• 제목/요약/키워드: Outdoor Thermal Condition

검색결과 73건 처리시간 0.029초

일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가 (A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier)

  • 황광일;도근영;조효제;우상우;신동걸;임성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

노인복지시설의 하절기 실내 온열환경과 노인의 주관적 반응평가에 관한 연구 -대구광역시 소재 노인복지시설을 중심으로 (A Study on the Estimate of Thermal Environment and the Subjective Responses of the Aged during Summer in the Welfare Facilities -Focused on the Welfare Facilities for the Aged in Taegu-)

  • 이형우;홍원화
    • 한국주거학회논문집
    • /
    • 제13권2호
    • /
    • pp.23-29
    • /
    • 2002
  • The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.

사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가 (Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer)

  • 박수진;정선영;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

아파트의 겨울철 실내온열환경 실태와 생활요인 분석 (Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter)

  • 최윤정;정연홍
    • 한국주거학회논문집
    • /
    • 제19권4호
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.

석탄의 열적 특성과 석탄 내부의 승온 특성과의 상관관계 연구 (Study on the Correlation between Thermal Characteristics and Heat Accumulation in the Coal Pile)

  • 이현동;김재관
    • 한국연소학회지
    • /
    • 제15권4호
    • /
    • pp.58-64
    • /
    • 2010
  • Spontaneous ignition tests of five different coals with non-iso-thermal and iso-thermal test method based on the standard test procedure of NF T20-036 were carried. These five coals included the 2 low rank coals and 3 bituminous coals. Test results showed that the ignition temperatures of all coals at the iso-thermal conditions were higher than that of non-isothermal condition, and those of low rank SM and BR coal in both nonisothermal and isothermal conditions were lower than bituminous AN and CN coals. The chemical species of coals such as oxygen and hematite also plays an important role in enhancing the ignition rate that the ignition temperature of SM coal was lowered. The heat accumulation tendency of five coals inside outdoor stack pile was monitored with emphasis on the change in the temperature of the coal depth in stack pile. In case of low rank BR coal, its temperature inside coal stack pile due to the rate of high heat accumulation and oxidation was $59^{\circ}C$ compared to $51^{\circ}C$ for other SW bituminous coal. And the heat accumulation rate inside coal stack piles was increased with increased the Cp value which it was defined as the specific heat of coal at constant pressure, whereas other factors such as thermal diffusivity and conductivity of coal relatively had less effect on heat accumulation.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • 이정헌;정다솔;남영석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF

서열환경하에서의 전투복착용이 체온조절에 미치는 영향 (The Influence of Wearing Army Combat Uniform on the Thermal Responses in Heat Environment)

  • 김태규;조호현
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.167-174
    • /
    • 2014
  • The physical properties of textile materials and thermal physiological responses of the human subjects were evaluated with 4 different types of the army combat uniforms including US, German, Korean and general uniforms for this study. 8 male adults were used as the human subjects and the tests were done in the environmental chamber that was $25{\pm}0.1^{\circ}C$ of temperature, $65{\pm}5%$ of relative humidity and below 0.3 m/sec of air velocity. The test protocol consisted the rest period for 20 min., the exercise period for 20 min., the rest period for 20 min., the exercise period under wind condition for 20 min., and the recovery period for 20 min. The human subjects walked with 4.5 km/hr for 10 min., ran 7.5 km/hr for 10 min. during the first exercise period and walked and ran with the same speeds under 3.5 m/sec of the air velocity that simulated outdoor condition during the second exercise period. The test results of the study were as follows; The wind condition affected the skin and microclimate temperature of the human subjects lower compared to without wind condition, but had insignificant effect on the humidity control. The low air permeability of Korean uniform caused blocking the elimination of the humidity from the body and the regulation of body temperature. However, Korean uniforms could be the excellent one with the designs considering the ventilation of the uniforms and the textile fabrics with better air permeability.

주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구 (An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House)

  • 이충국;조성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

사용 환경조건에 따른 Epoxy/Glass Fiber 복합재료의 표면특성 (Surface properties of epoxy/glass Eber composites by environmental conditions)

  • 임경범;이백수;황명환;김윤선;유도현;이덕출
    • 한국진공학회지
    • /
    • 제9권3호
    • /
    • pp.279-284
    • /
    • 2000
  • 본 연구는 옥외용 epoxy/glass fiber의 열화과정을 분석하기 위하여 FRP 적층판을 고온과 수에 노출시켰다. 열화과정은 접촉각, 표면전위감쇠, 표면저항률의 비교에 의해 평가하였다. 젖음성의 변화는 열처리 시료에서 $200^{\circ}C$까지 접촉각이 증가하였지만 수분처리 시료는 감소하였다. 표면전위감쇠 특성은 수분처리 시료에서는 감소하지만, 열처리 시료는 미 처리와 비교해서 증가하였다. 또한, 표면저항률은 접촉각의 변화와 같은 경향을 보이고 있다.

  • PDF