• Title/Summary/Keyword: Outlet Mass Flow

Search Result 175, Processing Time 0.027 seconds

Modeling and Parameter Identification of Coal Mill

  • Shin, Hwi-Beom;Li, Xin-Lan;Jeong, In-Young;Park, Jong-Man;Lee, Soon-Young
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.700-707
    • /
    • 2009
  • The coal mill used in the coal-fired power plants is modeled in view of the controller design rather than the educational simulator. The coal mass flow and the outlet temperature are modeled by reinvestigating the mass balance and heat balance models physically. The archived data from a plant database are utilized to identify the model parameters. It can be seen that the simulated model outputs are well matched with the measured ones. It is also expected that the proposed model is useful for the controller design.

Combustion Characteristics of Fuel-rich Gas Generator with Impinging Injector for a Liquid Rocket Engine (액체로켓엔진에서 충돌형 분사기 형태의 연료과잉 가스발생기 연소특성)

  • Han, Yeoung-Min;Kim, Seung-Han;Lee, Kwang-Jin;Moon, Il-Yoon;Seol, Woo-Seok;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.64-70
    • /
    • 2005
  • The overall results of hot firing tests of fuel-rich gas generator with impinging injector at design and off-design points are described. The gas generator consists of an injector head with impinging injector, a water cooled combustor wall, a turbulence ring to enhance mixing, an instrument ring measuring temperature and pressure and a nozzle. The combustion tests were successfully performed without damage of gas generator. Test results show that the outlet temperature is not dependent on residence time of hot gas within 4~6msec but dependent on chamber pressure. The relation between outlet temperature and combustion efficiency resulting from measured pressure, mass flow rate and area of nozzle throat is shown. The overall O/F ratio is the critical parameter to determine the outlet temperature and the linear correlation between two parameters is established.

Modeling of Hydrogen Recirculation System for Fuel Cell Vehicle (수소 연료전지차의 재순환시스템 모델링 연구)

  • Kim, Jae-Hoon;Noh, Young-Gyu;Jeon, Ui-Sik;Lee, Jong-Hyun
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.4
    • /
    • pp.481-487
    • /
    • 2011
  • A fuel cell vehicle using a polymer electrolyte membrane fuel cell (PEM FC) as power source produces electric power by consuming the fuel, hydrogen. The unconsumed hydrogen is recirculated and reused to gain higer stack efficiency and to maintain the humidity in the anode side of the stack. So it is needed considering fuel efficiency to recirculated hydrogen. In this study, the indirect hydrogen recirculation flow rate measurement method for fuel cell vehicle is presented. By modeling of a convergent nozzle ejector and a hydrogen recirculation blower for the hydrogen recirculation of a PEM FC, the hydrogen recirculation flow rate was calculated by means of the mass balance and heat balance at Anode In/Outlet.

A Study on the Noise Produced by Unsteady Exhaust Efflux of Engine (기관의 비정상 배기배출에 의해 생성되는 소음에 관한 연구)

  • 이민호;박명규
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.191-200
    • /
    • 1997
  • This paper discusses prediction of the sound pressure level produced by simple engine exhaust systems(plain pipe, plain expansion chamber pipe, plain expansion chamber with internally extended inlet and outlet pipe, perforated pipe enclosed in a plain expansion chamber) and a computer program has been developed which predicts the sound pressure level and the frequency spectrum. The program utilizes unsteady flow gas dynamic theory and acoustic theory to predict the pressure-time history in the exhaust system and the mass flow rate-time history at the open end of the system and the sound pressure levels(1/3 Octave band levels) and the frequency spectrum in semi-anechoic room. The predictions are compared with measured levels and show a high degree of correlation.

  • PDF

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열교환 성능 분석(농업시설))

  • 서원명;강종국;윤용철;김정섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

A Study on Performance Analysis of the Bubble Pump in Solar Water Heater System (태양열 온수기 시스템에 적용된 기포펌프의 성능평가에 대한 연구)

  • Lee, Kwang-Sung;Li, Xuesong;Jin, Zhenhua;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2310-2315
    • /
    • 2008
  • In this paper, study on performance analysis of bubble pump on the domestic solar water heater system is presented. Device of this experiment is consisted of bubble pump, solar collector and heat exchanger. At the mean time, this system have attached temperature sensors and pressure sensors at bubble pump. In addition, the flow meter was installed at outlet of heat exchanger. And then result of experimental study, average value of the heat exchange amount in heat exchanger was about 7.9kcal/hr, the maximum value of the heat amount in water tank($0.4m^3$) was 489.7kcal/hr and the maximum value of the mass flow rate in bubble pump was about $0.5{\ell}/min$.

  • PDF

Experimental Study on the Performance of Refrigeration System with an Ejector

  • Lee, Won-Hee;Kim, Yoon-Jo;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.201-210
    • /
    • 2002
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were peformed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one of the evaporators) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flow rate ratio of suction fluid to motive fluid increases. The COP of dual-evapo-rator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger (Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구)

  • ANCHEOL CHOI;SEONGWOO LEE;IK HO SHIN;SUNGWOONG CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.