• Title/Summary/Keyword: Orthosis

Search Result 167, Processing Time 0.033 seconds

Effects of Korean Medicine Treatment on a Patient with Functional Scoliosis with an Abnormal Gait Pattern After Hip Injury: A Case Report

  • Gi, Yu-Mi;Kim, Tae-Gyu;Jo, Hoo-In;Choi, Jong-Ho;Park, Eun-Young;Lee, Soo-Kyung;Lee, June-Haeng;Kim, Min-Kyu;Lee, KeunJae;Yu, Ok-Cheol
    • Journal of Acupuncture Research
    • /
    • v.36 no.4
    • /
    • pp.282-285
    • /
    • 2019
  • Scoliosis is a 3-dimensional spinal deformity defined as lateral curvature of the spine in the coronal plane of more than $10^{\circ}$. This study describes a case of functional scoliosis after hip injury. In this case, the patient fell whilst inline skating (June 2015) causing severe tilting of her spine, and left hip pain. She received outpatient treatment from July 14, 2015 to December 28, 2015. For approximately 5 months, acupuncture therapy was performed to relax the tension in both hips, Chuna therapy, and foot orthosis were applied to reduce the body's imbalance. Based on X-ray images, the Cobb angle had decreased from $14.73^{\circ}$ (pretreatment) to $1.90^{\circ}$ (posttreatment). This case report suggested that Korean medicine treatment could be an effective therapeutic choice for functional scoliosis.

Effect of Wearable Passive Back Support Exoskeleton on the Peak Muscle Activation of the Erector Spinae Muscles During Lifting

  • Hee-Eun Ahn;Tae-Lim Yoon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Background: Using wearable passive back-support exoskeletons in workplace has attracted attention as devices that support the posture of workers, enhance their physical capabilities, and reduce physical risk factors. Objects: This study aimed to investigate the effect of a wearable passive back-support exoskeleton on the activity of the erector spinae muscles during lifting tasks at various heights. Methods: Twenty healthy adult males were selected as subjects. Electromyography (EMG) was used to assess the activity of the erector spinae muscles while performing lifting tasks at three distinct heights (30, 40, and 50 cm), with and without the application of the Wearable Passive Back Support Exoskeleton. EMG data were gathered before and after the application of the orthosis. Results: The use of the Wearable Passive Back Support Exoskeleton resulted in a significant decrease in muscle activity when lifting a 10 kg object from heights of 30 and 40 cm (p < 0.05). Additionally, there was a significant reduction in muscle activity when lifting from a height of 50 cm compared with that at lower heights (p < 0.05). Conclusion: The use of a wearable passive back-support exoskeleton led to a decrease in the activity of the erector spinae muscles during lifting tasks, irrespective of the object's height. Our results suggest that the orthosis we tested may help decrease risk of lower back injuries during lifting.

Effects of Gait Training Using a Shoulder-Back Orthosis on Balance and Gait in Patients with Stroke

  • Han-Byul Youn;Jong-Kyung Lee;Yu-Min Ko;Ji-Won Park
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.200-205
    • /
    • 2023
  • Purpose: The purpose of this study is to find out how gait training with shoulder-back assistive device affects dynamic and static balance, gait of patients with stroke and to help improve body alignment, balance, and gait ability in stroke patients. Methods: Measurements were taken of the 20 subjects before intervention without shoulder-back assistive device, after intervention with device, and follow up after an hour compared. Berg balance scale used to evaluate dynamic balance; wii balance board was used to measure static balance; and gait ability were measured by timed up and go test and 10-meter walk test. To analyze the results, a one-way repeated measures analysis of variance was implemented to compare the measurements. Results: The results showed that, after wearing the shoulder-back assistive device, the subjects' dynamic balance statistically significantly improved; no statistically significant difference was observed in static balance, although their balance ability was enhanced; and their increase in gait ability was statistically significant. Conclusion: This study proved that gait training combined with a shoulder-back assistive device positively impacted dynamic and static balance, gait of patients with stroke.

Efficacy of a Knee Walker for Foot and Ankle Patients: Comparative Study with an Axillary Crutch (족부 족관절 환자에서 Knee Walker의 유용성: 액와 목발(Axillary Crutch)과의 비교 연구)

  • Song, Jae Hwang;Kang, Chan;Kim, Sang Bum;Heo, Youn Moo;Won, You Gun;Jung, Sang Jin;Chung, Hyung Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.100-104
    • /
    • 2018
  • Purpose: An axillary crutch is the most commonly used assistive device in foot and ankle patients who require nonweightbearing. On the other hand, its use frequently induces axillary or wrist pain and critical neurovascular injuries have been reported in several studies. This study compared the clinical outcomes of patients using the knee walker and axillary crutch. Materials and Methods: A retrospective analysis was performed comparing the utility of a knee walker and axillary crutch as a nonweightbearing ambulatory aid for 62 foot and ankle patients treated between November 2016 and March 2018. A comparative study of the two orthosis could be performed because all the patients temporarily used an axillary crutch before or after the use of a knee walker. A demographic study and comparative analysis based on the visual analogue scale (VAS) satisfaction score (0~100), complications, and fall down history were evaluated. Furthermore, under the assumption of having retreatment, their preference of orthosis between the knee walker and axillary crutch was investigated. Results: The mean age of the patients was 36.5 and the mean duration of ambulation with a knee walker and axillary crutch were 5.2 and 2.4 weeks. The VAS satisfaction score of the knee walker and crutch was 88.8 and 27.5, respectively (p<0.05). The most frequent complications of the knee walker and crutch were ipsilateral knee pain (6 cases) and axillary or wrist pain (56 cases), respectively. No case of falling down occurred during knee walker ambulation, but there were two cases of crutch ambulation. Fifty-eight patients (93.5%) preferred the knee walker and four patients (6.5%) preferred a crutch. Conclusion: Compared to the axillary crutch, the knee walker afforded lower complication and higher satisfaction. Most patients preferred the knee walker to a crutch. Therefore, the knee walker is an efficient and safe orthosis for foot and ankle patients who require nonweightbearing.

Effects of Self-care Program on Exercise performance Self-Efficay, Self-care Knowledge, Self-care Performance in Patients with Lumbar Discectomy (자가간호프로그램이 요추간판제거술 환자의 운동이행 자기효능감, 자가간호지식, 자가간호이행에 미치는 효과)

  • Jeong, Jin-Hee;Lee, Hye-Kyung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.891-902
    • /
    • 2021
  • This study is an experimental study to confirm the effect of self-care program on exercise performance self-efficacy, Knowledge of self-management and Performance of self-management in patients with lumbar disc removal. The subjects were 26 inpatients in the experimental group and 27 in the control group as inpatients at the D City Material Spine Hospital. The collected material was analyzed using the SPSS 25.0 program with mean, percentage, standard deviation, t-test, x2-test, Independent t-test, and repeated measures ANOVA. Hypothesis that after self-care program mediation, the experimental group had higher scores for orthosis management knowledge (p<.001) and daily life management knowledge (p=.005) as time passed compared to the unprovided control group. The hypothesis is that the experimental group provided with the self-care program has a performance of orthosis management(p=.011), higher degree of orthosis management performance (p=.011) and daily life management performance (p=.007) than the non-provided control group. Was supported. There, it was confirmed that it is an effective self-care program that can be easily applied at home to patients with lumbar disc removal from the day before surgery to after discharge.

The Effects of Treadmill Gait Training with Flexible Derotator of Femur Orthosis on Postural Alignment of Lower Extremities and Gait in Children with Cerebral Palsy: Single Group Rpeated Measure Design (대퇴골 회전방지보조기를 착용한 트레드밀 보행훈련이 뇌성마비 아동의 하지배열 및 보행에 미치는 영향: 단일그룹 반복측정 연구)

  • Yoo, Hyun-Young;Kim, Suhn-Yeop;Jang, Hyun-Jung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effects of flexible derotator of femur orthosis (FDO) during treadmill gait training on the quadriceps-angle (Q-angle), lateral pelvic tilt, gait speed, and number of steps in children with cerebral palsy. METHODS: Seven children with cerebral palsy who had rotational deformity of the lower extremities participated in this study. We used single group repeated measure design. The procedure consisted of baseline phase, intervention phase, and post-intervention phase. The baseline phase consisted of stretching and strengthening exercise and treadmill gait training without FDO. The treatment phase not only included the same procedures as those for baseline, but also included FDO during treadmill gait training. Postural alignment of the lower extremities was assessed with the Q-angle, and lateral pelvic tilt using the Dartfish software program. A 10-m walk test was used to evaluate gait speed and number of steps. RESULTS: For postural alignment, there was significant differences after the application of FDO (p<.05). For gait ability, there was significant differences in all phases (p<.01). CONCLUSION: These finding suggest that the application of FDO during treadmill gait training had a positive effect on the improvement of postural alignment and gait ability in children with cerebral palsy having rotational deformity.

The First Neurosurgical Analysis of 8 Korean Children with Sotos Syndrome

  • Lim, Jae-Joon;Yoon, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.240-244
    • /
    • 2008
  • Objective : Sotos Syndrome is characterized by macrocephaly, overgrowth, and developmental delay, and more than 300 patients have been reported worldwide to date. The authors reviewed the clinical characteristics of 8 patients with Sotos Syndrome in Korea for a new understanding and treatment strategies. Methods : The medical records of a total of eight Korean children with Sotos Syndrome were reviewed. All patients underwent developmental checkup, lumbar punctures for measurement of intracranial pressure (ICP), brain and spine magnetic resonance imaging and computerized tomography. Results : All 8 patients showed macrocephaly and the characteristic craniofacial features of Sotos Syndrome. Other clinical characteristics shown were overgrowth (7/8), developmental delay (7/8), congenital heart defect (3/8), flat foot (8/8), scoliosis (4/8), spina bifida (8/8), hydrocephalus (4/8), cavum vergae (3/8), and increased subdural fluid collection (5/8). Mean ICP measured via lumbar puncture was $27.35{\pm}6.25\;cm$ $H_2O$ (range 20 to 36 cm $H_2O$). Two patients received ventriculo-peritoneal shunt, and 1 patient underwent subduro-peritoneal shunt with improvement. Spinal orthosis was applied to 4/5 patients with scoliosis and 4/8 children with flat foot were provided with foot orthosis. Conclusion : In this first Korean study of 8 Sotos Syndrome patients we demonstrated the presence of spina bifida and increased ICP, which had not been previously described. The authors therefore suggest that all patients with Sotos Syndrome should undergo examination for the presence of spina bifida, and that shunt procedures would improve development and alleviate clinical symptoms.