• 제목/요약/키워드: Orifice plate

검색결과 50건 처리시간 0.025초

Cavitation optimization of single-orifice plate using CFD method and neighborhood cultivation genetic algorithm

  • Zhang, Yu;Lai, Jiang;He, Chao;Yang, Shihao
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1835-1844
    • /
    • 2022
  • Single-orifice plate is wildly utilized in the piping system of the nuclear power plant to throttle and depressurize the fluid of the pipeline. The cavitation induced by the single-orifice plate may cause some serious vibration of the pipeline. This study aims to find the optimal designs of the single-orifice plates that may have weak cavitation possibilities. For this purpose, a new single-orifice plate with a convergent-flat-divergent hole was modeled, a multi-objective optimization method was proposed to optimize the shape of a single-orifice plate, while computational fluid dynamics method was adopted to obtain the fluid physical quantities. The reciprocal cavitation number and the developmental integral were treated as cavitation indexes (e.g., objectives for the optimization algorithm). Two non-dominant designs ultimately achieved illustrated obvious reduction in the cavitation indexes at a Reynolds number Re = 1 ×105 defined based on fluid velocity. Besides, the sensitivity analysis and temperature effects were also performed. The results indicated that the convergent angle of the single-orifice plate dominants the cavitation behavior globally. The optimal designs of single-orifice plates result in lower downstream jet areas and lower upstream pressure. For a constant Reynolds number, the higher temperature of liquid water, the easier it is to undergo cavitation. Whereas there is a diametric phenomenon for a constant fluid velocity. Moreover, the regression models were carried out to establish the mathematical relation between temperature and cavitation indexes.

오리피스 전단에 인접한 $90^{\circ}$엘보와 오리피스간의 거리가 유출계수에 미치는 영향 (The Effect of Distance between $90^{\circ}$Elbow close to Upstream Face of Orifice Plate and Orifice Plate on Discharge Coefficient)

  • 윤준용;성낙원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.357-360
    • /
    • 2002
  • The effect of distance between ninety degree elbow close to upstream face of orifice plate and orifice plate on discharge coefficient was investigated. The distributions of discharge coefficient and differential pressure caused by elbow and short upstream straight length were examined and modified discharge coefficient was introduced. The results presented in this study could be useful when orifice plate is installed under the condition of simple flow disturbance element and short upstream straight length.

  • PDF

Comparing geometric parameters of a hydrodynamic cavitation process treating pesticide effluent

  • Randhavane, Shrikant B.
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.318-323
    • /
    • 2019
  • Paper focuses on comparison between two different orifice plate configurations (plate number 1 and plate number 2) used as cavitating device in the hydrodynamic cavitation reactor for improving pollutant removal efficiencies. Effect of four different parameters such as hydraulic characteristics (in terms of range of flow rates, orifice velocities, cavitation number at different inlet pressures); cavitation number (in range of 5.76-0.35 for plate number 1 and 1.20-0.35 for plate number 2); inlet pressure (2-8 bars) and reaction time (0 to 60 min) in terms of chemical oxygen demand (COD) removal and chlorpyrifos degradation has been studied and compared. Optimum inlet pressure of 5 bars exists for degradation of pollutants for both the plates. It is found that geometry of orifice plate plays important role in removal efficiencies of pollutant. Results obtained confirmed that orifice plate 1 with configuration of 1.5 mm 17 holes; cavitational number of 1.54 performed better with around 60% COD and 98% chlorpyrifos removal as compared to orifice plate 2 having configuration of 2 mm single hole; cavitational number of 0.53 with 40% COD and 96% chlorpyrifos in 2 h duration time.

오리피스 유량계의 입구 속도 분포에 따른 유량 계측 왜곡 특성 (DISTORTION OF FLOW MEASUREMENT BY VARIOUS INLET VELOCITY PROFILE OF ORIFICE FLOWMETER)

  • 신병수;김남석;이상규;배용범;금오현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.596-600
    • /
    • 2011
  • In this numerical analysis, the distortion of flow measurement by inlet velocity profile of orifice flowmeter was investigated. To validate the numerical method, the convergence was monitored and the grid dependency was also checked. realizable k-e model was selected and y+ was about 50 in this calculation. the results shows that the pressure at the pressure tab near pipe wall was changed by inclined inlet velocity profile and it leads to distorted a measurement values of flow through the orifice plate from -3.8% to 9%. Therefore, the fully developed inlet flow was required for accurate flow measurement by orifice flowmeter. If not, the orifice plate installed at wrong location should be re-installed or additional actions should be taken.

  • PDF

원전 주급수 유량측정용 오리피스의 차압 비정상 고찰 (Investigation of Orifice delta pressure abnormal condition for measuring Main Feed Water Flow in Nuclear Power Plant)

  • 이우광;김계연;고우식
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.12-17
    • /
    • 2010
  • The orifice establishment which is improper does to change the entity differential pressure and occurs an error in flow measurement data. Because of this, the thermal power of nuclear power plant could be evaluated excessively and the safety margin could be decreased. In this paper, characters of orifice which is established abnormally was investigated. Specially, the orifice plate which is established in opposition case was modeled and analyzed. Finally, 14.4% was lowly measured differential pressure, when being established in the resultant opposition. And this result with EPRI and NRC experiences was similar.

멀티 오리피스를 이용한 에어스프링 동특성 개선에 관한 연구 (The Study on the improvement of dynamic characteristics with multi-orifice in airspring)

  • 김인수;황성호;한문성;고철수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.97-103
    • /
    • 2002
  • Vibration isolation technology using an air spring and laminated rubber bearing is widely used because it has excellent vibration isolation characteristics. In the part of that, we usually make use of the self-damped air suing. It is occupied two chambers, restrictor, diaphragm and load plate. Two chambers contain compressed air and the volume of chambers and the area of load plate give a definition of stiffness and load. The restrictor and the volume ratio of two chambers give a definition of damping ratio. The conventional model of restrictor is made of one orifice and it causes turbulent flow in the orifice at the region of large deflection. The stillness of air suing is larger and the damping is lower in the region of large deflection. In the multi-orifice case, the stiffness is similar to air spring with one orifice but damping ratio is larger than conventional air spring. And damping ratio is smaller than conventional air suing in small deflection region. Deflection is small in the region of high frequency so small damping is better than large damping. As a result, we can reduce the storage stiffness of air suing in the wide region of deflection and increase the damping ratio in the region of large deflection. After this, we will try to and the relation of Reynolds Number and Flow Resistance then we are going to make another restrictor for air spring to improve damping ratio and stiffness.

  • PDF

분체 이송관내 압력 조절을 위한 오리피스 주위에서의 입자 유동 및 마모 해석 (Particle Laden Flows Around Orifice Plates for Pressure Control in Pulverized Coal Pipe Lines)

  • 조형희;이재근;박호동;서태원
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1499-1508
    • /
    • 1998
  • A numerical study is performed to investigate pressure drops, particle trajectories and erosion around orifice plates in pulverized coal pipe lines. Particle impaction rates change significantly with orifice shapes and Stokes numbers. At Reynolds number of $5{\times}10^5$, the pulverized coal flows well with streamlines and do not collide at the orifice plates at small sizes (${\sim}20{\mu}m$). However, the large particles (over $70{\mu}m$) impact on the front face of the orifice and erode the orifice surface. The pressure loss coefficients around the erode orifice are largely different from the designed original orifice.

Orifice Inlet효과에 의한 이젝터 성능에 관한 수치해석적 연구 (Numerical Investigation of the Effects of an Orifice Inlet on the Performance of an Ejector)

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.318-322
    • /
    • 2009
  • Supersonic ejectors are simple mechanical components, which generally perform mixing and/or recompression of two fluid streams. Ejectors have found many applications in engineering. In aerospace engineering, they are used for altitude testing of a propulsion system by reducing the pressure of a test chamber. It is composed of three major sections: a vacuum test chamber, a propulsive nozzle, and a supersonic exhaust diffuser. This paper aims at the improvement of ejector-diffuser performance by focusing attention on reducing exhaust back flow into the test chamber, since alteration of the backflow or recirculation pattern appears as one of the potential means of significantly improving low supersonic ejector-diffuser performance. The simplest backflow-reduction device was an orifice plate at the duct inlet, which would pass the jet and entrained fluid but impede the movement of fluid upstream along the wall. Results clearly showed that the performance of ejector-diffuser system was improved for certain a range of system pressure ratios, where as there was no appreciable transition in the performance for lower pressure ratios and the orifice plate was detrimental to the ejector performance for higher pressure ratios. It is found that an appropriately sized orifice system should produce considerable improvement in the ejector-diffuser performance in the intended range of pressure ratios.

  • PDF

사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향 (Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods)

  • 정인기;박시우;고완욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

펌프 가압식 추진제 공급유로에서의 오리피스 개도에 따른 동적 수력특성 변화 (The Dynamic Characteristics of Pump-fed Hydraulics due to Different Diameter Ratios of the Plate Orifice)

  • 김형민;고태호;김상민;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.313-317
    • /
    • 2009
  • 액체추진제로켓엔진의 추진제 공급유로 내 압력보정을 목적으로 설치된 오리피스는 엔진의 시동 및 정지시, 압력파를 발생시키는 원인이 되며 압력파로 인한 저주파 불안정을 막기 위해서는 오리피스의 개도에 따른 동특성의 변화를 살펴볼 필요가 있다. 오리피스의 동특성 변화를 확인하기 위해 오리피스 공급 압력을 급격하게 증가하도록 하였고 오리피스의 개도를 바꿔가며 동적인 압력변화를 측정하였다. 오리피스의 개도가 증가함에 따라 오리피스에 의한 수격현상은 감소하였으며 오리피스 하류의 수력학적 영향이 지배적으로 나타나는 것을 확인하였다.

  • PDF