• 제목/요약/키워드: Oscillation system

검색결과 757건 처리시간 0.026초

용량형 마이크로 공진기의 주파수 응답 보상 기법 (Frequency Response Compensation Technique for Capacitive Microresonator)

  • 서진덕;임교묵;고형호
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.235-239
    • /
    • 2012
  • This paper presents frequency response compensation technique, and a self-oscillation circuit for capacitive microresonator with the compensation technique using programmable capacitor array, to compensate for the frequency response distorted by parasitic capacitances, and to obtain stable oscillation condition. The parasitic capacitances between the actuation input port and capacitive output port distort the frequency response of the microresonator. The distorted non-ideal frequency response can be compensated using two programmable capacitor arrays, which are connected between anti-phased actuation input port and capacitive output port. The simulation model includes the whole microresonator system, which consists of mechanical structure, transimpedance amplifier with automatic gain control, actuation driver and compensation circuit. The compensation operation and oscillation output of the system is verified with the simulation results.

Analytic Modeling of the Xenon Oscillation Due to Control Rod Movement

  • Song, Jae-Seung;Cho, Nam-Zin;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.80-87
    • /
    • 1999
  • An analytic axial xenon oscillation model was developed for pressurized water reactor analysis. The model employs an equation system for axial difference parameters that was derived from the two-group one-dimensional diffusion equation with control rod modeling and coupled with xenon and iodine balance equations. The spatial distributions of nu, xenon, and iodine were expanded by the Fourier sine series, resulting in cancellation of the flux-xenon coupled non-linearity. An inhomogeneous differential equation system for the axial difference parameters, which gives the relationship between power, iodine and xenon axial differences in the case of control rod movement, was derived and solved analytically. The analytic solution of the axial difference parameters can directly provide with the variation of axial power difference during xenon oscillation. The accuracy of the model is verified by benchmark calculations with one-dimensional reference core calculations.

  • PDF

DFT 알고리즘을 이용한 전력계통 동요모드 확인 (Identification of Power System Oscillation Using DFT Algorithm)

  • 김동준;문영환;金容鶴;윤용범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권5호
    • /
    • pp.218-224
    • /
    • 2001
  • This paper describes the identification of torsional modes and power oscillation modes including the inter-area modes and local modes of KEPCO using the proposed DFT analysis algorithm which is applied to the digitally recorded RMS values of power system variables such as steady-state measured active power, load angle and so on. As a result, the inter-area mode of 0.65Hz and the local modes of the three different generators were identified. In addition the torsional modes of two steam-turbo generators were analyzed by applying the DFT algorithm. Thus, this paper clearly shows the availability of the proposed DFT algorithm that can analyze the digitally recorded effective values measured from the equipment such as PMU of DSM.

  • PDF

강제동요 시험을 이용한 모형 계류삭의 동적 응답 연구 (A Research on Dynamic Tension Response of Model Mooring Chain by Forced Oscillation Test)

  • 김현조;홍사영;홍섭;조석규
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.134-141
    • /
    • 2002
  • A series of forced oscillation test on model mooring chain was carried out to investigate dynamic tension characteristics. The model test was conducted at two different water depth to gather basic data for 'truncated mooring test' and 'hybrid mooring test'. The truncated and hybrid mooring test are highly recommended to overcome the limitation of water depth in model test recently. The resultant tension RAO gives good possibility of approximation of dynamic tension by equivalent weight adjustment for the ratio of water depth in different water depth. Because the hybrid mooring test is the adequate combination of model test and simulation, accurate simulation model on mooring system is essential. The simulation results show good agreement with model test results.

  • PDF

OSCILLATION CRITERIA FOR SECOND-ORDER NONLINEAR DIFFERENCE EQUATIONS WITH 'SUMMATION SMALL' COEFFICIENT

  • KANG, GUOLIAN
    • 대한수학회보
    • /
    • 제42권2호
    • /
    • pp.245-256
    • /
    • 2005
  • We consider the second-order nonlinear difference equation (1) $$\Delta(a_nh(x_{n+1}){\Delta}x_n)+p_{n+1}f(x_{n+1})=0,\;n{\geq}n_0$$ where ${a_n},\;{p_n}$ are sequences of integers with $a_n\;>\;0,\;\{P_n\}$ is a real sequence without any restriction on its sign. hand fare real-valued functions. We obtain some necessary conditions for (1) existing nonoscillatory solutions and sufficient conditions for (1) being oscillatory.

TCSC의 주기적 스위칭 동작에 의한 진동모드의 감도해석 (Sensitivity analysis of oscillation modes occurred by periodic switching operations of TCSC)

  • 김덕영;동무환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.644-645
    • /
    • 2007
  • In this paper, the eigenvalue sensitivity analysis algorithm in discrete systems by the RCF method are presented and applied to the power system including TCSC. The RCF analysis method enabled to precisely calculate eigenvalue sensitivity coefficients of dominant oscillation modes after periodic switching operations. These simulation results are very different from those of the conventional continuous system analysis method such as the state space equation method

  • PDF

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

음향 가진을 이용한 매달려 있는 액적의 형상 진동 모드에 관한 실험적 연구 (An Experimental Study on Shape Oscillation Mode of a Pendant Droplet by an Acoustic Wave)

  • 강병하;문종훈;김호영
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.523-530
    • /
    • 2006
  • One of the fascinating prospects is the possibility of new hydrodynamics technology on micro-scale system since oscillations of micro-droplets are of practical and scientific importance. It has been widely conceived that the lowest oscillation mode of a pendant droplet is the longitudinal vibration, i.e. periodic elongation and contraction along the longitudinal direction. Nonlinear and forced oscillations of supported viscous droplet were focused in the present study. The droplet has a free contact line with solid plate and inviscid fluid. Natural frequencies of a pendant droplet have been investigated experimentally by imposing the acoustic wave while the frequency is being increased at a fixed amplitude. It is found that a pendant droplet shows the resonant behaviors at each mode similar to the theoretical analysis. The rotation of the droplet about the longitudinal axis is the oscillation mode of the lowest resonance frequency. This rotational mode can be invoked by periodic acoustic forcing and is analogous to the pendulum rotation. It is also found that the natural frequency of a pendant droplet is independent of the drop density and surface tension but inversely proportional to the square root of the droplet size.

High Frequency Variation of Low Water Temperature due to Arctic Oscillation Around the Western and Southern Coast of Korea During Winter 2017/2018

  • Han, In-Seong;Lee, Joon-Soo;Kim, Ju-Yeon;Hong, Ji-Yeon
    • 해양환경안전학회지
    • /
    • 제25권3호
    • /
    • pp.328-333
    • /
    • 2019
  • During the winter of 2017/2018, significantly low water temperatures were detected around the western and southern coasts of Korea (WSCK). In this period, sea surface temperature (SST) in the Korea Waters was about $2^{\circ}C$ lower than mean temperature. Using the real-time observation system, we analyzed the temporal variation of SST during this period around the western and southern coasts. Low water temperature usually manifested over a period of about 10 ~ 20 days. The daily Arctic oscillation index was also similarly detectable with the variation of SST. From the cross-correlation function, we compared two periodic variations, which were SST around the WSCK and the Arctic oscillation index. The cross correlation coefficients between both variations were approximately 0.3 ~ 0.4. The time lag of the two time series was about 6 to 7 days. Therefore, significantly low water temperatures during winter in the Korean coastal areas usually became detectable 6 to 7 days after the negative peak of Arctic oscillation.

Power Control Strategies for Single-Phase Voltage-Controlled Inverters with an Enhanced PLL

  • Gao, Jiayuan;Zhao, Jinbin;He, Chaojie;Zhang, Shuaitao;Li, Fen
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.212-224
    • /
    • 2018
  • For maintaining a reliable and secure power system, this paper describes the design and implement of a single-phase grid-connected inverter with an enhanced phase-locked loop (PLL) and excellent power control performance. For designing the enhanced PLL and power regulator, a full-bridge voltage-controlled inverter (VCI) is investigated. When the grid frequency deviates from its reference values, the output frequency of the VCI is unstable with an oscillation of 2 doubling harmonics. The reason for this oscillation is analyzed mathematically. This oscillation leads to an injection of harmonics into the grid and even causes an output active power oscillation of the VCI. For eliminating the oscillation caused by a PLL, an oscillation compensation method is proposed. With the proposed method, the VCI maintains the original PLL control characteristics and improves the PLL robustness under grid frequency deviations. On the basis of the above analysis, a power regulator with the primary frequency and voltage modulation characteristics is analyzed and designed. Meanwhile, a small-signal model of the power loops is established to determine the control parameters. The VCI can accurately output target power and has primary frequency and voltage modulation characteristics that can provide active and reactive power compensation to the grid. Finally, simulation and experimental results are given to verify the idea.