• Title/Summary/Keyword: Out of distribution detection

Search Result 204, Processing Time 0.036 seconds

Analysis and Design of FRT Detection System Using PMU (PMU를 사용한 FRT 검출시스템 설계 및 분석)

  • Kwon, Dae-Yun;Moon, Chae-Joo;Jeong, Moon-Seon;Yoo, Do-Kyeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.643-652
    • /
    • 2021
  • Accidents or faults in the transmission and distribution system are never completely avoidable, and short-circuit and earth faults are occurs despite the efforts of the TSO and DSO. Recently, the connection to the transmission and distribution system of large-capacity new and renewable distributed power has increased rapidly and has various effects on the operation of the system. In order to minimize this, connection standards such as FRT (Fault-Ride-Through) have been established to provide wind turbines or solar inverters. In the event of a major faults of the power system, the operation support shall be provided so that the operator can stably operate the system by smoothly performing connection maintenance or rapid system separation. In this paper, in order to appropriately determine whether the FRT condition, which is the grid connection criterion for a representative DERs, is sufficient, a detection system using a PMU (Phasor Measurement Unit) that measures a synchro-phasors was designed and deployment and a system accident due to a generator step-out to analyze and evaluate the proposed system based on the case.

Distribution of Vibrio vulnificus the Coast of South Korea (한국연안의 Vibrio vulnificus의 분포에 관한 연구)

  • KIM Young-Man;SHIN Il-Shik;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.591-600
    • /
    • 1987
  • To evaluate the detection rate and the density of Vibrio vulnificus by the sample, sampling area and date, 240 sea water samples and marine invertebrates were collected from coastal area of Korea including Pohang, Chungmu, Yeosu, Kunsan, Sihwa and Pusan from March to October, 1986. Eighty two strains oft of 1087 strains isolated from the submitted samples were identified as V. vulnificus. Forty seven of total 240 samples were positive in V. vulnificus which were constituted by 31 out of 138 sea water samples and 16 out of 102 marine invertebrates. Detection rate of V. vulnificus among the invertebrates was high in the crab, Portunus trituberculatus and the ark shell, Anadara broughtonii samples. The samples collected at Kunsan area showed the highest in detection rate of the bacterium as $67\%$ during the study period and the density of V. vulnificus was high in the sea water which was low in salinity.

  • PDF

Analysis of a Simulated Optical GSO Survey Observation for the Effective Maintenance of the Catalogued Satellites and the Orbit Determination Strategy

  • Choi, Jin;Jo, Jung Hyun;Yim, Hong-Suh;Choi, Young-Jun;Son, Ju-Young;Park, Sun-youp;Bae, Young-Ho;Roh, Dong-Goo;Cho, Sungki
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.237-245
    • /
    • 2015
  • A strategy is needed for a regional survey of geosynchronous orbits (GSOs) to monitor known space objects and detect uncataloged space objects. On the basis of the Inter-Agency Debris Committee's recommendation regarding the protected region of geosynchronous Earth orbit (GEO), target satellites with perigee and apogee of $GEO{\pm}200km$ and various inclinations are selected for analysis. The status of the GSO region was analyzed using the satellite distribution based on the orbital characteristics in publicly available two-line element data. Natural perturbation effects cause inactive satellites to drift to two stable longitudinal points. Active satellites usually maintain the designed positions as a result of regular or irregular maneuver operations against their natural drift. To analyze the detection rate of a single optical telescope, 152 out of 412 active satellites and 135 out of 288 inactive satellites in the GSO region were selected on the basis of their visibility at the observation site in Daejeon, Korea. By using various vertical view ranges and various numbers of observations of the GSO region, the detection efficiencies were analyzed for a single night, and the numbers of follow-up observations were determined. The orbital estimation accuracies were also checked using the arc length and number of observed data points to maintain the GSO satellite catalog.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

The Influence of Mixed Solvents Volatility on Charge State Distribution of Peptides During Positive Electrospray Ionization Mass Spectrometry

  • Nielsen, Birthe V.;Abaye, Daniel A.;Nguyen, Minh T.L.
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.29-33
    • /
    • 2017
  • Understanding the mechanisms that control and concentrate the observed electrospray ionisation (ESI) response from peptides is important. Controlling these mechanisms can improve signal-to-noise ratio in the mass spectrum, and enhances the generation of intact ions, and thus, improves the detection of peptides when analysing mixtures. The effects of different mixtures of aqueous: organic solvents (25, 50, 75%; v/v): formic acid solution (at pH 3.26) compositions on the ESI response and charge-state distribution (CSD) during mass spectrometry (MS) were determined in a group of biologically active peptides (molecular wt range 1.3 - 3.3 kDa). The ESI response is dependent on type of organic solvent in the mobile phase mixture and therefore, solvent choice affects optimal ion intensities. As expected, intact peptide ions gave a more intense ESI signal in polar protic solvent mixtures than in the low polarity solvent. However, for four out of the five analysed peptides, neither the ESI response nor the CSD were affected by the volatility of the solvent mixture. Therefore, in solvent mixtures, as the composition changes during the evaporation processes, the $pK_b$ of the amino acid composition is a better predictor of multiple charging of the peptides.

The Study of Egg Transports and distribution Patterns in the Oviducts of Superovulated Rabbits by Administrations of $PGF_{2\alpha}$ (Prostaglandin $F_{2\alpha}$ 처리에 따른 과배란 가토의 난관내 난자운반 및 분포에 관한 연구)

  • 변태호;심금섭;이재근
    • Korean Journal of Animal Reproduction
    • /
    • v.8 no.1
    • /
    • pp.10-15
    • /
    • 1984
  • This experiment was carried out to study the egg transports and distribution patterns in the oviducts of superovulated rabbits by administrations of PGF2$\alpha$. Group I (3 does) and Group II (3 does) were killed at 24 hours, 48 hours after mating, respectively. Group III (6 does0 received a single injection of 5mg/Kg of body weight of PGF2$\alpha$ at 24 hours after mating and killed at 4 hours after PGF2$\alpha$ administration. The oviducts were frozen in LN-gas, thawed using Howe's method, and cleared in Benzyl-Benzoate sol. using Orsini's technique. The location of the eggs and the AIJ. were identified using transmitted light from a dissecting microscope. The results obtained were as follows: 1. The average numbers of detected eggs from the oviduct were 28.6 (26-32), 26.0 (24-29), and 27.1 (22-34) in Group I, II, and III, respectively. 2. Detection rate was 88.7%, 76.4%, and 84.9% in Group I, II, and III, respectively. 3. The positionof all AIJ. was 44.2% to 55.0%(av. 49.5%) of the distance from the fimbriae to the UTJ.(Utero-Tubal Junction). 4. The changes of egg distribution patterns were as follows: Group I Ampulla : 52.3%, Isthmus : 47.7%, Group II Ampulla : 8.9%, Isthmus : 91.1% Group III Ampulla : 8.0% Isthmus : 92.0%.

  • PDF

A Study for Source and Distribution of Boron in Nakdong River (낙동강 수역의 붕소 오염원과 분포특성 연구)

  • Lee, Joung-Man;Park, Chung-Kil;Kim, Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.236-241
    • /
    • 2005
  • The purpose of this study is to find out the source(s) and distribution of boron in Nak-dong River. In the year of 2002, the boron has been adopted as a toxic constituent for Korean drinking water standard. In this study, the analytical samples were collected at 11 stations in March, June, September and December 2002. These samples were analyzed by inductively coupled plasma-mass (ICP-MS) method. The recovery, relative standard deviation and method detection limit of the ICP-MS method for boron was $89{\sim}111.3%$, $2.21{\sim}3.81%$ and $5{\mu}g/L$, respectively. The distribution of boron was ranged $65{\sim}155{\mu}g/L$ in March, $26{\sim}125{\mu}g/L$ in June, $22{\sim}140{\mu}g/L$ in September and $50{\sim}162{\mu}g/L$ in December. The higher levels of boron were found at Kum-ho river nearby the industrial complex, which seemed to be greatly affected by domestic sewages and wastewater from the upper streams. Thus, the concentration of boron and that of other components showed strong statistical correlation in this area. In the Nak-dong River, industrial wastewater and domestic sewages is thought to be the sources of boron.

Texture Analysis Algorithm and its Application to Leather Automatic Classification Inspection System (텍스처 분석 알고리즘과 피혁 자동 선별 시스템에의 응용)

  • 김명재;이명수;권장우;김광섭;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.363-366
    • /
    • 2001
  • The present process of grading leather quality by the rare eyes is not reliable. Because inconsistency of grading due to eyes strain for long time can cause incorrect result of grading. Therefore it is necessary to automate the process of grading quality of leather based on objective standard for it. In this paper, leather automatic classification system consists of the process obtaining the information of leather and the process grading the quality of leather from the information. Leather is graded by its information such as texture density, types and distribution of defects. This paper proposes the algorithm which sorts out leather information like texture density and defects from the gray-level images obtained by digital camera. The density information is sorted out by the distribution value of Fourier spectrum which comes out after original image is converted to the image in frequency domain. And the defect information is obtained by the statistics of pixels which is relevant to Window using searching Window after sort out boundary lines from preprocessed images. The information for entire leather is used as standard of grading leather quality, and the proposed algorithm is practically applied to machine vision system.

  • PDF

Defects Detection of the Underground Distribution Power Cables by Very Low Frequency Voltage Source (초저주파전원을 이용한 지중배전 전력케이블의 결함검출)

  • 김주용;송일근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.45-50
    • /
    • 1998
  • This paper presents experimental results on the application of very low frequency(VLF) voltage to replace conventional DC test as an after laying test for underground distribution cables. We carried out several tests to prove defects detecting ability of VLF test on the 5m length real cables having knife-cut or needle type defects which is made in our La.. Through this experiment we proved it is very difficult to initiate electrical tree from the defects inside of the cable insulation but once the electrical tree is initiated it grows very fast and VLF does not make new defects and expand the defect. Therefore VLF test equipment for quality inspection test of manufacture is more effective than field application for underground distribution cables.

  • PDF

Determination of Frequency of Epstein-Barr Virus in Non-Hodgkin Lymphomas Using EBV Latent Membrane Protein 1 (EBV-LMP1) Immunohistochemical Staining

  • Ishtiaq, Sheeba;Hassan, Usman;Mushtaq, Sajid;Akhtar, Noreen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3963-3967
    • /
    • 2013
  • Background: The presence of Epstein-Barr virus (EBV) in Non-Hodgkin's lymphoma can be identified by immunohistochemistry for detection of EBV latent membrane protein (LMP). The role of EBV as an etiologic agent in the development of non-Hodgkin lymphoma has been supported by detection of high levels of latent membrane protein 1 (LMP-1) expression in tumors. However, no study has been conducted in a Pakistani population up till now to determine the frequency of Epstein-Barr virus positivity. The objective of our study was to determine a value for non-Hodgkin lymphoma patients using EBV LMP-1 immunostaining in our institution. Materials and Methods: This study was carried out at the Department of Histopathology, Armed Forces Institute of Pathology (AFIP), Pakistan from December 2011 to December 2012. It was a cross sectional study. A total of 71 patients who were diagnosed with various subtypes of NHL after histological and EBV LMP-1 immunohistochemical evaluation were studied. Sampling technique was non-probability purposive. Statistical analysis was achieved using SPSS version 17.0. Mean and SD were calculated for quantitative variables like patient age. Frequencies and percentages were calculated for qualitative variables like subgroup of NHL, results outcome of IHC for EBV and gender distribution. Results: Mean age of the patients was $53.6{\pm}16$ years (Mean${\pm}$SD). A total of 50 (70.4%) were male and 21 (29.6%) were female. Some 9 (12.7%) out of 71 cases were positive for EBV-LMP-1 immunostaining, 2 (22.2%) follicular lymphoma cases, 1 (11.1%) case of T-cell lymphoblastic lymphoma, 4 (44.4%) cases of diffuse large B cell lymphomas, 1 (11.1%) mantle cell lymphoma and 1 (11.1%) angioimmunoblastic T cell lymphoma case. Conclusion: In our study, frequency of EBV in NHL is 12.7% and is mostly seen in diffuse large B cell lymphoma. This requires further evaluation to find out whether this positivity is due to co-infection or has a role in pathogenesis.