• 제목/요약/키워드: Outlet valve

Search Result 199, Processing Time 0.025 seconds

Solid Flow Rate and Gas Bypassing with Operating Variables of J-valve in Multistage Annular Type Fluidized Beds (다단 환원형 유동층에서 J-valve의 운전변수에 따른 고체 흐름량 및 기체 우회)

  • Hong, Yoon-Seok;Kang, Gyung-Soo;Park, Joo-Sik;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.62-68
    • /
    • 2011
  • Hydrodynamic characteristics in multistage annular type fluidized bed (riser: $0.01{\times}0.025{\times}2.8m^3$, J-valve: $0.009{\times}0.015m^2$)were investigated. Glass beads ($d_p=101{\mu}m$, ${\rho}_b=1,590kg/m^3$, $U_{mf}=1.25{\times}10^{-2}m/s$, Geldart classification B) was used as a bed material. Accumulated weight by the electronic balance was measured to determine the solid flow rate in batch-type. In circulation condition, we measured the accumulated weight of particle transported from riser. At the steady state condition, solid circulation rate was calculated from time interval of the heated bed material passing between two thermocouples. Solid flow rate increased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 2.2 to 23.4 kg/s. However, mean residence time decreased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 1,438 to 440 s. The solid holdup in the riser was determined by measuring pressure differences according to the riser height. These results showed a similar trend to that of simple exponential decay type except for the top section of the riser. To verify the gas bypassing from top bubbling beds to middle bubbling beds, $CO_2$ gas was injected by tracer gas in constant ratio, and then was measured $CO_2$ concentration in outlet gas by gas chromatography. Gas bypassing occurred below 2.6% which is negligible value.

Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler (핫가스 바이패스 유량에 따른 산업용 냉각기의 온도제어 특성)

  • Baek, Seung-Moon;Choi, Jun-Hyuk;Byun, Jong-Yeong;Moon, Choon-Geun;Lee, Ho-Saeng;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1129-1136
    • /
    • 2009
  • The paper presents the performance characteristics for a cooling system using EEV. The water cooler was used to reduce thermal deformation and contraction due to high speed of machine tools and the EEV was used for capacity control for water cooler. The apparatus was designed for hot-gas bypass system which a hot-gas can flows from outlet of compressor to the inlet of evaporator. This experiment is the intermediary study for precise temperature control through PID control. The results show that the evaporator pressure increased and refrigeration capacity decreased as the EEV opening step of hot-gas bypass increased. These results can be used as basic data for the design of effective water cooler.

A Study on Thermal Management of Stack Supply Gas of Solid Oxide Fuel Cell System for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 시스템의 스택 공급 가스의 열관리 문제에 관한 연구)

  • Park, Sang-Kyun;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.765-772
    • /
    • 2011
  • In this research, the fuel cell system model capable of generating codes in real time was developed to construct of a HIL (Hardware-In-the-Loop) for a SOFC-powered ship. Moreover, the effects of the distribution of the exhaust gas flow rates in a stack, the flow rates of fuels and temperature of air supplied on the temperature characteristics of fuels supplied to the cathode and the anode, the output power of the stack and system efficiency are examined to minimize the temperature difference between fuels supplied to the stack used in a 500kW SOFC system using methane as a fuel. As a result, the temperatures of fuels supplied to the cathode and the anode maintain at 830K when the opening factor of three-way valve located at outlet of turbine is 0.839. Also the process for optimization of methane flow rate considering the fuel cell stack and system efficiency is required to increase the temperatures of fuels supplied to the stack.

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact rats and/or vagotomized rats (정상 및 미주신경절단 흰쥐의 체중, 위액 분비량, 위의 형태변화에 대한 위 유문부 부분폐색과 재개통의 효과)

  • Seon, Jong-Ki;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.26-38
    • /
    • 2012
  • Objectives : The aim of this study was to investigate the effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact and/or vagotomized rats. Methods : Partial pyloric obstruction was performed by wrapping a non-absorbable rubber ring (D:6 mm, W:4 mm, T:1 mm) around the 1st portion of the duodenum. Vagotomy was performed by resecting the branches around the esophagogastric junction. Pre-post body weight differential, fasting gastric juice volume, gastric surface area and gastric edema were measured at 8 weeks and 20 weeks. For the effect of pyloric reperfusion the rubber ring was removed after 8 weeks and then an additional 12 weeks of observation was performed to the end of the 20-week experimental period. Results : In the initial 8 weeks observation, the effect of pylorus obstruction and/or vagotomy was significantly remarkable in the pylorus obstructed and vagotomized group; slowdown of weight gain, increase of fasting gastric juice volume, dilatation of gastric surface area and severe gastric edema were shown. In the remaining 12 weeks observation, the effect of reperfusion was significantly remarkable in the ring-removed antral dilated group; recovery of weight gain, decrease of gastric surface area and decrease of gastric edema were shown. However, gastric juice volume was not significantly different from the other group. Conclusions : Partial pyloric obstruction plays a aggravating role and the vagus nerve plays a protective role in body weight, gastric juice, gastric surface area, and gastric edema. Furthermore, pyloric valve dysfunction as an aggravating factor strengthened in defect of the vagus nerve. These results suggest that patients with both functional pyloric outlet obstruction and hypofunction of vagus nerve need to be diagnosed in good time and treated properly.

Long-term Results Following Surgical Repair of Total Anomalous Pulmonary Venous Return (총폐정맥 환류 이상증에 대한 술후 장기성적 검토)

  • 원태희
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.565-570
    • /
    • 1995
  • Seventy-three patients with isolated total anomalous pulmonary venous connection the patients associated with other major cardiac anomalies such as single ventricle, DORV[Double Outlet Right Ventricle and large VSD[Ventricular Septal Defect were excluded were underwent surgical repair from January 1980 through October 1993. There were 45 boys and 28 girls. The mean age at operation was 19.9 months[range 6 days to 24 years and mean body weight was 7.1kg[range 2.6kg to 45kg . The anomalous locations of connection were supracardiac in 38, cardiac in 21, infracardiac in 5, and mixed in 9. In 38 patients[52% , the venous drainage was obstructed. The obstruction ratios according to the connection type were as follows: 53%[28/38 in supracardiac, 52%[11/21 in cardiac, 100%[5/5 in infracardiac, 22%[2/9 in mixed type. The associated cardiac anomalies were persistent left SVC[2 , tricuspid valve regurgitation[3 , cor triatriatum[1 , and mitral cleft[1 . And associated noncardiac anomalies were imperforate anus[1 and Neil Weightman syndrome[1 . The operative mortality was 23%. The causes of death were pulmonary hypertensive crisis, perioperative myocardial failure, pneumonia with sepsis, arrhythmia and etc. The statistically significant factors in postoperative mortality were the pulmonary venous obstruction and age [p<0.01 . The operative mortality was high in groups of age under 1 month and pulmonary venous obstruction. The mean follow-up was 27.1 months. There were two late deaths. The first patient was three months old boy with supracardiac type and severe obstructive symptoms. The postoperative echocardiography was showed anastomotic stenosis and reoperations were performed twice but the patients expired due to pneumonia and sepsis. The second patient was three month old boy with supracardiac type and total correction was done and was doing well postoperatively. Eight years later, he expired suddenly due to arrhythmia. But all the other patients were in NYHA Fc I and received no medications. The 5-year survival rate excluding early expired patients is 97.1 $\pm$ 0.03 %. In conclusion, although the operative mortality of total anomalous pulmonary venous connection was relatively high compared to other major cardiac anomalies, we could expect excellent long-term results by early surgical correction.

  • PDF

Performance Characteristics of Flooded Type Evaporator for Seawater Cooling System with Heat Source Temperature of Mid-year (중간기 열원수 온도에 따른 만액식 해수냉각시스템의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Lee, Jeong-Mok;Kang, In-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The purpose of this study is to investigate the performance characteristics of seawater cooling system for a fishing vessel. The circulation amount of refrigerant, condensation capacity, evaporation capacity, compression work and coefficient of performance(COP) were analyzed as the heat source temperature changed. The experimental setup consisted of an open-type compressor, a shell&tube type condenser, an evaporator and an expansion valve. The heat source was controlled by a constant temperature chamber. The main results of this study are summarized as follows. The condensation capacity increased with increasing heat source temperature, and it was confirmed that the effect of circulating amount of refrigerant was dominant. The amount of heat for vaporization was almost constant even though the temperature of the heat source increased. On the other hand, the compression power was increased. This is because the compression ratio increases as the condensation pressure, the enthalpy difference between inlet and outlet, the amount of circulating refrigerant increases. The performance coefficient of this system showed a tendency decreasing with increasing heat source temperature. Therefore, the basic data of the seawater cooling system for the maintenance of the catch line of the shore fishing boats was acquired through this study, and it is considered that it will be sufficient for the actual design.

Investigation of right ventricle function in patients with tetralogy of Fallot after total correction using cardiac magnetic resonance imaging (심장 자기공명영상을 이용한 팔로사징 완전 교정술 후 우심실 기능에 대한 연구)

  • Jang, Woo Sung;Choi, Hee Joung;Lee, Jong-Min;Kim, Jae Bum;Kim, Jae Hyun;Jang, Jae Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.238-241
    • /
    • 2017
  • Background: We investigated the difference in right ventricle (RV) volume and ejection fraction (EF) according to the pulmonary valve (PV) annular extension technique during Tetralogy of Fallot (TOF) total correction. Methods: We divided patients who underwent the procedure from 1993 to 2003 into two groups according to PV extension technique (group I: PV annular extension, group II: no PV annular extension) during TOF total correction. We then analyzed the three segmental (RV inlet, trabecular and outlet) and whole RV volume and EF by cardiac magnetic resonance imaging (MRI). Results: Fourteen patients were included in this study (group I: 10 patients, group II: four patients; male: nine patients, female: five patients). Cardiac MRI was conducted after a 16.1 years TOF total correction follow-up period. There was no statistical difference in RV segmental volume index or EF between groups (all p>0.05). Moreover, the total RV volume index and EF did not differ significantly between groups (all p>0.05). Conclusion: The RV volume and EF of the PV annular extension group did not differ from that of the PV annular extension group. Thus, PV annular preservation technique did not show the surgical advantage compared to PV annular extension technique in this study.

Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control (PI와 피드포워드 제어를 이용한 공작기계용 오일쿨러의 핫가스 바이패스 방식 정밀 온도 제어)

  • Jeong, Seok-Kwon;Byun, Jong-Yeong;Kim, Sang-Ho;Yoon, Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-119
    • /
    • 2011
  • Recently, the performances of speed and accuracy are enhanced in machine tools. The high speed of the machine tools usually causes harmful thermal displacements on the objects. To reduce the thermal displacements, machine tools generally adopt oil coolers with precise temperature control function. This study aims at precise control of oil outlet temperature in the oil coolers with hot-gas bypass manner based on PI control logic. The control system was designed for obtaining steady state error within ${\pm}0.1^{\circ}C$ and maximum overshoot with 0.8% even though abrupt disturbances are added to the system. We showed that the PI gains could be easily decided by numerical simulations using practical transfer function which got experiments. Also, transient characteristics could be improved significantly by reflecting the inlet temperature of an evaporator to the output of a controller feedforwardly considering periodic abrupt disturbances. Through some experiments, excellent control performances were established by the suggested control.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station(I) - Flow Analysis and Mass Flow Rate Verification of Pressure Regulator - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석(I) - 정압기 유동 해석 및 질량 유량 검증 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 2008
  • Gas pressure regulators in pressure regulating station reduce high-pressure gas in a process line to a lower. Gas pressure regulators are not flow control devices, they are used to control delivery pressure only. For the safety of pressure regulating station, it is essential to study flow regime and characteristics of a safety valves that is connected to a pressure regulator. For this, it is necessary to understand flow characteristics and the flow rate of upstream component part such as gas pressure regulators in regulating station. In the present study, numerical analysis of flow characteristics and the mass flow rate of a pressure regulator is conducted under the several inlet, outlet conditions and open rates. Then, the numerical result of the mass flow rate is verified with experimental equation from manufacture of pressure regulator. Consequently, the numerical result is comparatively good agreement with values from experimental equation.

  • PDF