• Title/Summary/Keyword: Outdoor storage

Search Result 88, Processing Time 0.026 seconds

A Study on the Fire Impact of Adjacent Storage at Outdoor Storage Fire (옥외저장소 화재 시 인접 저장소 화재 영향에 대한 연구)

  • Eun-Ji Kim;Sung-Seek Park;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.93-100
    • /
    • 2024
  • Outdoor storage fires have a significant impact on the surrounding environment, including adjacent storage facilities and buildings. Therefore, it is essential to review and manage the fire impact to minimize damage to human life and property on the outdoor storage fires. In this study, the heat release rate and radiant heat flux were simulated according to the fire time, wind veolcity, and presence or absence of water spray equipment in an outdoor storage facility fire, and the fire impact was analyzed. The outdoor storage was designed to simulate two scenarios on the outdoor storage fires containing gasoline, and FDS was used for fire simulation. As a results, when the water spray facility was not operating and the wind velocity was 5 m/s, the maximum radiant heat flux was 24.80 kW/m2, which exceeded the limit radiant heat flux of 20 kW/m2. When the water spray facility was operating and the wind veolcity was 10 m/s, the maximum radiant heat flux was 18.77 kW/m2, which did not exceed the limit radiant heat flux, indicating that the fire impact on adjacent storage facilities was relatively small.

A study on the fire impact of Pentane outdoor storage tank (Pentane 옥외저장탱크의 화재 영향 검토에 대한 연구)

  • Eun-Ji Kim;Sung-Seek Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.18 no.3
    • /
    • pp.64-70
    • /
    • 2024
  • Fire prediction, response and assessment for outdoor storage tanks are essential to disaster management because they have significant human, social and environmental impacts. Therefore, in this study, the fire situation an outdoor storage tank was simulated and the effects of fire on the radiant heat flux were analyzed concerning tank height and fire occurrence time. tank height and fire occurrence time. For this purpose, fire scenarios and specifications of the outdoor storage tank were set, and a study was carried out considered height, fire occurrence time and the operating or non-operating of a water spray system in outdoor storage tanks containing large amounts of Pentane using FDS (Fire Dynamics Simulator). As a results, the radiant heat flux was reduced by more than 50% depending on whether the water spray system was m operating or not. When the water spray system was in operation, the maximum radiant heat flux was 13.75 kW/m2 at a tank height of 14 m, and when the water spray system was not 117 operation, the maximum radiant heat flux was 25.14 kW/m2 at the same tank height. Additionally, it was found that when the water spray system was in operation, the radiant heat flux was 50% lower than when the water spray system was not in operation.

A study on the development of drainage system for rapid drainage of thermal power plant outdoor coal storage during rainfall and characteristics of discharged water quality (강우시 화력발전소 옥외저탄장 신속한 배수를 위한 배수시스템 개발 및 배출 수질 특성에 관한 연구)

  • Lim, Chang-Min;Kwon, Hyun-Woo;Kim, Young-Min;Cho, Do-Young;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.189-190
    • /
    • 2022
  • Power plants that produce electricity through thermal power plants mainly store coal in outdoor storage yards. In particular, coal is directly exposed to rainwater during rainfall, including torrential rain. There is no separate drainage facility in the outdoor coal yard, and coal is simply stored on the ground. Accordingly, during rainfall, coal dust flows down by rainwater, and a large amount of rainwater that is not drained overflows the outdoor coal yard, overflowing the surrounding facilities and causing environmental pollution. Therefore, in this study, a drainage system was developed for the rapid drainage of an outdoor coal mine, and the quality of the water was evaluated when rainwater mixed with drainage characteristics and coal dust was discharged through the drainage system.

  • PDF

Study of Fire and Explosion Prevention of an Internal Floating Roof Tank (내부 부상형저장탱크(IFRT) 화재·폭발 예방대책에 관한 연구)

  • Koo, Chae-Chil;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.45-49
    • /
    • 2019
  • This study examined the safety of storage tanks by analyzing the causes of fire on outdoor storage tanks. The outdoor storage tank is a fixed device for the long-term storage of dangerous goods and consists of a tank body and accessories; the accessories consist of a vent system, breather valve, flame arrestor, etc. The flame arrestor is a necessary safety measure to prevent fire explosions on outdoor storage tanks. On the other hand, it has been suggested that the installation of a flame arrester is necessary to compare the domestic and international standards. In addition, the flame arrester should be installed in the existing outdoor storage tanks, to complement foreign standards because there are not enough domestic standards to verify the performance of the flame arrester.

Real-Time Building Load Prediction by the On-Line Weighted Recursive Least Square Method (실시간 가중 회기최소자승법을 사용한 익일 부하예측)

  • 한도영;이재무
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.609-615
    • /
    • 2000
  • The energy conservation is one of the most important issues in recent years. Especially, the energy conservation through improved control strategies is one of the most highly possible area to be implemented in the near future. The energy conservation of the ice storage system can be accomplished through the improved control strategies. A real time building load prediction algorithm was developed. The expected highest and the lowest outdoor temperature of the next day were used to estimate the next day outdoor temperature profile. The measured dry bulb temperature and the measured building load were used to estimate system parameters by using the on-line weighted recursive least square method. The estimated hourly outdoor temperatures and the estimated hourly system parameters were used to predict the next day hourly building loads. In order to see the effectiveness of the building load prediction algorithm, two different types of building models were selected and analysed. The simulation results show less than 1% in error for the prediction of the next day building loads. Therefore, this algorithm may successfully be used for the development of improved control algorithms of the ice storage system.

  • PDF

A Study on the Annual Storage Efficiency of Concentric Evacuated Tube Solar Energy Collector System (이중진공관형 태양열 집열기의 연간 집열효율에 관한 연구)

  • Kim, Ki-Chul;Paeng, Jin-Gi;Yoon, Young-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.50-55
    • /
    • 2008
  • The Storage efficiency of concentric evacuated tube solar collector is tested for one year from January 1st to December 31st under the real sun condition. The testing equipment is operated continuously for three days without cooling the storage tank. Daily storage efficiency is obtained from dividing stored energy in the storage tank by solar insolation on the solar collector for each day. Daily averaged temperature of the storage tank is lowest in January and highest in August. Monthly averaged storage efficiency is also lowest in November and highest in June. Therefore, it can be said that the storage temperature and the storage efficiency are roughly proportional to outdoor temperature. Furthermore, the daily storage efficiency is reversely proportional to $(T_s-T_a)/I_c$ where $T_s$ and $T_a$ are daily averaged storage temperature and outdoor temperature from sunrise to sunset, and $I_c$ is total insolation on the solar collector for a day.

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Analysis of Technical Pattern and Product Characteristics of Global Outdoor Sportswear (해외 아웃도어 스포츠웨어의 테크니컬 패턴과 제품 특성 분석)

  • Yoon, Mi Kyung;Roh, Eui Kyung
    • Journal of Fashion Business
    • /
    • v.25 no.3
    • /
    • pp.108-125
    • /
    • 2021
  • The purpose of this study is to analyze the technical pattern and product characteristics of outdoor sportswear marketed in Northern Europe and North America. Based on the results of this study, we wanted to provide practical data on the characteristics of products with high functionality and fashionability for developing outdoor sportswear. Therefore, in this study, technical pattern, textiles, details, sewing, compatibility with wearable devices, and certification of 33 marketed outdoor sportswear were analyzed. After analyzing various technical patterns, the bent arm pattern using two-piece panel and a raised arm pattern connecting the side seam with the inner seam of the sleeve appeared on the top. Additionally, the patterns of bent legs with darts in the knee, cutting the posterior, and inserting the gusset in the crotch were mainly seen in the bottoms. By analyzing product characteristics, ergonomic pattern design for easy activity and functional materials was used for climate adaptation in extreme outdoor wear. On the other hand, for outdoor wear meant for trekking or hiking, details, such as portability and easy storage, were considered. Eco-friendly materials were used while ensuring light weight and comfort. Furthermore, for convenience of life, safety, and health, wearable devices were integrated into the outdoor sportswear. Eco-friendly green certification of outdoor products was obtained for the labor environment and production process, and relevant information was provided to consumers.

A Study on Odor-Savor and Microbiological Changes of Mineral Water Depending on the Storage Period (생수의 저장기간에 따른 이·취미 및 미생물학적 변화에 관한 연구)

  • Lee, Woo-Sik;Seo, Kwang-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.441-449
    • /
    • 2014
  • As people seek a healthy, wealthy, and quality life more than before, interests in mineral water are picking up and the consumption continues to increase accordingly. In an experiment to examine changes in the water quality after mineral water on the market was kept indoor and outdoor for four weeks, there seemed to be no problem in external appearance. Water kept in an outdoor storage contained more odor-savor than water kept in an indoor storage. Odor was not detected in 90% of the sample, and savor not in 80% of it. As for the mechanism of odor-savor generation, the elution of chemical substances from a container may be taken into consideration. In general, odor and savor have turned out to be in close correlation to each other. The average number of bacteria in the sample mineral water was $200{\pm}10CFU/mL$, and such factors as area of storage and ozone post-treatment did not cause significant effects on the reproduction of common microbes. Hence, it is thought that strict regulations on a production process and reduction of the period of circulation will contribute to customers consumption rates.

Design of infrared image storage board for outdoor testing (야외시험용 적외선 영상 저장보드 설계)

  • Kim, Hong-Rak;Park, Jin-Ho;Kim, Kyoung-Il;Lee, Da-Been
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.161-166
    • /
    • 2021
  • When testing various images outdoors with an infrared imaging system, it is necessary to save the tested images for comparison. In addition, after the test, it should be possible to easily connect to the PC and download the stored data. With the recent development of the memory system, it is possible to design an infrared image storage board for an outdoor test by using the eMMC memory that can be easily used in the form of an on board. In this paper, we describe the design of a portable image storage board that can easily store and download infrared images, and describe the GUI program that can connect to a PC and download the stored images.