• Title/Summary/Keyword: Outdoor experiments

Search Result 266, Processing Time 0.026 seconds

Bright Surround Luminance and Perceived Image Contrast

  • Kim, A-Ri;Kim, Hong-Suk;Park, Seung-Ok;Baek, Ye-Seul;Kim, Youn-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.745-748
    • /
    • 2008
  • The theory of Bartleson and Breneman that the perceived image contrast changes with surround luminance (the lighter surround provides higher contrast) was tested an over bright condition($8500d/m^2$). Contrarily to the Bartleson and Breneman's results, we observed the fact that perceived constrast was decreased when surround huminance increased from dark to over bright through two sets of psychophysical experiments based upon both uniform gray patches and complex color images.

  • PDF

Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation (공동주택 지하주차장의 자연채광 실태 및 채광성능 평가)

  • Chung, Yu-Gun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

Characteristics of Material Damage Caused by Acid Deposition in East Asia

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.445-454
    • /
    • 2002
  • Material exposure experiments were performed to evaluate the relationship between air pollution and material corrosion rates based on collaboration with researchers in China, Japan, and Korea. Qualitative and quantitative atmospheric corrosion was estimated from damage caused to bronze, copper, steel, marble, cedar, cypress, and lacquer plates exposed to outdoor and indoor conditions in certain East Asian cities. The effects of atmospheric and meteorological factors on the damage to the copper plates and marble pieces were estimated using a regression analysis. The results indicated that sulfur dioxide produced the most destruction of the materials, especially in South Korea and China. In Japan, the copper plates were damaged as a result of natural conditions and sea salt. Copper was also found to be damaged by the surface deposition of sulfur and chlorine. Meanwhile, marble was substantially degraded by gaseous sulfur dioxide, yet sulfate ions in rain had no effect. Accordingly, the analysis of air pollution from the perspective of material damage was determined to be very useful in evaluating and substantiating the intensity of air pollution in East Asia.

An Experimental Study on Magnet for Electro-Magnetic Maglev Vehicle(V) (상전도 흡인식 자기부상차량용 전자석의 실험적 연구(V))

  • Kim, Bong-Seop;Chung, Hyun-Kap;Ha, Kyoung-Duck;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.28-31
    • /
    • 1997
  • Experiments and design efforts have been made to improve performance of the levitation magnet. One pole of the pair-magnet is manufactured as a solid core without stagger and its test result gives a 5 % increment of levitation force. One effort is to make molding coil to protect it from vibration and precifitation due to outdoor usage. In addition, a permeant magnet embedded type has been designed and analyzed by using FEM program.

  • PDF

Numerical Simulation of the Wind Flow Over a Triangular Prism with a Porous Windbreak (다공성 방풍벽이 설치된 삼각프리즘 주위 유동장의 수치모사)

  • 김현구;임희창;이정묵
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.223-233
    • /
    • 1999
  • The wind-flow characteristics over a two-dimensional triangular prism with a porous windbreak are numerically investigated. The geometry is a simplified model of large outdoor stack with a frontal wall-type windbreak which is used to prevent particle dispersion by reducing wind speed over stak surface. In the present numerical model, the RNG k-$\varepsilon$ model, the orthogonal grid system and the QUICK scheme are employed for the successful simulation of separated flow. The predicted results are compared and validated with the associated wind-tunnel experiments. In addition, the trajectories of dispersed particles and their sedimentation characteristics are quantitatively investingated using a Lagrangian turbulent-dispersion model.

  • PDF

Real Time W-band FMCW Distance Measuring Devices Using TMS320C6701 DSP (TMS320C6701 DSP를 이용한 실시간 W-대역 FMCW 거리측정장치)

  • Lee, Chang-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2006
  • This paper presents a real time distance measuring device using a W-band linear frequency modulated continuous wave(FMCW) radar and TMS320C6701 digital signal processor(DSP). We used FFT operation for measuring distance with the beat signals and the results of FFT could be converted to distance with ease. We presented how to implement a real time miniaturized hardware system including network protocols using a single DSP core. Also how to control the modulation signal of FMCW system to compensate the VCO nonlinearity using the Time Gating control of DSP is presented. We have shown that the proposed system has good performances for measuring distance in real time via outdoor environment experiments.

A New Evaluation Method of Reflective LCDs

  • Byun, Jin-Seob;Nam, Seok-Hyun;Park, Gi-Chang;Ju, Jin-Ho;Kim, Jang-Sub;Kang, Sung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.852-855
    • /
    • 2002
  • Quality of the reflective LCD as a display is strongly influenced by the environment where the display is evaluated. Up to now, several methods for the evaluation of the reflective LCDs have been proposed. We have developed a new method in which the optical characteristics of the reflective LCDs from the spot light and the diffuse light can be obtained at the same time. The results obtained in our experiments by using the new method showed a good agreement with those evaluated at office and outdoor environments.

  • PDF

Formation-Keeping of Multiple Robots using Chained-Poles (연결극점을 이용한 다중로봇의 대형유지)

  • Kwak, Jae-Hyuk;Kang, Hyun-Deok;Kim, Chang-Hwan
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.218-224
    • /
    • 2009
  • We propose a formation-keeping and changing methods for outdoor multiple mobile robots in chained form. Our proposed method is designed to maintain the follower to its desired distance and orientation with respect to the pole using the concept of virtual force such as potential field. The client robots use a behavior-based control to perform kinematic control to keep formation under the centralized system in our software framework. The relationship of each poles that is expressed by set of distance and angle is the description of the formation type and the type converting is performed using this set. In addition, we also examine the stability and capability in the simulation and experiments with real robots.

  • PDF

Development of Health, Safety and Environmental Risks from the Operation of CdTe and CIS Thin-Film Modules (CdTe와 CIS 박막 모듈의 운전시 건강, 안전 및 환경위험에 대한 고찰)

  • Lee, Sung-Rae
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.21-26
    • /
    • 2008
  • Solar cells are renewable energy source which is not only environmentally friendly but also economically viable. For that matter, thin film materials are in observed with great in terest by a number of sources throughout the nations. Among these, CdTe (Cadium telluride) and CIS (copper indium diselenide) are the latest commercial products that are gathering attention in the solar cells markets. However there are some downsides to this newly invention. Since the materials are embedded, in the occasion of damage, certain amount of module residue can be released to water or soil. This paper outlines the results of our outdoor leaching experiments on photovoltaic (PV) samples broken into small fragments and been observed for 1 year.