• 제목/요약/키워드: Output Monitoring

검색결과 594건 처리시간 0.03초

마이크로컨트롤러를 이용한 비상발전계통의 제어장치 개발 (Development of Digital controller for emergency power generating system Using Micro-Controller)

  • 정을기;전희종;손진근;나채동;이성범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.100-102
    • /
    • 2001
  • This paper resents digital controller of emergency power generator system. The controller offers an integrated alternative for Genset control, metering and remote monitoring. Proposed controller used 80c196kc one chip microprocessor for digital control, it measures parameters of generator and provides output signals to control starting and stopping of generator. Additionally protection and alarm functions are considered to system stability. As almost parts of controller are embedded by digital microprocessor and FPGA techniques, the controller has a more flexible feature and an improvement of precision. The developed system has a big merit economically and is suitable for any kW size generator.

  • PDF

휴대용 심박출량 모니터링 시스템의 설계와 알고리듬 연구 (A Study on the Algorithm and Design of Ambulatory Cardiac Output Monitoring System)

  • 송철규;변용훈;김경섭;김남균;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2702-2703
    • /
    • 2002
  • 본 연구에서는 종래의 심박출량 및 일회 심박동량 측정장치를 휴대용 시스템으로 구현하기 위한 회로 설계방법을 연구하였다. 휴대용 시스템의 설계를 위한 아날로그 부분은 인체 안전을 위한 아이솔레이션 증폭기, 변복조기, 0.1Hz 고역통과 필터 및 잡음제거 회로로 구성되며, 연속 심박출량 모니터링 및 연산을 위한 디지탈 부분은 TMS32030C를 이용한 회로로 구성이 된다. 또한 기존의 방법에서의 문제점을 개선하기 위해 연속 심박출량 연산을 위한 새로운 알고리듬을 제안하였다. 제안된 방법은 앙상블 평균시에 기존의 심전도 R피이크 점을 기준으로 하지 않고, 임피던스 신호의 dZ/dt 최대점을 이용하는 방법을 적용하였다. 제안한 심박출량 신호처리 알고리듬을 이용하여 측정된 임피던스 신호를 분석한 결과 최대 25.5 %까지 개선됨을 확인하였다.

  • PDF

Study on the Self Diagnostic Monitoring System for an Air-Operated Valve : Algorithm for Diagnosing Defects

  • Kim Wooshik;Chai Jangbom;Choi Hyunwoo
    • Nuclear Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.219-228
    • /
    • 2004
  • [1] and [2] present an approach to diagnosing possible defects in the mechanical systems of a nuclear power plant. In this paper, by using a fault library as a database and training data, we develop a diagnostic algorithm 1) to decide whether an Air Operated Valve system is sound or not and 2) to identify the defect from which an Air-Operated Valve system suffers, if any. This algorithm is composed of three stages: a neural net stage, a non-neural net stage, and an integration stage. The neural net stage is a simple perceptron, a pattern-recognition module, using a neural net. The non-neural net stage is a simple pattern-matching algorithm, which translates the degree of matching into a corresponding number. The integration stage collects each output and makes a decision. We present a simulation result and confirm that the developed algorithm works accurately, if the input matches one in the database.

AE(acoustic emission)센서를 이용한 공구파손검출에 관한 연구 (A Study of Tool Breakage Dection Using AE Sensor)

  • 이재종;송준엽;박화영
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.61-68
    • /
    • 1989
  • As the system monitoring technology become required in order to improve the system performance and the productivity, we’ve studied to the detection for the tool wear and the tool breakage using AE sensors that is able to detection of generated high frequency stress pulse at cutting. The detection system is consist of a sensing part, a amplifier part, a signal processing part, and a analysis & output part. The moment (a rms and a kurtosis) of statistical method is used for analysis of AE singnal. The experiment are carried out in a CNC lathe. In this study, we achieved that the amplitude level of the AE signal and statistical moments was largely changed as the tool failure. The change rate of Kurtosis was especially large, but the change rate of the rms was small.

  • PDF

Simulation model-based evaluation of a survey program with reference to risk analysis

  • Chang, Ki-Yoon;Pak, Son-Il
    • 대한수의학회지
    • /
    • 제46권2호
    • /
    • pp.159-164
    • /
    • 2006
  • A stochastic simulation model incorporated with Reed-Frost approach was derived for evaluating diagnostic performance of a test used for a screening program of an infectious disease. The Reed-Frost model was used to characterize the within-herd spread of the disease using a hypothetical example. Specifically, simulation model was aimed to estimate the number infected animals in an infected herd, in which imperfect serologic tests are performed on samples taken from herds and to illustrate better interpreting survey results at herd-level when uncertainty inevitably exists. From a risk analysis point of view, model output could be appropriate in developing economic impact assessment models requiring probabilistic estimates of herd-level performance in susceptible populations. The authors emphasize the importance of knowing the herd-level diagnostic performance, especially in performing emergency surveys in which immediate control measures should be taken following the survey. In this context this model could be used in evaluating efficacy of a survey program and monitoring infection status in the area concerned.

Enterohepatic Recycling of Estrogen and its Relevance with Female Fertility

  • Sher, Alam;Rahman, M.Ataur
    • Archives of Pharmacal Research
    • /
    • 제23권5호
    • /
    • pp.513-517
    • /
    • 2000
  • Enterohepatic recycling of estrogen after oral administration of 1 mg non-radioactive estriol was studied in fourteen women selected as the control subjects and ten infertile women in whom the infertility was appearing to be of endocrine origin. The extent of enterohepatic recycling of estriol ($E_3$) during the early follicular phase of menstrual cycle was assessed by monitoring during 48 h the urinary excretion of its two major metabolites i.e; estriol 16 $\alpha$-glucuronide ($E_3-16$$\alpha-G$) and estriol-3 glucuronide ($E_3$-3-G). The change in urinary level of $E_3$-3-G with respect to ($E_3-16$$\alpha-G$G was considered to reflect the extent of enterohepatic recycling of estriol. Lower values of urinary output of both metabolites in the infertile women as compared with the control subjects and the urinary excretion profile of both metabolites during 48 h after estriol ingestion reveal that the reduced extent of enterohepatic recycling could possibly be one of the factors which contribute towards the incidence of infertility in women.

  • PDF

태양광 발전시스템 전지모듈의 온라인 감시 진단 시스템 개발 (On Line Monitoring and Diagnosis Technique for the Array of Photovoltaic Energy System)

  • 이종필;지평식;변상준;임재윤
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.168-172
    • /
    • 2007
  • The global environment deteriorating which originated from using of fossil fuel is an serious problem for human being to solve. The photovoltaic energy has been considered as a solution. In advanced countries, research and development for photovoltaic(PV) energy system is carrying on. Once installed, a PV array requires maintenance and fault diagnosis other than an occasional cleaning. In this research, the proposed system monitor and diagnosis the output of PV array by on-line for maintenance of PV power plant. The validity of proposed system is verified using sample system.

Application of subspace identification on the recorded seismic response data of Pacoima Dam

  • Yu, I-No;Huang, Shieh-Kung;Loh, Kenneth J.;Loh, Chin-Hsiung
    • Structural Monitoring and Maintenance
    • /
    • 제6권4호
    • /
    • pp.347-364
    • /
    • 2019
  • Two seismic response data from the CSMIP strong motion instrumentation of Pacoima dam are selected: San Fernando earthquake (Jan 13, 2001; ML=4.3) and Newhall earthquake (Sept. 1, 2011; ML=4.2), for the identification of the dam system. To consider the spatially nonuniform input ground motion along the dam abutment, the subspace identification technique with multiple-input and multiple-output is used to extract the dynamic behavior of the dam-reservoir interaction system. It is observed that the dam-reservoir interaction is significant from the identification of San Fernando earthquake data. The influence of added mass (from the reservoir) during strong ground motion will create a tuned-mass damper phenomenon on the dam body. The fundamental frequency of the dam will be tuned to two different frequencies but with the same mode shapes. As for the small earthquake event, the dam-reservoir interaction is insignificant.

유비쿼터스 지향의 16채널 스트레인 게이지 계측 시스템 개발 (16 Channel Strain Gauge Measuring Ubiquitous System Development)

  • 장순석;김경석;원용일;김대곤
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.912-917
    • /
    • 2006
  • A strain gauge weight measuring instrumentation system was designed with RF sensor network facilities. In the sensor module system data conversion and a series of signal processing were totally equipped. 16 strain gauges are incoming sensors and each output of the strain gauge was amplified and filtered for proper analog signal processing. Several measuring instrumentation OP amps and general purposed OP amps were used. 12 bits A/D converters converted analog signals to digital bits and a PIC microprocessor controlled the 16 channels of strain gauges. RF RS232 modules were used for wireless communication between the PIC microprocessor and an Ethernet host far a remote sensor monitoring system development.

다기능 산소전극에 의한 산소투과특성 동시측정 (Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode)

  • 이동희;정진휘;유형풍;김태진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF