• Title/Summary/Keyword: Outlet Valve

Search Result 199, Processing Time 0.039 seconds

Effect of Reynolds Number on the Flow Characteristics of a Control Valve (제어밸브 유량특성에 레이놀즈 수가 미치는 영향)

  • Jung, Taekyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.995-999
    • /
    • 2017
  • The factors affecting the flow coefficient of a control valve were identified and analyzed. The flow coefficient of a control valve are affected by not only Reynolds Number but also the figure and the roughness of the inlet/outlet pipes. Therefore, the flow coefficient is not a constant value. For the purpose of use in the system such as LRE, requiring the exact flow-coefficient of a control valve, the flow-coefficient should be measured under similar Reynolds Number using the inlet and outlet pipes which have the same figure and roughness with a real system.

  • PDF

A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve (상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구)

  • Tea-Joon Kim;Chung-Seob Yi;Chi-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.307-313
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.

Lip Type Electromagnetic Flap Valve for Low Leakage (누수 최소화를 위한 립 타입 전자력 플랩 밸브)

  • Lim, In-Ho;Lee, Ki-Jung;Sim, Woo-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1476-1477
    • /
    • 2008
  • This paper reports on a flexible flap valve actuated by electromagnetic force under a constant pressure source. The flexible flap valve consists of the three main components: a flexible flap with a steel disk embedded in PDMS, an electromagnetic actuator and two glass plates with inlet and outlet. Sealing lip structures for improving the valve characteristics are added on the outlet of the bottom glass substrate. The flap valve is fabricated by the spin-coating process, the EDM process, SU-8 mold process and oxygen plasma treatment. The dimension of an assembled flap valve is $12mm{\times}20mm{\times}28mm$. The stroke volume of the flap valve is measured for various pressures and open times. When the input voltage of 30 V is applied for 0.33 s, the minimum stroke volume of the flap valve is 70 ${\mu}L$ at 50 kPa.

  • PDF

Double-Outlet of Left Ventricle in Corrected Transposition of Great Arteries -One case report- (좌심실 이중유출로를 동반한 교정형 대혈관전위증 -1예보고-)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.119-126
    • /
    • 1979
  • This is one case report of the extremely rare congenital cardiac malformation, Double-outlet of left ventricle in corrected transposition of great arteries. 11-year-old boy complained acrocyanosis and exertional dyspnea, the parents noticed cyanosis since birth. Physical examination revealed acrocyanosis, clubbed fingers and toes, G-III pansystolic murmur on 2nd and 3rd ICS, LSB. Right heart catheterization revealed significant $O_2$ jump in ventricular level. Right and left ventriculography showed the both catheters arriving in the same ventricle i.e. anterior chamber, morphological left ventricle was in right and anterior position, simultaneous visualization of aorta and pulmonary artery and aorta locating anterior and right side of pulmonary artery. Echo cardiogram surely disclosed interventricular septum. Conclusively it was clarified that the patient has Double-outlet of left ventricle and corrected transposition of great arteries [S.L.D.]. Operation was performed to correct the anomalies under extracorporeal circulation with intermittent moderate hypothermia. Right-sided ventriculotomy disclosed the following findings. 1. Right-sided ventricle was morphological left ventricle. 2. Left-sided ventricle was morphological right ventricle. 3. Right side atrioventricular valve was bicuspid. 4. Left side atrioventricular valve was tricuspid. 5. Aortic valve was superior, anterior and right side of pulmonary valve. 6. Subpulmonary membranous stenosis. 7. Non-committed ventricular septal defect. We made a tunnel between VSD and aorta with Teflon patch so that arterial blood comes through VSD and the tunnel into aorta. After correction the patient needed assisted circulation for 135 min. to have adequate blood pressure. Postoperatively by any means, adequate blood pressure could not be maintained and expired in the evening of operation day.

  • PDF

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.

The Effect of In-Outlet Differential Pressure on a Valve Body Stress and Deformation by the Blow-by Gas Flow Characteristic in the PCV valve for Automobile (자동차용 PCV밸브내 유통특성에 의한 밸브응력 및 변형에 미치는 입출구 차압의 영향)

  • Kwon Oh-Heon;Lee Yeon-Won;Song Sang-Min;Lee Jong-Hoon;Kang Ji-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.36-41
    • /
    • 2005
  • PCV(Positive Crankcase Ventilation) valve acts as a flow control valve to get a re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. The blow-by gas of the crankcase should be eliminated or taken properly because it cause corrosion to critical parts, and contributes to increase crankcase pressure that can cause a drop in efficiency. The excessive stress and strain on the PCV valve that remove these harmful gas would be bring the difficult on the flow rate control and failure of the valve. Those condition inevitably induce the accident. Therefore, this study purpose is FEM evaluation of the stresses and deformation in the X3 PCV model according to the change of the differential pressure between inlet and outlet. From results, the maximum equivalent stresses increased linearly according to the increase of the differential pressure at the about 50mm from the inlet position and were under the yield strength of the valve. And the deformations were relatively small regardless of the in-outlet differential pressure variation.

Flow Analysis of Servo Valve (Servo valve의 유동해석)

  • Park, Hong-Beom;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1221-1225
    • /
    • 2008
  • In this paper, analysis of pressure and flow characteristics have been performed with a servo valve. A number of servo valve have been used in various applications including the inserting device, bearing transportation and welding machine. By analysis of flow and pressure gradient, technology can be obtained about optimal simulation of high response servo valve for competitiveness. Spool displacement and ratio of inlet/outlet pressure can give big effects to flow and pressure inside servo valve.

  • PDF

The Design and Analysis of vacuum Pump Driven by Linear Motor (리니어 모터구동 진공펌프 설계 및 해석)

  • 김동수;안영희;이원희;김광영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.680-683
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of vacuum pump driven by linear motor. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve when spring farce (14.8N) is exerted. The results of simulation. it was turned out that reached vacuum pressure was about -0.55 bar at 150 seconds, magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF

A Study on the Control Characteristics of FHA by Using PLC (PLC를 이용한 ER밸브-FHA의 제어특성에 관한 연구)

  • Jang, Sung-Cheol;Hong, Soon-Nam
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.331-336
    • /
    • 2013
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. As the strength of the electric field increases, more clusters in flow are made and these clusters are thought to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system. Using the manufactured pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller(PLC).

Design and Analysis of Linear Motor for Medical Appliance Pump (의료용 펌프의 리니어 모터 설계 및 해석)

  • Kim, Dong-Soo;Lee, Won-Hee;Park, Jae-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2683-2686
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of linear motor for medical appliances. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve, when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve, when spring force (14.8N) is exerted. The results of simulation, it was turned out that magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF