• 제목/요약/키워드: Outlet Valve

검색결과 199건 처리시간 0.025초

마이크로 정량펌프의 유동해석과 작동성능 평가 (The Flow Analysis and Evaluation of the Peristaltic Micropump)

  • 박대섭;최종필;김병희;장인배;김헌영
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

The Pumping Characteristics of the Valveless Peristaltic Micropump by the Variation of Design Parameters

  • Chang, In-Bae;Park, Dae-Seob;Kim, Byeng-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.101-109
    • /
    • 2002
  • This paper presents the fabrication and performance inspection of a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of base plate, mid plate, top plate and connection tubes fur inlet and outlet. In detail, the base plate is composed of two diffuser nozzles and three chambers, the mid plate consists of a glass diaphragm for the volumetric change of the pumping chamber. The inlet and outlet tubes are connected at the top plate and the actuator fur pressing the diaphragm is located beneath the top plate. The micropump is fabricated on the silicon wafer by DRIE (Deep Reactive ion Etching) process. The pumping performances are tested by the pneumatic test rig and compared with the simulated results fur various dimensions of diffuser nozzles. The pumping characteristics of the micropump by the volumetric change at the pumping chamber is modeled and simulated by the commercial software of FLOW-3D. The simulated results shows that reverse flow is the inherent phenomena in the diffuser nozzle type micropump, but it can be reduced at the dual pumping chamber model.

R245fa 냉매를 이용한 배열회수 히트펌프 시스템 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Recovery Heat Pump System using R245fa Refrigerant)

  • 김현택;김용찬;차동안;권오경
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.408-413
    • /
    • 2016
  • The objective of this study is to investigate the performance of a heat recovery heat pump dryer using a R245fa refrigerant experimentally. In this study, the main components of the heat pump dryer were an evaporator, a compressor, a condenser, and an expansion valve. As a result, when the amount of refrigerant varied from 15 kg to 16 kg, the hot air outlet temperature in the condenser and the heat transfer rate were almost kept constant. Therefore, the amount of refrigerant at 16 kg was considered to be a suitable amount in the heat pump. As the air inlet velocity varied from 0.5 m/s to 1.5 m/s, the highest temperature in the condenser could be obtained when the air inlet velocity was 0.5 m/s. The heat transfer rate, system (COP), and hot air outlet temperature were 5.6 kW, 3.4, and $102.5^{\circ}C$, respectively, when the bypass ratio and water temperature were 0% and $60^{\circ}C$.

대혈관 변위를 동반한 선천성 복잡심기형에 대한 동맥전환술 (Arterial switch operation for the complex congenital heart anomalies with malposition of the great arteries)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • 제26권1호
    • /
    • pp.36-43
    • /
    • 1993
  • Sixty four children [aged 2 days to 9 years] , 58 with complete transposition of the great arteries, 5 with Taussig-Bing double outlet right ventricle, and 1 with double outlet left ventricle plus left ventricular type single ventricle, have undergone anatomic correction from November 1987 to August 1992. Eleven underwent previous operations: pulmonary artery banding[7], modified Blalock-Taussig shunt[2], coarctoplasty[2], aortic arch reconstruction[1] . Of 58 patients with TGA, Type A coronary arteries of Yacoub were seen in 50[86%]. U-shaped coroanry arterial flaps were transfered to the neoaorta using trap door technique, and neopulmonary arterial tract was constructed using glutaraldehyde fixed autopericardium with Lecompte maneuver. There were 18 hospital deaths [28.1%] with no late mortality. Mean follow-up of 20.4\ulcorner11.9 months were achieved in all survivors. Postoperative cardiac catheterizations were done in 14 cases. Mean pressure gradients of pulmonary and aortic outflow tract were 15.0 $\pm$2.6 and 4.2$\pm$1.4mmHg, mild aortic valve insufficiencies were found in 2, and mean cardiac index was 5.18$\pm$0.19 L/min/M2. We conclude that we should continue anatomic correction for the complex congenital heart anomalies with the malposition of the great arteries because myocardial function seems to be well preserved, though we are still on the learning curve.

  • PDF

맥동압을 가지는 챔버내의 압력변화에 관한 연구 (Study on the Pressure Variation in a Chamber Caused by Pulsation Pressure)

  • 이중섭;심규진;;정한식;정효민
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.132-138
    • /
    • 2007
  • Experimental results of pulsating pressure behavior inside a chamber have been confirmed by computational work. Inside-cylinder pressure shows unstable condition at low rpm. This is caused by plate-type suction valve. It has effect up to inlet of the chamber. But trembling phenomenon is reduced as the pressure is enlarged by increasing the rpm. Result comparison between experimental and numerical analysis shows pulsation reduction is affected by the chamber. We can confirm that compressible effect of the working flow is shown at chamber inlet by increasing rpm. On the other side, this effect is declined at chamber outlet by increasing rpm. It means outlet pressure is going on balance with atmosphere pressure. Buffer plate-type chamber has efficiency of pulsation flow reduction.

흡배기구 직결회로를 이용한 공압 서보장치의 개발과 집게 시스템용 퍼지제어기 설계 (Development of a Pneumatic Servomechanism Using a Direct-connected Circuit between Inlet and Outlet and Its Application to the Design of a Fuzzy Position Controller for a Fingering System)

  • 최갑용;최인수
    • 대한산업공학회지
    • /
    • 제21권4호
    • /
    • pp.593-608
    • /
    • 1995
  • In this study two issues are considered, one is to develop a pneumatic servomechanism using a direct-connected circuit between inlet and outlet, the other is to design two kinds of advanced controllers such as fuzzy and PID controllers for a fingering system. Besides, the application of the advanced controllers to the newly proposed servomechanism is presented. The procedure of this study is composed of following 6 steps : [Step 1] Structuring of a control system; [Step 2] Development of a pneumatic circuit for the servomechanism ; [Step 3] Characteristic analysis of the valve and cylinder systems ; [Step 4] Determination of optimal parameters of the PID controller ; [Step 5] Design of a fuzzy controller and parameter tuning; and, [Step 6] Experimental analysis of fuzzy and PID controllers. Experimental results show that the newly proposed pneumatic servomechanism has good performance and, not only the performance of the fuzzy controller is better than that of the PID controller but also the fuzzy controller fits well to the control of the pneumatic servomechanism.

  • PDF

전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구 (FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement)

  • 손원식;송재욱;전완재;김승모
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.175-181
    • /
    • 2019
  • 수소연료전지차(FCEV)의 수소연료 공급시스템에서 대용량 감압에 사용되는 기존의 1단 감압 구조 레귤레이터(Regulator)의 경우 높은 감압에 따른 맥동과 느린 응답, 수소 취성, 누설, 고중량, 고비용 등의 문제점이 있다. 이러한 문제점은 2번에 걸친 감압 메커니즘(2단 구조)을 가지는 2단 레귤레이터 개발을 통해 극복될 수 있으며, 2번째 감압시점에 전자식 솔레노이드 밸브를 적용한다면 폭넓은 출구압력의 제어가 가능하다. 이에 따라 2단 전자식 솔레노이드 밸브를 가지는 레귤레이터의 출구압력 정밀도 향상과 누설방지, 내구성, 경량화, 가격저감 등의 기술개발이 필요한 실정이다. 이중에서도 레귤레이터의 필수적인 성능인 출구압력 정밀도 향상과 누설 방지를 위해 감압 전과 감압 후의 구조부분을 나누어 각각의 초기 내압 적용 후 Valve part가 닫힌 상태(Open Ratio : 0 %)로 가정하여 해석 연구를 진행하였다. 1차감압부의 기밀성과 관련하여 Aluminum Alloy 소재의 사용은 부적절하다고 판단되었고, 서로 다른 금속으로 구성되었을 때는 응력의 변화와 함께 변위 또한 같이 증가하므로 이종 소재를 사용하는 접촉부 구성은 부적절하다고 판단되었다. 2차 감압부의 기밀성과 관련된 변위 측면에서는 Young's Modulus 값이 큰 TPU(Thermoplastic Polyurethane)를 사용하는 것이 비교적 변위량이 작으므로 적절하다고 판단하였고, 기밀성에 대한 기준으로 Case 분석을 진행한 결과 최적 형상을 설계할 수 있었다.

열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험) (Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment))

  • 이욱재;홍희기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

터보펌프-가스발생기 연계시험의 모드 변환 중간 작동점 분석 (Analysis for Operation Point Change in Mode Transition at the Turbopump-Gas Generator Coupled Test)

  • 남창호;김승한;박순영;김철웅
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.43-50
    • /
    • 2009
  • 터보펌프-가스발생기 연계시험에서 작동점 변경을 위해 거치는 중간 작동점의 특성을 시스템 모사 프로그램으로 검토하였다. 중간 작동점에서 펌프 토출압, 가스발생기 혼합비, 가스발생기 온도, 가스발생기 압력 등의 변수를 안전한 시험기 운용을 고려하여 검토하였다. 터보펌프-가스발생기 연계시험기와 엔진시스템을 비교한 결과 중간 작동점이 차이는 작지만 서로 다르고 이는 엔진 시스템에서 연소기 유량에 따른 연소압 변화가 발생하기 때문이다. 연소기 배관의 밸브 변경을 우선할 때 중간 작동점이 보다 안전한 영역에 위치한다.

좌심방 양심실 연결증 [DOLA] (Double Outlet Left Atrium: A rare form of the atrioventricular septal defect with malposition of the atrial septum)

  • 이재원;서경필
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.273-278
    • /
    • 1985
  • The case of a patient with abnormal position of the atrial septum resulting in a left atrium with two atrioventricular valves and a disconnected right atrium is presented with review of related articles. Anatomic details showed atrial situs solitus and a left sided cardiac apex. The right atrium received both venae cavae and a coronary sinus. No AV valve was found in the right atrium, and the floor of this chamber was placed above the posterior wall of right ventricular chamber. The atrial septum with secundum ASD was displaced to right anteriorly at its lower portion and inserted to right of tricuspid annulus. The tricuspid and mitral valve configuration was that of so-called partial ECD, i.e. mitral cleft with large anterior mitral leaflets. The ventricular septum was intact and both ventricular chambers were equally well developed with normal relationships. Surgical repair of this anomaly was performed by resecting the abnormally positioned lower part of the atrial septum, repairing the cleft of the anterior mitral leaflet, and septating the atrium for diverting the systemic and pulmonary venous blood to RV and LV, respectively.

  • PDF