• 제목/요약/키워드: Out of phase mode

검색결과 210건 처리시간 0.031초

모드 순서 전환된 2자유도계 압전 진동 에너지 수확 장치의 수학적 모델 (Mathematical Model for a Mode-sequence Reversed Two-degrees-of-freedom Piezoelectric Vibration Energy Harvester)

  • 이소원;김윤영;김재은
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.546-552
    • /
    • 2013
  • A cantilevered piezoelectric energy harvester(PEH) and an auxiliary mass-spring unit can be integrated into a novel two-degrees-of-freedom PEH where its lowest eigenmode is not an in-phase modes but an out-of-phase mode. This typical behavior was shown to enhance output power considerably compared with its stand-alone counterpart. The objective of this study is to newly develop a continuum-based mathematical model suitable for efficient analysis of the mode-sequence reversed PEH. Once such a mathematical model is available, various physical behaviors can be analytically investigated for better designs. After a new mathematical model is developed, its validity is checked by using ANSYS results, in terms of resonant frequency, open-circuit voltage, and output power with a specified external resistance.

액체연료 의 분사연소시 분사조건 이 화염 과 액적군 의 성질 에 미치는 영향 (The Effects of Spray Parameters on the Flame and Spray Characteristics for Liquid Fuel Spray Flame)

  • 김호영
    • 대한기계학회논문집
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 1984
  • 본 연구는 Kim과 Chiu가 사용한 연속체 관점에서 유도된 액체-기체상의 2상유 동모델(Two Phase Flow:TPF)을 이용하여 초기 집단연소수(group combustion number)의 크기, 즉 액적들의 초기 분포상태에 따른 연소상태를 예측 분류한다. 또한 이때 예 측된 대표적인 연소상태에서 형성되는 화염의 성질을 비교 검토한다.

단상 UPS 시스템의 모드 절환 시퀀스 및 제어 (Mode Transfer Sequence and Control of Single-phase UPS System)

  • 이상석;이순령;최봉연;이정효;원충연
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.108-115
    • /
    • 2014
  • Recently, Uninterruptible power supply(UPS) is spotlighted from concern about black out, due to reserve power problem caused by increased power consumption. When fault occurs on the grid, UPS system supplies power to loads instead of the grid. Also, it is an advantage of possible operation as Energy storage system(ESS). Bi-directional power control of AC/DC Pulse width modulation(PWM) converter is essential for grid-connected UPS system. And, mode transfer control has to be performed considering phase and dynamic characteristic under grid condition. In this paper, control of mode transfer and bi-directional power control of AC/DC PWM converter is proposed for UPS system. Also, it is verified by simulation and experimental results.

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

Estimation of a mixed-mode cohesive law for an interface crack between dissimilar materials

  • Song, Sung-Il;Kim, Kwang-Soo;Kim, Hyun-Gyu
    • Multiscale and Multiphysics Mechanics
    • /
    • 제1권1호
    • /
    • pp.35-51
    • /
    • 2016
  • In this paper, a mixed-mode cohesive law for an interface crack between epoxy and TR (transparent thermoplastic) resin is inversely estimated by the field projection method using numerical solutions and experimentally measured displacements. Displacements in a region far away from the crack tip are measured by digital image correlation technique. An inverse analysis, the field projection method formulated from the interaction J- and M-integrals with numerical auxiliary fields, is carried out to estimate a mixed-mode cohesive law for an interface crack between dissimilar materials. In the present approach, nonlinear deformations and damage near the crack tip are converted into the relationships of tractions and separations on crack surfaces behind the crack tip. The phase angle of mixed-mode singularities of the interface crack is also obtained from measured displacements in this study.

슬라이딩 모우드(Sliding Mode) 제어(制御)에 의한 AC Servo motor의 위치제어(位値制御)에 관한 연구(硏究) (Ac Servo motor position control using Sliding mode control)

  • 홍창희;이형기;박양수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.53-55
    • /
    • 1988
  • The application of Sliding Mode Control for inproving the dynamic response of a Multi-Phase-Bipolar (MPB) Brushless DC motor based position Brushless DC motor system is presented. Sliding Mode Control gives fast dynamic response with no overshoot and zero steady state error. It has the important feature of bins highly robust. A design procedure is outlined for the Sliding Mode Controller for a MPB Brushless DC motor. Digital computer simulation of the overall position control system is carried out using a time domain model in the d-q reference frame.

  • PDF

Bound Mode의 외중력파에 의한 항내 이상파 생성가능성에 대하여 (On the Feasibility of Freak Waves Formation within the Harbor Due to the Presence of Infra-Gravity Waves of Bound Mode Underlying the Ever-Present Swells)

  • 조용준;배정현
    • 한국해안·해양공학회논문집
    • /
    • 제31권1호
    • /
    • pp.17-27
    • /
    • 2019
  • Bound mode의 외중력파와 이로 인한 보강간섭이 이상파 생성 기작이라는 가설을 확인하기 위해 OpenFoam 기반 Tool box인 ihFoam과 Bi-spectrum에 기초한 수치모의를 수행하였다. 수치모의는 건설 과정에서 이상파가 관측된 삼척 LNG 생산기지 전용부두를 대상으로 수행되었으며, Bound mode의 외중력파는 Bi-spectrum에 기반하여 출현빈도가 높은 주기가 7초인 국지 풍성파와 11.4초인 너울의 difference interaction으로 생성하였다. 또한 비교를 위해 비선형 Cnoidal wave, linear wave를 대상으로 한 수치모의도 병행하여 수행하였다. 모의결과 N 계열 bound mode의 외중력파에 의해 삼척 LNG 생산기지 전용부두를 따라 진행되는 연파가 생성되며, 이상파는 전술한 연파와 남측 도류제로부터의 반사파가 더해져 출현하는 것으로 모의되었다.

삼상 자속구속형 한류기의 동작모드분석 (The Analysis of Operation Mode of Three-Phase Flux-Lock Type Superconducting Fault Currents Limiter)

  • 황종선;최효상;박형민;조용선;이나영;남긍현;한태희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.46-48
    • /
    • 2006
  • We investigated the analysis of operation mode of three-phase flux-lake type superconducting fault current limiter(SFCL). The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero and the SFCL has negligible influence on the power system, However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes elements of all phase-quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase.

  • PDF

Quantitative Analysis and Comparisons between In-Phase Control and Energy-Optimized Control for Series Power Quality Controllers

  • Xinming, Hunag;Jinjun, Liu;Hui, Zhang
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.553-566
    • /
    • 2009
  • In-phase control and energy-optimized control are the two major control strategies proposed for series power quality controllers (SPQC). However quantitative analysis and comparison between these two control strategies is quite limited in previous publications. In this paper, an extensive quantitative analysis is carried out on these two control strategies through phasor diagram approach, and a detailed quantitative comparison is conducted accordingly. The load current is used as the reference phasor, and this leads to a simpler and clearer phasor diagram for the quantitative relationship. Subsequently detailed analysis of SPQC using in-phase control and energy-optimized control are provided respectively, under different modes both for under voltage/voltage sag and for over voltage/voltage swell. The closed form analytic expressions and the curves describing SPQC compensation characteristics are obtained. The detailed system power flow is figured out for each mode, and the detailed quantitative comparison between the two control strategies is then carried out. The comparison covers several aspects of SPQC, such as required compensating voltage magnitude, required capacity of energy storage component, and maximal ride-through time. In the end, computer simulation and prototype experimental results are shown to verify the validity of all the analysis and the result of the comparison.

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF