• 제목/요약/키워드: Outdoor Insulation

검색결과 138건 처리시간 0.028초

투명방음판의 품질기준 설정에 관한 연구(2) - 음향 특성 및 내후성 평가 (Study on Quality Criteria for Transparent Soundproof Panels(2) - Sound Insulation Characteristics and Evaluation of Weatherability)

  • 장태순;김철환;황철호
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1099-1105
    • /
    • 2012
  • Transparent noise barrier panels have the advantages of transmitting light to nearby residents and allowing drivers to orientate themselves by providing views of the surrounding area. To develop guidelines on quality criteria for transparent soundproof panels, their sound transmission loss and weatherability were experimentally investigated. In Korea, the sound transmission loss of noise barrier panels should be more than 25 dB at 500 Hz and 30 dB at 1000 Hz. The transmission loss tests of transparent panels were performed in accordance with KS F 2808. Typically, plastic materials suffer from color changes when exposed to ultraviolet(UV) light over extended periods. Therefore, weathering of plastics is one of the most important properties for outdoor applications. Protection against UV radiation and weathering is usually accomplished by using UV stabilizer additives or coatings. Transparent materials for soundproof panels were examined through accelerated weathering tests and their weathering resistances were evaluated from changes in yellowness index.

옥상녹화 조성지역의 현황평가 및 이용객 만족도 연구 (The Evaluation of Present Condition and Visitors Satisfaction of Rooftop Greening)

  • 이동근;윤소원;오승환;장성완
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.45-58
    • /
    • 2005
  • The objective of this study is to the integrated evaluation of the present condition and satisfaction of visitors of rooftop greening area using quantitative and qualitative method. The thirteen green roofs were selected to investigate environmental variables as like building structure, soil, water, atmosphere and climate environment and questionnaire survey for investigate the satisfaction of visitors was conducted. The results of this study are as follows : remove of the hazardous inflow of species, install rain water recycling facility, install outdoor unit of air condition where not to affect plants in green roof, install safety facilities in the case of making resting place, plant variable vegetation and so on. The result of questionnaire survey are that visitors want to make more comfortable resting space. The more bigger the resting space and privacy, the more satisfaction of visitor became high. In conclusion, green roofs implementation should be considered reduction of temperature and delay of runoff, insulation effect and ecological restoration as well as rooftop greening is focused on the development of resting space nowadays.

지역난방 공동주택의 건축물 에너지절약 설계기준 강화에 따른 난방에너지 사용량 분석 (Analysis of Heating Energy Consumption of District Heated Apartment with respect to Reinforcement of Building Energy-saving Design Criteria)

  • 이성우;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.16-22
    • /
    • 2011
  • Since 1970s, energy-saving design criteria of buildings has been improved through numerous revisions. The purpose of this research is to show how energy saving design criteria affects heating energy consumption of apartments using district heating. Heating energy consumption has been measured in 4 apartments located in Gyeonggi province, Korea from Nov. 1,2007 through Oct. 31, 2008. Collected data was regressed to linear correlations. Heating energy consumptions were calculated for past, present and future energy-saving design criteria, which are outdoor temperature, ventilation and insulation. The results show that present design criteria has reduced heating energy consumption by 15%, and the future criteria will reduce the energy consumption by 42% compared to the criteria before 2001.

트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가 (Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test)

  • 조한구;안명상;한세원;허종철;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Salt fog 시험법에 의한 실리콘 고무의 표면 열화 및 발수성 회복 특성 (Surface aging and hydrophobicity recovery of silicone rubber by salt fog method)

  • 김정호;서광석;문중섭;송우창;이재형;박용관;양계준;유영식
    • 한국전기전자재료학회논문지
    • /
    • 제13권7호
    • /
    • pp.636-641
    • /
    • 2000
  • The purpose of this study is assessing the characteristics of surface aging and recovery of hydrophobicity for silicone rubber which takes a great interest as outdoor insulation recently subjected to the combined stressed of salt fog and AC power. The methods for assessing are contact angle ATR-FRIR, AFM and XRD. In addition salt fog method is adopted as the artificial contamination experiment and AC power is applied 24 hour on and 24 hour off repeatedly for 5 cycles. The results suggest that degraded surface was more rough than virgin but was restored water repellency through the off cycle. It was due to not only the formation of fractal surface but also maintenance of hydrophobic surface by diffusion of low molecular oil. Although surface recovers initial hydropohbicity there are possibilities of decreasing electrical performance due to irreversable changes such as depolymerization of surface and loss of filler particles. This fact is confirmed by surface conductivity measurement showing that the degradation is significant and the recovery of hydrophobicity is imperfect as the energized cycle increases.

  • PDF

온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용 (Development and application of on-line lightning information service)

  • 곽주식;우정욱;강연욱;구교선;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF

냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode)

  • 정현준;주영주;강훈;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

광기능성 창호시스템의 동절기 채광특성에 관한 목업연구 (Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls)

  • 김곤
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

하계 항만열환경정보 제공을 위한 열환경 평가 및 예보시스템 구축 (Heat Stress Assessment and the Establishment of a Forecast System to Provide Thermophysiological Indices for Harbor Workers in Summer)

  • 황미경;윤진아;김현수;김영준;임연주;이영미;김영남;윤의경;김유근
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.92-101
    • /
    • 2016
  • Objectives: Outdoor workers are exposed to thermally stressful work environments. In this study, heat stress indices for harbor workers in summer were calculated to evaluate thermal comfort based on a human heat balance model. These indices are Physiological Subjective Temperature (PST), Dehydration Risk (DhR), and Overheating Risk (OhR) according to respective stage of cargo work in a harbor. In addition, we constructed a forecast system to provide heat stress information. Methods: Thermophysiological indices in this study were calculated using the MENEX model (i.e. the human heat balance model), which used as inputs the meteorological parameters, clothing insulation, and metabolic rate for each stage of cargo work in the harbor of Masan over the course of seven days, including a four-day heat wave. The forecast heat stress information constructed for Masan harbor was based on meteorological data supported by the Dong-Nae Forecast from the KMA (Korea Metrological Administration) and other input parameters. Results: According to higher metabolic rate, thermophysiological indices showed a critical level. In particular, PST was evaluated as reaching the 'Very hot' or 'Hot' level during all seven days, despite the heat occurring over only four. It is important in a regard to consider the work environment conditions (i.e. labor intensity and clothing in harbor). On a webpage, the forecast thermophysiological indices show as infographics to be easily understand. This webpage is comprised of indices for both current conditions and the forecast, with brief guidance. Conclusion: Thermophysiological indices show the risk level to health during a heat wave period. Heat stress information could help to protect the health of harbor workers. Further, this study could extend the applicability of these indices to a variety of outdoor workers in consideration of work environments.

기능성 등산복의 착용실태 조사 (Research on the Wearing Condition of Functional Mountaineering Garments)

  • 이아람;정정림;김희은
    • 한국의류학회지
    • /
    • 제33권12호
    • /
    • pp.1935-1940
    • /
    • 2009
  • 본 연구는 기능성 등산복의 착용실태를 조사하여 등산복의 개발과 차별화에 기여하고자 하였다. 등산을 즐기는 107명의 응답자들이 본 설문조사에 응해주었고 문항은 개인정보, 구매습관, 등산복 선택시 가장 중요하게 여기는 기능, 본인이 소유한 등산복의 기능에 대한 만족도, 자유기술의 5개 항목으로 이루어져 있었다. 응답자들은 기능성 등산복을 선택할 때에 가장 중요하게 여기는 특성으로 흡습속건성, 보온성, 방수방풍성, 스트레치성 기능을 열거하였다. 이 기능들은 한 겹의 의복으로 착용하기보다는 여러 겹 겹쳐입을 경우 특히 그 효과가 증대한다 할 수 있다. 그리고 스트레치성의 경우 하체의 움직임이 많은 등산 활동 시 하의에 특히 필요한 기능이라 응답하였다. 그리고 응답자들은 기능성 등산복의 가격이 너무 비싸다고 응답하였으며 세탁이 불편하다고 답하였다. 이러한 설문결과로 보아 기능성 등산복의 개발 시 소비자들이 중요하게 여기는 기능을 고려해야 할 뿐만 아니라, 세탁성이나 가격과 같은 소비자들이 개선을 원하는 요소들에 대한 고려도 필요할 것이다.