months to years) timescales. Based on the light travel time argument, the shortest variability timescales (micro-variability) provide upper limits to the size of the emission region. While S5 0716 shows a very high duty cycle of variability (> 80 %), 3C66A shows a much lower intra day variability (IDV) duty cycle (< 20 %). All three show rapid variations within 2.5 to 3.5 hr, which, perhaps, are generated near the vicinity of black holes. Assuming this, estimates of the masses of the black holes are made at ~109, 8×108, and 2.7×109 M for S5 0716+71, 3C66A, and OJ 287, respectively. Multi-wavelength light-curves for the blazar PKS 1510-089 are discussed to infer the emission processes responsible for the recent flaring episodes in this source.

The Usefulness of Transesophageal Echocardiography During Heart Surgery (개심술을 시행하는 환자에서 경식도 심초음파의 이용)

  • 조규도;김치경
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1205-1213
    • /
    • 1997
  • This study reviewed useful aspects of the intraoperative transesophageal echocardiography among the patients in whom heart surgery were undertaken between January 1996 and July 1996 at St.Pauls hospital, Medical College of Catholic University, Seoul, Korea. During that period, 61 patients were operated on because of valvular heart disease(25 patients), coronary artery disease(22 patients), congenital heart disease(13 patients), and combined coronary artery disease and valvular heart disease(1 patient). Two patients(1 redo-VSD and 1 valvular heart diease) needed repeated aortic cross clamping and complementary procedures because of incomplete initial procedures. There was no incidence of air embolism. We could observe significant relationship of cardiac output monitoring methods either by thermodilution technique and transesophageal echocardiography by linear regression analysis(p<0.001). We tested myocardial response(percentage of systolic wall thickness, PSWT) with low dose dobutamine challenge to predict post-CABG myocardial perfusion. And the test showed statistically significant resp.onse(sensitivity 76%, specificity 94.7%, positive predictive value 95%, negative predictive value 75%). These results suggest that cardiac surgeon could draw more benefits by intraoperative transesophageal echocardiography.

  • PDF