If the bond strength is sufficient to resist orthodontic force, orthodontic brackets can be bonded to restorations. Orthodontic brackets were bonded to composite resin and glass ionomer cement restorations with no-mix adhesive or glass ionomer cement. The shear bond strength of adhesives bonded to restorations was studied in vitro. Orthodontic brackets were bonded to 10 extracted natural teeth, 40 composite resin restorations and 40 glass ionomer restorations. The surfaces of composite resin restorations were roughened or applied with bonding agent (Scothbond) after surface roughening. The surfaces of glass ionomer cement restorations were conditioned with acid etching or applied with Scotchbond to etched surface. The adhesive was no-mix resin or glass ionomer cement. The shear bond strength was measured. The results were as follows: 1. Orthodontic brackets could be bonded to composite resin restorations effectively as they could be bonded to acid etched enamel with no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was not affected by bonding agent greatly. 2. The shear bond strength of no-mix adhesive bonded to acid etched glass ionomer cement restorations was sufficient to resist orthodontic force. However. the fracture risk of glass ionomer cement restorations was increased during debonding. The bonding agent couldn't increase the shear bond strength greatly. 3. The shear bond strength of glass ionomer cement bonded to glass ionomer cement restorations was lower than that of no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was greatly decreased by bonding agent. 4. The shear bond strength of glass ionomer cement bonded to composite resin restorations was too low to resist orthodontic force.
이 연구의 목적은 지르코니아 기성관에 대한 교정용 밴드의 접착제로서 컴포머 시멘트와 레진 시멘트를 평가하고자 하였다. 총 30개의 시편을 준비하였다. 상악 우측 제 2유구치의 스테인리스 스틸 기성관에 컴포머 시멘트로 교정용 밴드를 접착한 I군과 지르코니아 기성관에 컴포머 시멘트로 밴드를 접착한 II군, 지르코니아 기성관에 레진 시멘트로 밴드를 접착한 III군으로 나누었고 밴드의 결합력을 측정하기 위해 인장력을 가하였다. I군, II군과 III군의 결합력의 평균값은 각각 0.79 MPa, 1.09 MPa 그리고 1.56 MPa였다. II군이 I군보다 유의하게 높은 결합력을 보였고, II군과 III군 의 결합력에는 유의한 차이가 없었다. 컴포머 시멘트와 기능성 단량체를 포함한 레진 시멘트는 유구치 지르코니아 기성관에 대한 교정용 밴드의 시멘트로서 양호한 결합력을 보였다.
Crystal growth 용액인 황화이온을 함유한 폴리아크릴산 용액에 의한 법랑질 표면처리는 법랑질 표면에 crystal growth를 유도함으로써 통상적인 산부식법을 대체하여 교정용 브라켓을 접착하기 위한 법랑질 전처치의 방법으로 사용될 수 있음이 제안된 바 있다. 이 연구는 crystal growth후 교정용 브라켓 접착제로 브라켓을 접착하는 방법의 임상적용 가능성을 구명하기 위하여 시행되었다. 발거된 사람소구치의 법랑질 표면을 $25\%$ 폴리아크릴산과 0.3M 황산을 함유한 기본 crystal growth 용액, 각각 0.3M lithium sulfate, 0.3M magnesium sulfate, 0.3M potassium sulfate를 첨가한 crystal growth 용액, $37\%$ 인산용액, 퍼미스로 각각 처리한 후, 교정용 광중합형 글래스아이오노머 시멘트와 교정용 레진접착제로 금속브라켓을 접착하였다. $37^{\circ}C$의 증류수에 24시간 침지시킨 후, 브라켓 전단결합강도를 측정하고 접착 파절양태를 관찰하였으며 표면처리된 법랑질 표면과 브라켓 제거후의 법랑질 표면을 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. Crystal growth후 광중합형 글래스아이오노머 시멘트로 브라켓 접착시 0.3M magnesium sulfate를 함유한 군의 브라켓 전단결합강도가 가장 높았다(p<0.01). Crystal growth후 광중합형 글래스아이오노머 시멘트로 접착한 군의 브라켓 전단결합강도는 crystal growth 후 레진접착제로 접착한 군보다 높았다(p<0.001). Magnesium sulfate, 또는 potassium sulfate를 함유한 crystal growth 용액으로 법랑질 표면을 처리한 후 글래스아이오노머시멘트로 접착한 군의 브라켓 전단결합강도는 산부식 후 레진 접착제로 접착한 군과 유의한 차이를 보이지 않았다. 브라켓 제거시 잔류접착제의 양은 글래스아이오노머 시멘트로 접착한 것이 가장 적었다. 이상의 결과는 magnesium sulfate나 potassium sulfate를 함유한 crystal growth 용액으로 법랑질 표면처리 후 교정용 광중합형 글래스 아이오노머 시멘트로 브라켓을 접착하는 방법이 통상적으로 사용되는 산부식 후 교정용 레진접착제에 의한 브라켓 접착법을 대체할 수 있음을 시사한다.
목적: 본 연구의 목적은 접착제를 적용하지 않고 치열교정용 브라켓을 접착할 수 있는 레진시멘트의 법랑질에 대한 접착강도를 접착제를 적용한 경우와 비교하기 위함이다. 연구 재료 및 방법: 시편을 Transbond XT, GC Ortho Connect 및 Orthomite LC의 3개의 실험군으로 나누고, 노출된 법랑질 표면을 2분획으로 나누어 한 분획에는 37% 인산으로, 다른 한 분획에는 37% 인산 및 접착제 혹은 유니버셜 접착제로 표면 처리를 하였다. 치열교정용 브라켓에 3 종류의 시멘트를 각각 도포하고 접착을 한 뒤 전단접착강도를 측정하였다. 결과: Transbond XT와 Orthomite LC는 각각 접착제와 유니버셜 접착제를 적용한 후 치열교정용 브라켓을 접착할 경우 전단접착강도가 유의하게 증가하였다. 결론: Transbond XT와 Orthomite LC에서 산 부식 후 접착제의 적용이 치열교정용 브라켓의 전단접착강도를 향상시킬 것으로 기대한다.
Objective: The aims of this study were to compare the shear bond strength between orthodontic metal brackets and glazed zirconia using different types of primer before applying resin cement and to determine which primer was more effective. Methods: Zirconia blocks were milled and embedded in acrylic resin and randomly assigned to one of four groups: nonglazed zirconia with sandblasting and zirconia primer (NZ); glazed zirconia with sandblasting, etching, and zirconia primer (GZ); glazed zirconia with sandblasting, etching, and porcelain primer (GP); and glazed zirconia with sandblasting, etching, zirconia primer, and porcelain primer (GZP). A stainless steel metal bracket was bonded to each target surface with resin cement, and all specimens underwent thermal cycling. The shear bond strength of the specimens was measured by a universal testing machine. A scanning electron microscope, three-dimensional optical surface-profiler, and stereoscopic microscope were used to image the zirconia surfaces. The data were analyzed with one-way analyses of variance and the Fisher exact test. Results: Group GZ showed significantly lower shear bond strength than did the other groups. No statistically significant differences were found among groups NZ, GP, and GZP. All specimens in group GZ showed adhesive failure between the zirconia and resin cement. In groups NZ and GP, bonding failed at the interface between the resin cement and bracket base or showed complex adhesive and cohesive failure. Conclusions: Porcelain primer is the more appropriate choice for bonding a metal bracket to the surface of a full-contour glazed zirconia crown with resin cement.
고정식 교정 치료시 교정용 밴드가 장착된 치아의 치주조직 손상은 접착된 치아에서 보다 자주 발생한다. 일반 치과치료에 사용되는 시멘트는 세포독성을 지닌 것으로 알려져 있으므로 치주조직과 직접 접촉하거나 구강 내에서 밴드시멘트의 성분들이 용출되는 교정용 밴드 시멘트는 치주조직의 손상을 일으키는 원인이 될 수 있다 그러므로 교정용 밴드 시멘트의 생체 친화성은 재료의 물성과 함께 중요하게 고려되어야 할 사항이다. 이 연구의 목적은 교정용 밴드 시멘트의 세포독성을 평가하는 것으로 현재 임상에서 널리 사용되고 있는zinc phosphate cement (ZPC), glass ionomer (GI), resin modified glass ionomer (RMGI), compomer의 생체 친화성을 평가하기 위해 human gingiva fibroblast를 배양하고 이 세포에 대한 세포수 산정 및 세포 형태관찰, MTT(3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay, 한천중층시험 등의 세포독성 검사를 시행하여 다음과 같은 결과를 얻었다. 1. 세포수 산정 및 형태 관찰 시험에서 Gl>ZPC, RMGI, RMG124, GI24>compomer24, ZPC24, compomer 순으로 세포독성이 높게 나타났다. 2. MTT assay 에서는 GI>ZPC, RMGI>GI24>ZPC24, compomer, RMGI24, compomer24 순으로 세포독성이 높게 나타났다. 3. 한천중층시험에서 는 GI>GI24, ZPC, ZPC24, RMGI>RMG124, compomer, compomer24 순으로 세포독성 이 높게 나타났다.
본 연구의 목적은 브라켓 접착 시 산부식과 전처리 과정을 결합하여 접착 단계를 단순화시킨 self-etching primer (SEP)를 차용하는 경우 접착제 종류와 타액의 존재 유무에 따른 전단결합강도의 차이에 관하여 비교 연구 하는 것이다. 소의 하악 영구 전치를 포매하여 만든 시편을 접착제의 종류에 따라 레진 접착제와 레진 강화형 글래스 아이오노머 접착제를 이용한 군으로 나누었고 각각 37% 인산으로 산부식 후 기존의 본딩용 프라이머를 사용하여 접착한 군과, SEP를 사용하여 접착한 군으로 분류하고, 타액 오염 유무에 따라 다시 각 군을 분류하여 전단결합 강도를 측정하였다. 그 결과 레진 접착제로 브라켓을 부착한 경우 SEP를 사용하여 접착한 군의 전단결합강도는 인산 처리군에 비해 낮은데 비해 레진 강화형 글래스 아이오노머를 사용한 경우, 전처리법에 따른 전단결합강도는 통계적으로 유의한 차가 없었으며, 접착제의 종류에 관계없이 타액 오염이 존재 시에는 SEP를 사용한 군이 인산처리군에 비해 높은 전단결합강도를 보였다. 이상의 결과에서 SEP를 사용 시 레진 접착제와 레진 강화형 글래스 아이오노머 접착제 모두 임상적으로 사용 가능한 전단결합강도를 보였으며, 특히 타액에 오염된 치면에서도 SEP를 사용하여 브라켓을 접착하는 것은 적절한 결합강도를 얻을 수 있으므로 임상적으로 유용할 것으로 생각된다.
Objective: To examine the prophylactic potential of 3 orthodontic bonding adhesives: Fuji Ortho SC, Illuminate, and Resilience. Methods: Thirty-six Wistar Wag rats were randomly divided into 4 groups consisting of 9 rats each. One of the groups received no treatment and was used as a control. In the other groups, individual bands coated with one of the 3 adhesives were cemented to the lower incisors. Enamel samples were obtained after 6 and 12 weeks and analyzed using scanning electron microscopy in combination with energy dispersive spectrometry. Results: Six weeks after band cementation, no fluoride was found in the enamel of the lower incisors. After 12 weeks, there was no fluoride in the enamel of teeth coated with the Resilience composite. However, in the case of the Illuminate composite and the resin-modified glass ionomer Fuji Ortho SC cement, the depth of fluoride penetration reached $2{\mu}m$ and $4.8-5.7{\mu}m$, respectively. Conclusions: Fluoride ions from orthodontic adhesives can be incorporated into the surface layer of the enamel. Orthodontists may apply orthodontic adhesives, such as the Fuji Ortho SC, to reduce the occurrence of caries during orthodontic treatment with fixed appliances.
이 연구는 시간 경과에 따라 폴리아크릴산 용액으로 표면 조건화된 법랑질에 대한 광중합형 글래스아이오노머 시멘트의 브라켓 전단결합강도를 인산용액으로 부식된 법랑질에 대한 치과 교정용 레진 접착제의 그것과 비교하여 브라켓을 접착할 때 상용되어 온 치과교정용 레진 접착제를 광중합형 글래스아이오노며 시멘트로 대체할 수 있는지의 여부를 구명하기 위하여 시행되었다. 발거된 사람 소구치의 법랑질 표면을 각각 10% 폴리 아크릴산용액과 38% 인산용액으로 처리한 후, 각각 시판되고 있는 광중합형 글래스아이오노머 시멘트의 일종(Fuji II LC)과 화학중합형 치과교정용레진접착제의 일종(Mono-Lok 2)으로 법랑질 표면에 금속브라켓을 접착하고, 시편을 실온에서 5분, 15분 방치한 후, $37^{\circ}C$의 증류수 속에 1일, 35일 동안 침지시킨 후, 브라켓 전단결합강도를 측정하고, 접착파절 패턴을 관찰하였다. 브라켓 접착5분과 15분 후의 광중합형 글래스아이오노머 시멘트의 브라켓 전단결합강도는 치과교정용 레진 접착제의 그것보다 유의성 있게 높았다. 광중합형 글래스아이오노머 시멘트와 치과 교정용 레진 접착제의 브라켓 전단결합강도는 브라켓 접착 1일 까지 증가하였으나 1일군과 35일군의 그것 사이에 통계적 유의차가 없었다. 이상의 결과는 광중합형 글래스아이오노머 시멘트가 브라켓 접착제로서 임상적인 유의성이 있음을 시사한다.
목적: 본 연구의 목적은 치열교정용 레진시멘트의 보관 조건이 치열교정용 브라켓의 접착강도에 미치는 영향을 보고자 함이다. 연구 재료 및 방법: 소의 하악 절치 순면 법랑질에 37% 인산으로 산 부식 후 치열교정용 레진시멘트인 Ortho Connect와 Orthomite를 3개월간 4℃ 냉장 보관 후 즉시 적용, 3개월간 4℃ 냉장 보관 후 24시간 동안 실온 보관하고 적용, 3개월간 24℃ 실온 보관 후 적용하는 세 조건에 따라 각 조건별로 15개의 하악 절치용 치열교정용 금속브라켓을 접착하고 광중합 한 뒤 24시간 후에 만능재료시험기로 전단접착강도를 측정하고 접착 실패 양상을 관찰하였다. 측정한 전단접착강도를 95% 유의수준에서 레진시멘트와 보관 조건에 대해 이원배치분산분석을, 레진시멘트에 보관 조건이 미치는 영향에 대해 일원배치분산분석을 했다. 결과: Ortho Connect는 냉장 보관 후 즉시 사용했을 때 가장 높은 전단접착강도를 보였으며 다른 조건 사이에는 차이가 없었다. Orthomite는 냉장 보관 후 즉시 사용했을 때 가장 낮은 전단접착강도를, 3개월 실온 보관했을 때 가장 높은 전단접착강도를 나타냈으며 이 두 조건 사이에만 유의한 차이가 있었다. 결론: Ortho Connect는 냉장 보관 후 즉시 사용해도 적절한 접착이 가능하지만, Orthomite는 냉장 보관을 한다면 충분한 실온 보관을 하는 것이 접착에 유리할 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.