• Title/Summary/Keyword: Orthodontic wire

Search Result 143, Processing Time 0.026 seconds

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD (유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구)

  • Lee, Won-You;An, Ju-Sam;Park, Young-Cheol;Park, Myeong-Kyun;Sohn, Hong-Bum;Jeong, Si-Dong
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.43-49
    • /
    • 1998
  • The aim of this study were to measure and compare the stress level on three type brackets and each other material (stainless steel, ceramic) with tipping and torquing forces by using the finite element analysis and to design biomechanically favorable brackets. For this study, three kinds of brackets were selected(A:Transcend-RMO, B:Signature-Unitek, C:PAW: plain archwire appliance-applied for a patent in Yonsei Udiversity). The slot size of bracket was 0.022inch and the size of archwire was 0.0175x0.025inch and taper shaped archwire was used in PAW. Loading force in tipping was 4.27N and torquing force was 32.858N applied by archwire torsion with 19.7degree and 11.3 degree in C type bracket. The conclusions were that (1) The finite element method proved to be a useful tool in the stress analysis of orthodontic bracket subjected to various forces. (2) With tipping, the stresses were concentrated at the gingival wall of the wire slot where it meets the mesial bracket surface and the incisal wall of the wire slot where it meets the distal bracket surface and with torquing, the stresses were concentrated at the junction of the gingival or incisal wall and base of the slot. (3) The maximum stress value was higher in torquing force than tipping force and therefore it is desirable to design on the basis of torquing force. (4) It was considered that the change in material might be affect on the diminish of stress value in the place of stess concentration. (5) The maximum stress value was highest on PAW bracket when the tipping and torquing force was applied and therefore it would be desirable to use mechanically favorable material on PAW bracket.

  • PDF

THE ROOT RESORPTION AND THE PERIODONTAL TISSUE CHANGE AFTER ORTHODONTIC TOOTH MOVEMENT OF THE VITAL AND ENDODONTICALLY TREATED TOOTH IN THE DOG (실활치의 교정적 치아이동시 치근 및 치주조직의 변화에 관한 실험적 연구)

  • Shim, Won Seop;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.20 no.3 s.32
    • /
    • pp.447-462
    • /
    • 1990
  • The objective of this experiment is to observe structural differences in the othodontic movement of vital (control group) and devitalized (experimental group) teeth in the mongrel dogs. The 5 utilized dogs in this experiment were approximately 1 year of age and their average weight was about 12 Kg. Endodontic therapy was performed on the 2nd premolars in upper & lower jaws of each animal under the general anesthesia by intravascular injection of 25mg/kg of pentobarbital sodium. The canals of the teeth were obturated by using gutta percha in conjunction with root canal sealer (AH26 Densply). One of the roots in the 2nd premolars was hemisected to make an extraction space for the devitalized teeth to be moved. The edgewise technique was employed for the movement of the teeth. Orthodontic models and intraoral roentgenograms were taken before and after orthodontic tooth movement. The open coil springs (.010 x .040) were used at interbraket space in order to provide equal forces (75gm) between the teeth in each arch wire. After 13 weeks of active orthodontic tooth movement, dogs were sacrified and the experimental results w ere examined through the intraoral radiography, microscopic examination and scanning electromicroscopic examination at the root sulfate. From the results of the study, the following conclusions may be drawn: The root resolution and cemental deposition were observed within the pressure and tension site in both group. 2. The root resorbed lacunae were observed in the cementum and/or into the dentin in both group. 3. The prominent osteoblastic activities were observed on the alveolar margin in the tension site in both group. 4. A few of blood vessels were observed in the pressure site, but also lots of blood vessels were observed in the tension site especially in the periphery of the alveolar bone in both group. 5. In the pressure site, resorbed lacunae were formed with deep and narrow cavity in the control group; the shallow and wide cavity in the experimental group. 6. In the pressure site, the repaired cementum or cementoid tissue was lined on cementum in the experimental group, but not in the control group. 7. There was no significant difference between external root resolution of endodontically and vital teeth when both were subjected to orthodontic forces.

  • PDF

A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions (교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구)

  • Lee, Jin-Woo;Cha, Kyung-Suk;Han, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.271-281
    • /
    • 2001
  • The Purpose of this study was fourfold - to evaluate the general laws of friction applied to orthodontic conditions, to compare archwire materials under these controlled conditions, to compare ligation method, and to measure the effect of the artificial saliva on friction with these materials Three wire alloys (Cobalt-chromium, Nickel-titanium, Beta-titanium) in two size wires (.016" , .016" ${\times}$.022" ) were examined respect to the bracket (.018" ${\times}$.025" standard), and two ligature material (stainless steel, elastomeric) in dry and wet conditions The results were as follows, 1. The order of frictional force against alloy materials was Co-Cr (lowest), Ni-Ti, and ${\beta}$-Ti(highest) - with the exception of elastomeric ligation under wet conditions. 2. S.S. ligation gave rise to significantly greater friction than elastomeric ligation did. 3. Testing in the presence of saliva, rather than in dry conditions, decreased the frictional force for S.S. ligation with .016" Co-Cr, Ni-Ti, ${\beta}$-Ti. but, increased the frictional force for S.S. ligation with .016" ${\times}$ .022" Co-Cr, Ni-Ti, ${\beta}$-Ti. 4. .016" ${\times}$.022 " wire generated more friction than .016" wire.

  • PDF

The Frictional Resistance Of Tin Ion-Plated Co-Cr Orthodontic Wire (TiN 피막처리된 Co-Cr계 교정용 선재의 마찰저항력)

  • Lee, Ho-Kyu;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.123-133
    • /
    • 1998
  • The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(.016“, .016”x.022“) on three different types of bracket(TiN ion-plated metal bracket ceramic bracket and plastic bracket). Maximum static frictional forces and characteristic curves obtained from the frictional characteristic graph, were compared and surface roughness of wires and bracket slots before and after friction experiment was observed by SEM. The obtained results were as follows $\cdot$The frictional forces of TiN ion-plated wires were significantly lower than those of non ion-plated wires(p<0.05). $\cdot$On the effect of wire shape, the frictional forces of round wires were significantly lower than those of rectangular wires(p<0.05) $\cdot$As the result of the SEM observation on the wires and bracket slots after the friction experiment the surface of non ion-plated wires was rougher than that of TiN ion-plated ones. $\cdot$The difference between the static frictional forces and the kinetic frictional forces was not significant in case of the TiN ion-plated round ins, but the static frictional forces were a little higher than the kinetic frictional forces in the TiN ion-plated rectangular wires. $\cdot$The static frictional forces were much higher than the kinetic frictional forces in the case of non ion-plated wires.

  • PDF

AN ANALYSIS OF STRESS DISTRIBUTION IN THE CASE OF UNILATERAL MOLAR EXPANSION WITH PRECISION LINGUAL ARCH BY FINITE ELEMENT METHOD (구치 편측확장을 위한 Precision Lingual Arch 적용시 응력분포에 관한 유한요소법적 연구)

  • Koo, Bon-Chan;Sohn, Byung-Wha
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.721-733
    • /
    • 1994
  • Orthodontic tooth movement is closely related to the stress on the periodontal tissue. In this research the finite element method was used to observe the stress distribution and to find the best condition for effective tooth movement in the case of unilateral molar expansion. The author constructed the model of lower dental arch of average Korean adult and used $.032'\times.032'\times60mm$ TMA wire. The wire was deflected in the horizontal and vertical direction to give the 16 conditions. The following results were obtained ; 1. When the moment and force were controlled properly the movement of anchor tooth was minimized and the movement of moving tooth was maximized. 2. As the initial horizontal deflection increased the buccal displacement of both teeth was also increased. As the initial horizontal deflection increased the lingual movement of anchor tooth and the buccal movement of moving tooth increased. 3. When the initial horizontal and vertical deflection rate was 1.5 the effective movement of moving tooth was observed with minimal displacement of anchor tooth.

  • PDF

The effect of occlusogingival placement of clinical bracket points on the adaptation of a straight wire to the lingual arch form

  • Abdi, Amir Hossein;Motamedian, Saeed Reza;Balaghi, Ehsan;Nouri, Mahtab
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.236-244
    • /
    • 2018
  • Objective: The aim of this study is to compare the adaptation of a straight wire between brackets positioned at the mid-lingual surface and those placed gingivally by using a three-dimensional simulation software. Methods: This cross-sectional study was performed using OrthoAid, an in-house software. The subjects were 36 adolescents with normal Class I occlusion. For each dental cast, two bracket positioning approaches, namely the middle and gingival, were examined. In the middle group, the reference points were placed on the mid-lingual surface of each tooth, while in the gingival group, the reference points were positioned lingually on the anterior teeth. A 4th degree polynomial was adopted, and the in-plane and off-plane root mean squares (RMSs) of the distances between the reference points and the fitted polynomial curve were calculated using the software. Statistical analysis was performed using the paired-samples t-test (${\alpha}=0.05$). Results: The mean in-plane RMS of the polynomial curve to the bracket distance in the gingival group was significantly lower than that in the middle group (p < 0.001). The off-plane RMS was higher in the gingivally positioned brackets in the maxilla than in the middle group (p < 0.001). However, the off-plane RMS in mandible was not statistically significantly different between the two groups (p = 0.274). Conclusions: The results demonstrated that the gingival placement of lingual brackets on the anterior teeth could decrease the distance between a tooth and the straight wire.

TREATMENT OF THE IMPACTED LOWER SECOND MOLARS (매복된 하악 제2대구치 맹출유도의 치험례)

  • Hahn, Soo-Kyoung;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In the normal growth and development of the mandible, the molar tooth buds distal to the first permanent molar have a mesial inclination. This inclination is usually self-correcting, but, unfortunately, this self-correction does not always occur. The first case is about, 14-year-old female patient with familial history of lower second molar impaction. Her lower second molars were both impacted, and she was treated with sectional wires and open-coil springs. The second case, 14-year-old male, we treated his impacted #47 with Halterman appliance. The third case, 11-year-old male, his both mandibular second molars were impacted during full-fixed orthodontic treatment. They were treated with brass wire, sectional wire and open-coil spring.

  • PDF

Effectiveness of laser-engineered copper-nickel titanium versus superelastic nickel-titanium aligning archwires: A randomized clinical trial

  • Omar Khairullah Ahmed;Ammar Salim Kadhum
    • The korean journal of orthodontics
    • /
    • v.54 no.1
    • /
    • pp.16-25
    • /
    • 2024
  • Objective: To compare the effectiveness of laser-engineered copper-nickel titanium (SmartArch) and superelastic nickel-titanium (SENT) archwires in aligning teeth and inducing root resorption and pain experienced by patients. Methods: Two-arm parallel groups with a 1:1 allocation ratio were used. The participants were patients aged 11.5 years and older with 5-9 mm of mandibular anterior crowding who were indicated for non-extraction treatment. The primary outcome was alignment effectiveness, assessed using Little's irregularity index (LII) over 16 weeks with a single wire (0.016-inch) in the SmartArch group and 2 wires (0.014- and 0.018-inch) in the SENT group (8 weeks each). Secondary outcomes included root resorption evaluated by pre- and post-intervention periapical radiographs and pain levels recorded by the participants during the first week. Results: A total of 40 participants were randomly allocated into 2 groups; 33 completed the study and were analyzed (16 in the SmartArch group and 17 in the SENT group, aged 16.97 ± 4.05 years). The total LII decrease for the SmartArch and SENT groups was 5.63 mm and 5.29 mm, respectively, which was neither statistically nor clinically significant. Root resorption was not significantly different between the groups. The difference in pain levels was not statistically significant for the first 5 days following wire placement; however, there was a significant difference favoring the SENT group in the final 2 days. Conclusions: SmartArch and SENT archwires were similarly effective during the alignment phase of orthodontic treatment. Root resorption should be observed throughout the treatment with either wire. SmartArch wires demonstrated higher pain perception than SENT wires.

Surface Characteristics and Electrochemical Behaviors of TiN and ZrN Coated Orthodontic Mini-screw (ZrN 및 TiN 코팅된 치과교정 용 미니나사의 표면특성과 전기화학적 거동)

  • Kim, S.J.;Moon, Y.P.;Park, G.H.;Jo, H.H.;Kim, W.G.;Son, M.K.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.232-239
    • /
    • 2008
  • The dental orthodontic mini-screw requires good mechanical properties and high corrosion resistance for implantation in the bone. The purpose of this study was to investigate the electrochemical characteristics of TiN and ZrN coated orthodontic mini-screws, mini-screws were used for experiment. Ion plating was carried out for mini-screw using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen w as o bserved with f ield emission scanning e lectron microscopy ( FE-SEM), e nergy dispersive x-ray spectroscopy (EDX), and electrochemical tester. The surface of TiN and ZrN coated mini-screw were more smooth than that of other kinds of non-coated mini-screw due to dercrease of machined defects. The corrosion current density of the TiN and ZrN coated mini-screw decreased compared to non-coated sample. The corrosion potential of TiN and ZrN coated mini-screw were higher than that of non-coated mini-screw in 0.9% NaCl solution. The pitting corrosion resistance increased in the order of ZrN coated, TiN coated and non-coated wire. Pitting potential of ZrN coated mini-screw was the highest in the other specimens.