덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester)

  • 이승철
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.

덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (Optimal Location of Orifice in Duct Leakage Tester for Air Flow Measurement)

  • 이승철;박만흥;김광추
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2151-2156
    • /
    • 2004
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I and upstream distance to the fan in the rest cases(case $II{\sim}$), so as to determine the optimal location of the orifice and reduce the size of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of ${\pm}7.5%$ based on the real flow rate. The best outcome was achieved with the orifice located midway of the orifice duct 4 times its diameter long.

  • PDF

오리피스 유량계의 입구 속도 분포에 따른 유량 계측 왜곡 특성 (DISTORTION OF FLOW MEASUREMENT BY VARIOUS INLET VELOCITY PROFILE OF ORIFICE FLOWMETER)

  • 신병수;김남석;이상규;배용범;금오현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.596-600
    • /
    • 2011
  • In this numerical analysis, the distortion of flow measurement by inlet velocity profile of orifice flowmeter was investigated. To validate the numerical method, the convergence was monitored and the grid dependency was also checked. realizable k-e model was selected and y+ was about 50 in this calculation. the results shows that the pressure at the pressure tab near pipe wall was changed by inclined inlet velocity profile and it leads to distorted a measurement values of flow through the orifice plate from -3.8% to 9%. Therefore, the fully developed inlet flow was required for accurate flow measurement by orifice flowmeter. If not, the orifice plate installed at wrong location should be re-installed or additional actions should be taken.

  • PDF

이단 원추형 오리피스를 지나는 압력장과 유동장에 관한 수치적 연구 (Numerical Analysis for the Pressure and Flow Fields past a Two-Staged Conical Orifice)

  • 김연수;김유곤
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.278-287
    • /
    • 2002
  • The objective of the paper was to calculate the pressure drop and to investigate the recirculation region of the conical orifices used in Kwang-yang Iron & Steel Company. The flow field with water used as a working fluid was the turbulent flow for Reynolds number of 2$\times$10$^4$. The effective parameters fur the pressure drop and the recirculation region were the conical orifice\`s inclined angle ($\theta$) against the wall, the interval(S) between orifices, the relative angle of rotation($\alpha$) of the orifices, the shape of the orifice's hole(circle, rectangle, triangle) having the same area, the number(N) of the orifice's holes having the same mass flow rate, and the thickness(t) of the orifices. It was fecund that the shape of the orifice's hole, the number of the orifice's holes and the thickness of the orifice affected the total pressure drop a lot and that the conical orifice's inclined angle against the wall, the relative angle of rotation of the orifices, the number of the orifice's holes and the thickness of the orifices affected the center location of the recirculation region. The PISO algorithm with FLUENT code was employed to analyze the flow field.

오리피스 내부유동에 따른 like-doublet 인젝터의 분열 특성 (The Effects of Orifice Internal Flow on the Breakup Characteristics of Liquid Sheets Formed by Like-Doublet Injectors)

  • 정기훈;길태옥;윤영빈
    • 한국분무공학회지
    • /
    • 제7권4호
    • /
    • pp.32-41
    • /
    • 2002
  • The breakup characteristics of liquid sheets formed by like-doublet injector were investigated in the cold-flow and atmospheric ambient pressure condition. The sheet breakup wavelength, which induces the sheet to be broken into ligaments, as well as the sheet breakup length, which is important for the flame location, was measured using a stroboscopic light. The liquid ligaments are formed intermittently after the breakup of sheet, and the wavelength of ligaments has been believed to have a relation to the combustion instability of liquid rocket engine. Therefore, the wavelength of ligaments and the breakup length of ligaments into fine drops were also measured. Since these spray characteristics are affected by the flow characteristics of two liquid jets before they impinge on each other, we focused on the effects of orifice internal flow such as the cavitation phenomenon that occurs inside the sharp-edged orifice. From the experimental results, we found that the liquid jet turbulence delays the sheet breakup and makes shorter wavelengths for both sheets and ligaments. Since the turbulent strength of sharp-edged orifice is stronger than that of round-edged orifice, the shape of orifice entrance results in large differences in the spray characteristics. Using these results, we proposed empirical models on the spray characteristics of the like-doublet injector, and these models are believed to provide some useful and actual data for designing liquid rocket combustors.

  • PDF

고차압 제어 버터플라이 밸브의 오리피스 형상에 관한 연구 (A Study on the Orifice Shape of High-Differential Pressure Control Butterfly Valve)

  • 윤익상;진정인;류성기
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.107-114
    • /
    • 2021
  • Butterfly valves are used in various industries to control the flow rate, flow direction, pressure, and temperature. These are gaining popularity in the field of plant industry to enable high-differential pressure because of their low maintenance costs and ease of installation. This study presents a numerical analysis method to analyze changes in the flow characteristics of a high-differential pressure control butterfly valve based on the location and shape of the orifice. The numerical analysis was conducted using a commercial CFD program. The analysis results show a correlation between the orifice shape and cavitation phenomenon.

A cone-beam computed tomography study of the prevalence and location of the second mesiobuccal root canal in maxillary molars

  • Seong-Ju Lee ;Eun-Hye Lee ;Se-Hee Park ;Kyung-Mo Cho ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.46.1-46.8
    • /
    • 2020
  • Objectives: This study aimed to investigate the incidence and location of the second mesiobuccal root (MB2) canal in maxillary molars with the aid of various measuring points and lines using cone-beam computed tomography (CT). Materials and Methods: A total of 205 images of patients who underwent cone-beam CT examinations between 2011 and 2015 as part of their dental diagnosis and treatment were included. There were 76 images of the maxillary first molar and 135 images of the maxillary second molar. Canal orifices were detected at -1 mm from the top of the pulpal floor on cone-beam CT images. Image assessment was performed by 2 observers in reformatted image planes using software. Assessments included measurement of the distance between the MB1 and MB2 canals, and the angles between the lines connecting the MB1-MB2 and distobuccal (DB)-palatal (P) canals. The data were analyzed using the student's t-test. Results: The prevalence of the MB2 canal was 86.8% in the first molar and 28.9% in the second molar. The angle between the lines connecting the MB1-MB2 and DB-P canals was 2.3° ± 5.7° in the first molar and -3.95° ± 7.73° in the second molar. The distance between the MB1 and MB2 canals was 2.1 ± 0.44 mm in the first molar and 1.98 ± 0.42 mm in the second molar. Conclusions: The angles between the lines connecting the MB1-MB2 and DB-P canals was almost parallel. These findings may aid in the prediction of the location of the MB2 canal orifice.

Vortex Tube의 냉출구 Orifice에 관한 실험적 연구 (An experimental study for cold end orifice of vortex tube)

  • 유갑종;최병철
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1061-1073
    • /
    • 1996
  • Vortex tube is a simple device which splits a compressed gas stream into a cold stream and a hot stream without any chemical reactions. The phenomena of energy separation taking place in a vortex tube has been investigated experimentally. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner of special purpose. In this study, experimental study on vortex tube efficiency was performed with various cold end orifices and nozzles type. The experimental results indicate that there is an optimum diameter of cold end orifice and nozzle type for the best cooling performance. The variation of the maximum wall temperature along the vortex tube surface provides useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. The similarity relation for the prediction of the temperature of the cold exit air was obtained.

보스턴 테리어에서 발생한 음경골 이형성과 편측 잠복고환증을 가진 회음부 요도하열 (A Case of Perineal Hypospadias with Os Penis Deformity and Unilateral Cryptorchidism in a Boston Terrier)

  • 박우영;배춘식;김휘율;조기래;박우대
    • 한국임상수의학회지
    • /
    • 제26권2호
    • /
    • pp.185-188
    • /
    • 2009
  • 6개월령의 보스톤 테리어가 미측 음경 돌출과 불완전 형성된 포피, 이분화된 음낭, 잠복고환과 음경골 이형성을 나타내었다. 신체검사상, 요도구멍은 회음부 표면에 위치하였고 섬유성 띠는 귀두로부터 회음부에 있는 요도구멍까지 연결되어 있었다. 또한, 잘못 위치한 요도구멍을 통한 상행성 감염에 의하여 요도염을 나타내었다. 교정수술은 외부생식기 전체와 잠복고환을 절제하기 위하여 시행되었다. 포피, 음경 그리고 잠복고환은 성공적으로 절제되었다. 수술 후 요도구멍을 주기적으로 세척하고 항생제를 투여한 이후, 재발성 요도염은 사라졌다. 만약, 요도구멍의 위치가 재발성 요도염의 원인과 요실금의 주요 원인이 아니라면, 요도구멍을 재형성할 필요가 없는 이 치료법을 이용할 것을 제안한다.

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF