• Title/Summary/Keyword: Outdoor structure

Search Result 234, Processing Time 0.022 seconds

Exploring an Instrumental Measurement of Quality of Housing Environment (주거환경의 질 척도에 관한 연구)

  • 박정희
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.71-84
    • /
    • 1994
  • This article tries to develop an instrument for assessing the quality of housing environment by using 67 housing environment variables. The method of factor analysis is used to explore the dimension of the quality of housing. As the result, 5 dimensions of housing environment are extracted. They are, according to the order of their importances, house structure and indoor environment, outdoor facilities and natural environment, indoor facilities and economy, public facilities and social relationship, and convenient facilities and residential feasibility.

  • PDF

Accuracy Comparison Between Image-based 3D Reconstruction Technique and Terrestrial LiDAR for As-built BIM of Outdoor Structures

  • Lee, Jisang;Hong, Seunghwan;Cho, Hanjin;Park, Ilsuk;Cho, Hyoungsig;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.6
    • /
    • pp.557-567
    • /
    • 2015
  • With the increasing demands of 3D spatial information in urban environment, the importance of point clouds generation techniques have been increased. In particular, for as-built BIM, the point clouds with the high accuracy and density is required to describe the detail information of building components. Since the terrestrial LiDAR has high performance in terms of accuracy and point density, it has been widely used for as-built 3D modelling. However, the high cost of devices is obstacle for general uses, and the image-based 3D reconstruction technique is being a new attraction as an alternative solution. This paper compares the image-based 3D reconstruction technique and the terrestrial LiDAR in point of establishing the as-built BIM of outdoor structures. The point clouds generated from the image-based 3D reconstruction technique could roughly present the 3D shape of a building, but could not precisely express detail information, such as windows, doors and a roof of building. There were 13.2~28.9 cm of RMSE between the terrestrial LiDAR scanning data and the point clouds, which generated from smartphone and DSLR camera images. In conclusion, the results demonstrate that the image-based 3D reconstruction can be used in drawing building footprint and wireframe, and the terrestrial LiDAR is suitable for detail 3D outdoor modeling.

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

Prediction of temperature distribution in PV module using finite element method (유한 요소 해석 프로그램을 이용한 모듈 내 온도 분포 예측)

  • Park, Young-Eun;Jung, Tae-Hee;Go, Seok-Hwan;Ju, Young-Chul;Kim, Jun-Tae;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • PV module is installed in various outdoor conditions such as solar irradiation, ambient temperature, wind speed and etc. Increase in solar cell temperature within PV module aggravates the behaviour and durability of PV module. It is difficult to measure temperature among respective PV module components during PV module operating, because the temperature within PV module depends on thermal characteristics of PV module components materials as well as operating conditions such as irradiation, outdoor temperature, wind etc. In this paper, simulation by using finite element method is conducted to predict the temperature of each components within PV module installed to outdoor circumstance. PV module structure based on conventional crystalline Si module is designed and the measured values of thickness and thermal parameters of component materials are used. The validation of simulation model is confirmed by comparing the calculated results with the measured temperatures data of PV module. The simulation model is also applied to estimate the thermal radiation of PV module by front glass and back sheet.

A Study on the Site Planning of an Apartment Complex for Improving the Outdoor and Indoor Air Quality (아파트의 실내외 공기질 향상을 위한 주동 배치 계획 연구)

  • Shin, Jee-Woong;Kim, Tae-Yeon;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.195-202
    • /
    • 2004
  • This study focuses on the impacts of apartment building arrangements on the outdoor and indoor air quality - the efficiency of natural ventilation in the outside/inside area of an apartment with consideration to the characteristics of an air flow in outside area depending on the types of the arrangements, the main direction of the wind, and the outside wind pressure on the building facade. As indices to evaluate the efficiency of natural ventilation, the concepts of "Age of Air" and "Purging Flow Rate(PFR)" were used in this study. As indices to classify the efficiency of indoor natural ventilation, the mean values of the wind pressure differences between the front and the back elevations of an apartment building were used. The research showed that the PFR of each apartment building arrangement ranges from 0.867 to 3.253. The "minus-shaped" arrangement showed the highest PFR, 2.306; the "zigzag-shaped" arrangement measured 1.889; the "angle-shaped" arrangement measured 1.465, and the "square-shaped" arrangement measured 1.241. Depending on the direction of the wind, the pressure differences range extremely, with variations from 170% to 2300%. Thus, the indoor natural ventilation efficiency can be changed by the pressure differences of the wind, which are sensitive to the main direction of the wind even though the structure and planning of the apartment complexes are the same. Despite the same direction of the wind, even the efficiency can be diverse. This study showed how to predict the most beneficial apartment building arrangement for the profitable natural ventilation efficiency in each direction of the wind.

Analysis of Temperature and Power Generation Characteristics of Bifacial BIPV System Applied into Curtain Wall (양면형 BIPV 시스템의 커튼월 적용에 따른 온도 및 발전특성 분석)

  • Kang, Jun-Gu;Kim, Yong-Jae;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.57-66
    • /
    • 2015
  • BIPV system not only produces electricity at building, but also acts as a material for building envelope. Thus, it can increase the economical efficiency of PV system by saving the cost for building materials. Bifacial solar cell can convert solar energy to electrical energy from both sides of the cell. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial solar cells. Therefore, many of the module manufacturers can easily use the bifacial solar cells without changing their manufacturing equipments. Moreover, bifacial PV system has much potential in building application by utilizing glass-to-glass structure of PV module. However, the electrical generation of the bifacial PV module depends on the characteristics of the building surface which faces the module, as well as outdoor environment. Therefore, in order to apply the bifacial PV module to building envelope as BIPV system, its power generation characteristics are carefully evaluated. For this purpose this study focused on the electrical performance of the bifacial BIPV system through the comparative outdoor experiments. As a result, the power generation performance of the bifacial BIPV system was improved by up to 21% compared to that of the monofacial BIPV system. Therefore, it is claimed that the bifacial BIPV system can replace the conventional BIPV system to improve the PV power generation in buildings.

A Change of Surface Structure with Insulation Cover and Outdoor Cross-linked Polyethylene Insulated Wire Degraded by Salt Water (염수에 의해 열화된 절연커버 및 옥외용 가교폴리에틸렌 절연전선의 표면구조변화)

  • Choi, Chung-Seog;Gil, Hyoung-Jun;Kim, Hyang-Kon;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1897-1899
    • /
    • 2004
  • In this paper, in order to analyze the characteristics of degradation by salt water with insulation cover and OC wire(outdoor cross-linked polyethylene insulated wire) used in power receiving system, an experimental apparatus has been designed and fabricated. An insulation cover and OC wire were installed in an experimental apparatus, and degraded in each case of 2%, 5%, 10% salinity during 12 weeks. An optical microscope was used to observe a changing process of sample surface, and an electrical safety was analyzed by measuring dielectric breakdown voltages of samples. As salinity increased, so ununiformity of sample surface increased. The breakdown wasn't produced to 50kV about samples regardless of salinity, testing period.

  • PDF

Developing organizational system for safety management of sport facilities: Focusing on cases in Japan and Germany

  • Seo, Won-Jae;Park, Seong-Hee;Kim, Nam-Su;Moon, Bo-Ra;Han, Seung-JIn
    • Journal of Sport and Applied Science
    • /
    • v.2 no.1
    • /
    • pp.11-23
    • /
    • 2018
  • In spite of importance of safety issues in community sport, little concerns have been paid to the sport safety policy. Governing bodies and individuals involved with the facility management have a responsibility to manage the risks at acceptable levels. For sports injury prevention interventions, the safety policy of sport facilities should be made to provide a structured framework which can be implemented at community sport. Hence, the current study is to identify the safety issues and to generate the policies that assist to conduct the systematic safety management at sports facilities. For this, the current study analyzed two cases from Japan and Germany. The study reviewed multiple pieces of literature including journal publications, political reports, and media coverage. Through review, the study analyzed the organizational structure, legal systems, and political stance of the safety management of sport facilities in Japan and Germany. The results proposed the following issues. First, law needs to be enacted to establish the control tower where has a responsibility to develop the safety manual and system. Second, local organizations need to be established to educate individuals working in sport facilities and inspect the facilities. Further political issues were discussed for safety management in Korea sport facilities.

An Empirical Study on Public Child Care Center for the Necessity of the Eco-Environmental Space (친환경공간의 필요성에 따른 구립 어린이집의 사례 연구)

  • Han, Hae-Ryon;Park, Young-Ki
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.91-94
    • /
    • 2007
  • The change of modern society arouse the issue of the family structure and the demand of upbringing. According to the issue, the need of the upbringing is the big interest in society. This study is on the necessity of the eco-environmental space in public child care center. The study progressed with the result of the prior study, the demand of the parents of students in eco-environmental space in child care center. The results of the study are first, the natural light source can import in sky light, side light and atrium in child care center. Second, the indoor garden and interior plants would give the natural feelings. Third, the ponds and waterways in indoor and outdoor would give the empirical experiences. And the last, the stone and clay would give the tender feelings in interior and the sand play in outdoor would give the activities. This study would be the foundation on the upcoming study of the needs of the eco-environmental spaces in child facilities.

  • PDF

The erosion factor of silicone rubber for outdoor use (옥외용 실리콘 고무의 침식요인에 관한 연구)

  • 서광석;김정호;이호열;박용관;양계준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.117-120
    • /
    • 1998
  • It is analyzed the erosing process of the polymeric insulator for outdoor use with the inclined plane method. Materials used are the different type of silicone rubber, they have the content of filler and component each other. As the content of filler added to improve the tracking and erosion resistance. It has the difference of electrical performance and erosion rate. The dry-band arc is also the parameter of accelerating erosion, and appear in the form of leakage current, and the activities of leakage current has a close relationship with the surface hydrophobicity. In this paper, the erosion growth is observed by measuring the time from the voltage application to the whole breakdown, and the erosion depth. In addition, it is measured the hydrophobicity and leakage current to be a cause of erosion by the erosion steps, studied SEM, EDX for observing the transformation of surface structure by erosing.

  • PDF