• Title/Summary/Keyword: Orthodontic anchorage

Search Result 136, Processing Time 0.03 seconds

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Mode of tooth movement according to the timing of orthodontic force application after extraction (발치 후 교정력 적용 시기에 따른 치아 이동 양상)

  • Han, Sung-Ho;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.9-17
    • /
    • 2000
  • This study was performed to compare and analyze the mode of tooth movement according to the timing of orthodontic force application alter extraction. The upper right and left third incisors were carefully extracted at three-week interval in lout adult dogs. Both canines were used as an anchorage for the bodily movement of the upper second incisors. Orthodontic forte of 100 gm was simultaneously applied at one week after extraction on one side and four weeks after extraction on the other side using NiTi closed coil spring. While orthodontic force was applied for twelve weeks, the amount of tooth movement was measured at every second week with digital calipers. The animals were sacrificed at twelve weeks and histologic examination was executed to reveal any difference between both sides. The results were obtained as follows. 1. The tooth movement was likely to be faster in lout-week side 4han one-week side for the first two weeks while faster in one-week side during next two weeks 2. The rate of tooth movement was fastest during four to six weeks period, then decreased gradually. 3. The total amount of tooth movement was likely to be larger in one-week side compared to four-week side. 4. Any damage to tooth and periodontal tissue could not be seen in the histologic section of one-week side. These results suggest that earlier application of orthodontic force is better than later after extraction In terms of the rate of tooth movement.

  • PDF

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

Correction of dental Class III with posterior open bite by simple biomechanics using an anterior C-tube miniplate

  • Ahn, Hyo-Won;Chung, Kyu-Rhim;Kang, Suk-Man;Lin, Lu;Nelson, Gerald;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.270-278
    • /
    • 2012
  • In the correction of dental Class III molar relationship in skeletal Class II patients, uprighting of the mandibular posterior segments without opening the mandible is an important treatment objective. In the case reported herein, a C-tube miniplate fixed to the lower labial symphysis and connected with a nickel-titanium reverse-curved archwire provided effective uprighting of the lower molars, without the need of orthodontic appliances on the mandibular anteriors. Using this approach, an appropriate magnitude of force is exerted on the molars while avoiding any negative effect on the mandibular anteriors.

Scar formation and revision after the removal of orthodontic miniscrews

  • Choi, Yoon Jeong;Lee, Dong-Won;Kim, Kyung-Ho;Chung, Chooryung J.
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.146-150
    • /
    • 2015
  • Many clinicians expect complete healing after the removal of temporary anchorage devices, but clinical examination may reveal scar-like tissue. This report presents the typical features of scarring detected after the removal of miniscrews, and the clinical outcome of scar revision along with its pathologic features.

Comparison of the fatigue limit of fiber-reinforced composites and stainless steel wires when attached to the tooth surface for anchorage reinforcement (고정원 강화를 위해 치면에 부착한 fiber-reinforced composite과 스테인리스강 와이어의 피로한도 비교)

  • Kim, Moon-Jung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.302-311
    • /
    • 2005
  • This study was performed to compare the fatigue limit of stainless steel wires and Fiber-reinforced composites (FRC) under conditions of permitting physiologic tooth movement. and to evaluate the clinical value of FRCs which was used to reinforce the anchorage unit. The stainless steel wire groups were divided into round and rectangular wire groups. The FRC groups were divided into uni-directional and woven groups, with resin coating and without resin coating in the Proximal area After the number of cycles to failure of each of the 6 groups were measured within the $5{\times}10^5\;cycle$ fatigue limit simulating the orthodontic treatment period. the fatigue limit of each group was compared with each other The findings of this study were as follows. In stainless steel wires, the fatigue limit of rectangular wires were higher than that of round wires. But there was no statistically significant difference (p>0.05). In FRCs with resin coating and without resin coating in the interproximal area, the fatigue limit of uni-directional type was higher than that of the woven type (p<0.05). In uni-directional and woven type FRCs, the fatigue limit of FRC with resin coating in the interproximal area was higher thar that of FRC without resin coating (P<0.05) As the FRCs and stainless steel wires did not fracture until the $5{\times}10^5\;cycle$ fatigue limit which clinically is useful. it is sufficient to use FRC and stainless steel wire for reinforcing anchorage. When esthetics is important and the attachment of additional devices are necessary. it seems sufficient to use FRC as anchorage reinforcement.

Factors influencing the axes of anterior teeth during SWA on masse sliding retraction with orthodontic mini-implant anchorage: a finite element study (교정용 미니 임플랜트 고정원과 SWA on masse sliding retraction 시 전치부 치축 조절 요인에 관한 유한요소해석)

  • Jeong, Hye-Sim;Moon, Yoon-Shik;Cho, Young-Soo;Lim, Seung-Min;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.339-348
    • /
    • 2006
  • Objective: With development of the skeletal anchorage system, orthodontic mini-implant (OMI) assisted on masse sliding retraction has become part of general orthodontic treatment. But compared to the emphasis on successful anchorage preparation, the control of anterior teeth axis has not been emphasized enough. Methods: A 3-D finite element Base model of maxillary dental arch and a Lingual tipping model with lingually inclined anterior teeth were constructed. To evaluate factors influencing the axis of anterior teeth when OMI was used as anchorage, models were simulated with 2 mm or 5 mm retraction hooks and/or by the addition of 4 mm of compensating curve (CC) on the main archwire. The stress distribution on the roots and a 25000 times enlarged axis graph were evaluated. Results: Intrusive component of retraction force directed postero-superiorly from the 2 mm height hook did not reduce the lingual tipping of anterior teeth. When hook height was increased to 5 mm, lateral incisor showed crown-labial and root-lingual torque and uncontrolled tipping of the canine was increased.4 mm of CC added to the main archwire also induced crown-labial and root-lingual torque of the lateral incisor but uncontrolled tipping of the canine was decreased. Lingual tipping model showed very similar results compared with the Base model. Conclusion: The results of this study showed that height of the hook and compensating curve on the main archwire can influence the axis of anterior teeth. These data can be used as guidelines for clinical application.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Consideration of maxillary sinus bone thickness when installing miniscrews (미니스크류 식립 시 상악동의 골두께에 대한 고려)

  • Kim, Do-Hyun;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.354-361
    • /
    • 2009
  • Objective: Miniscrews are widely used in orthodontic treatment for the purpose of anchorage control. Maximum anchorage can be acquired by the use of miniscrews. Maxillary miniscrew has many clinical advantage for orthodontic treatment. Maxillary sinus, tooth root can be an obstacle for maxillary miniscrew installation. The purpose of this study was to find the safest area and direction of miniscrew insertion in consideration of the maxillary sinus. Methods: The maxillary sinus area of 40 patients (20 male, 20 female) was measured using 3D computed tomography and 3D reconstruction program. Results: The maxillary sinus floor was located most inferiorly between the 1st molar and 2nd molar and located most superiorly between the 1st premolar and 2nd premolar. Buccal bone thickness from the maxillary sinus is significantly thicker between the 1st molar and 2nd molar and significantly thinner between the 1st premolar and 2nd premolar. The area between the 1st premolar and 2nd premolar has a significantly longer vertical distance from CEJ to sinus in consideration of buccal bone thickness. Conclusions: Considering maxillary bone thickness, the posterior area has advantages over the anterior area for installing miniscrews safely and preventing perforation.

Miniscrew Installation Area and Condition on Maxillary Palatal Side (상악구개측 미니스크류 식립위치 및 조건)

  • Lee, Ki-Yeon;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.61-71
    • /
    • 2009
  • Anchorage control is important in orthodontic treatment. Recently miniscrew is widly used as maximum anchorage in orthodontic treatment, and then it is important to install miniscrew safely without damaging adjacent anatomic structure. In a view of Miniscrew's stability, maxilla is unfavorable than mandible, and moreover maxillary soft buccal bone has disadvantage on stability. so palatal area comes into notice for installation area. We measured distance between palatal roots and bone thickness at midpalatal area using 3D computed tomography, and have found following results. 1. On the comparison of distance between palatal roots, the distance between 2nd premolar and 1st molar was significantly longest and the distance between premolars was significantly shortest. 2. Going toward lateral area from midpalatal suture and posterior area from zero point, bone thickness significantly became shorter and shorter. And 5.0mm palatal sagittal plane has more significance decrease of bone thickness than 2.5mm palatal sagittal plane. According to these results, we can conclude that the palatal installation of miniscrew between 2nd premolar and 1st molar is safest. And it is more safe that comes closer to midpalatal suture and to anterior area in regard to incisive canal.