• Title/Summary/Keyword: Outdoor Noise

Search Result 198, Processing Time 0.027 seconds

Vibration Reduction Using Wire Mounting - Test Results (Wire Mounting을 이용한 진동저감에 대한 실험 연구)

  • 최상현;박윤식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.403-408
    • /
    • 2001
  • Structure-borne noise and vibration is one of the main complaints of home appliances such as refrigerators, washing machines, air conditioners, etc. There have been many efforts to reduce the emitting noise and vibration. Mostly the efforts have been concentrated to optimize the mounts shape and its material properties realizing that the vibration power is mainly transmitted to the structure via mounts. It is known that softer mounts have the better vibration isolation effect. But mounts have another important function in addition to the vibration isolation. That is to support the motor and compressor safely. Thus mounts should be stiff enough to resist the supporting items. But the two properties, stiff and soft, are contradict each other. So the designer should compromise the two complicity properties properly in between. Noticing that, motors and compressors themselves are very quite until they are connected to the base structure via mounts, wire connecting idea was proposed in this work. Instead of using conventional mounts, as shown in Fig 4, compressor was mounted using six wires as shown in Fig 5. Since wire is very flexible in bending but stiff in tension, we can realize the ideal mount design requirements, stiff enough to support and soft enough to isolate vibration power. The suggesting idea was tested with an air conditioner outdoor unit.

  • PDF

Indoor and Outdoor Noise Characteristics and Impact on the Hospital Building by Olympic Expressway (올림픽도로에 인접한 병원건물에서 내외부 소음특성과 그 영향에 관한 연구)

  • 조창근;손장열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.37-44
    • /
    • 1993
  • 본 연구는 올림픽 도로에 인접한 병원건물의 내외부에서 교통 소음을 동시에 측정하여 대상 병원건물에서의 교통소음 특성과 그 소음이 병원건물에 미치는 영향을 파악하고 소음 방지 대책의수립에 필요한 기초자료를 제시한다. 본 연구에서는 올림픽도로에서 발생하는 교통소음의 변동 및 분포특성, 주파수 특성, 도로교통소음으로 인한 건물실내의 소음도를 파악하였으며, 실내에서의 소음도는 ISO의 권장치를 초과하는 것으로 나타나 소음저감 대책이 필요한 것을 알 수 있었다. 본 연구는 도로주변에서의 특정건물에 대한 연구이나, 그외 건물의 소음방지대책에도 참고가 될 수 있을 것으로 사료된다.

  • PDF

Development of aerodynamic noise measurement method for high-speed trains (고속철도차량의 공력소음 측정 시험법 개발)

  • Minseung Jung;Jaehwan Kim;Hyung-Suk Jang;Jonghwan Kim;Cheolung Cheong;Kwongi Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.131-137
    • /
    • 2024
  • Aerodynamic noise generated by the surrounding flow of a train traveling at high speed affects both outdoor and indoor noise. This study's goal is to develop a test method to measure and quantitatively evaluate aerodynamic noise through pressure perturbation data on the train surface. To accurately evaluate aerodynamic noise, it is important to separate and evaluate the compressive and incompressible pressure fluctuations mixed in the acquired surface pressure fluctuation data. This is because the noise transmission characteristics of the two pressure fluctuations are different. First, the installation length and interval of the microphone were determined to acquire surface pressure fluctuation data, and wavenumber-frequency analysis was performed to separate incompressible pressure fluctuation and compressible pressure fluctuation to obtain a sound pressure level spectrum. Finally, as a result of comparing the test results measured in the train head and trail, It was confirmed that the pressure fluctuation on the train head surface was greater than that on the tail.

An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window (현장에서의 창의 차음성능 측정방법에 관한 실험적 연구)

  • Lee, Ok-Kyun;Park, Hyeon-Ku;Choi, Hyung-Wook;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

A Scalar Adaptive Filter Considering Acceleration for Navigation of UAV (무인기의 항법을 위한 가속도를 고려한 적응 스칼라 필터)

  • Lim, Jun-Kyu;Park, Chan-Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • This paper presents a novel scalar adaptive filter, which is reformulated by additional acceleration term. The filter continuously estimates three different kinds of covariance such as the measurement noise covariance, the velocity error covariance and the acceleration error covariance. For estimating three covariances, we use the innovation method for the measurement noise covariance and the least square method for other covariances. In order to verify the proposed filter performance compared with the conventional scalar adaptive filter, we make indoor experimental environment similar to outdoor test using the ultrasonic sensors instead of GPS. Experimental results show that the proposed filter has better position accuracy than the traditional scalar adaptive filter.

Unsteady Flow Characteristics of an Axial Flow Fan Installed in the Outdoor Unit of Air Conditioner (에어콘 실외기용 축류송풍기의 비정상 유동장 특성 연구)

  • Jang, Choon-Man
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.223-230
    • /
    • 2005
  • The unsteady nature of vortex structures has been investigated by a large eddy simulation (LES) in an axial flow fan with a shroud covering only the rear region of its rotor tip. The simulation shows that the tip vortex plays a major role in the structure and unsteady behavior of the vortical flow in the fan. The movements of the vortex structures induce high-pressure fluctuations on the rotor blade and in the blade passage. Frequency characteristics of the fluctuating pressure on the rotor blade are analyzed using wavelet transform. The dominant frequency of the real-time pressure selected at the high pressure fluctuation region corresponds well to that of the fluctuating rotor torque and the experimental result of fan noise. It is mainly generated due to the unsteady behavior of the vortical flow, such as the tip vortex and the leading edge separation vortex.

  • PDF

Prediction of the Specific flow resistivity of the Ground Surface by Acoustical Method (음향학적 방법에 의한 지표면의 유동 비저항 예측)

  • 황철호;정성수;은희준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.237-243
    • /
    • 1997
  • Most outdoor sounds go from sources relatively near the ground to receivers near the ground. When either source or receiver are near the ground, interference can occur between the direct sound and that reflected at the ground which travels a slightly longer path. The sound pressure at the receiver is very different depending on the state of ground surface i.e. ground impedance. Ground impedances could be characterized by the value of a single parameter, namely the flow resistivity of the ground surface. This study suggests the measurement method of the flow resistivity using two microphones and predicts the flow resistivities of various ground surfaces.

  • PDF

Design and Performance Analysis of Visible -Light Wireless Communication System using LED

  • Choi, Jae Myoeng
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.8 no.2
    • /
    • pp.147-157
    • /
    • 2018
  • In this study, we analyzed an outdoor visible light communication system and implemented it through a simulation. We designed a Reed-Solomon encoder, a variable interleaver structure, and set it to the Institute of Electrical and Electronics Engineers (IEEE) 802.15.7 PHY I specification mode. We also analyzed the performance of an additive white gaussian noise (AWGN) channel environment using a root-raised-cosine (RRC) filter, implemented a MATLAB simulation and analyzed its performance. The results showed a requirement for an additional signal-to-noise ratio (SNR) of approximately 1.5 dB in a 3-ray multipath visible light channel environment than in an AWGN environment.

A Study on the Soundproofing Plate Techniques for Noise Reduction of Power Transformers (전력용 변압기 소음저감을 위한 차음판 기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chon;Kim, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.47-55
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an enclosure to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. To shut out sound emitted from transformers, we developed a soundproof technology that wall up reinforcing bar by steel sheet. For the practical application of it, we analyzed the vibration characteristics of a transformer tank and reduction of noise according to soundproof plate. As a result, it is confirmed that the technology can reduce 11 [dB] of transformer noise.

A study on the effect on indoor air quality by ventilation system operation in buses (고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화)

  • An, Sun-Min;Lee, Jung-Sub;Shim, In-Keun;Kim, Ho-Hyun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.