• Title/Summary/Keyword: Orifice Shape

Search Result 102, Processing Time 0.028 seconds

A successful Mustard operation for complete transposition of the great arteries combined with VSD, ASD, dextrocardia and PS: a report of one case (심실중격결손, 심방중격결손, 폐동맥협착과 우심증을 동반한 완전대혈관전위증의 치험)

  • 조중구
    • Journal of Chest Surgery
    • /
    • v.15 no.3
    • /
    • pp.346-354
    • /
    • 1982
  • A Complete transposition of the great arteries combined with V.S.D, A.S.D, dextrocardia, and P.S is a rare congenital anomaly. The patient was a 10 year-old female whose complaints were frequent URI, exertional dyspnea, and cyanosis at rest since birth. Cheat X-ray films showed Dextrocardia ; situs inversus, moderate cardiomegaly, and Characteristic egg-shape heart shadow. E.K.G, Echocardiography, Cardiac Catheterization, and Angio-Cardiography were performed. Open heart Surgery was done under diagnosis of d-TGA, Dextrocardia, V.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D. ($2.0{\times}2.0cm$. in diameter), V.S.D. type II ($1.5cm{\times}1.5cm$ in diameter), and pulmonary valvular stenosis were noted. Mustard operation using pericardial Baffle in the atrium for T.G.A. was perforsned. Teflon patch graft for closure of V.S.D. through tricuspid orifice and pulmonary Valvulotomy through pulmonary arteriotomy were performed. The post-op, low cardiac output Syndrome and dysrhythmicawere developed till Postoperative day #7, so that was controlled by inotropic and antiarrhythmic agents. After that, patient's conditions were Uneventful.

  • PDF

Spray Characteristics of Simplex Swirl Injector with Low Hydrodynamic Disturbance Generated by Pressure Fluctuation in Feed Line (축방향 압력섭동에 의해 발생되는 저주파 수력학적 교란이 단일 스월 인젝터에 미치는 영향 분석)

  • Khil, Tae-Ock;Kim, Sung-Hyuk;Kim, Hyeon-Sung;Yoon, Young-Bin
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2007
  • The low frequency combustion instability phenomena generated by pressure drop oscillation such as propellant shake in feed line are studied. To generate the flowrate oscillation by the pressure pulsation up to 400Hz without flow discontinuities and cavitations, a hydrodynamic mechanical pulsator of rotating disk type was produced. Injection pressure conditions are 5, 7 and 9 bar and pressure fluctuation frequency conditions are 0, 4, 6 and 8 Hz. When the injection pressure was oscillated by a mechanical pulsator, the spray shape was pulsated regularly. During the pulsated state of the spray with a mechanical pulsator, the spray characteristics, such as spray angle and liquid film thickness in orifice exit, were measured and compared with those in steady state without a mechanical pulsator. Though the mean injection pressure was fixed in the steady and fluctuating state, there were some differences in all measured values, i.e. liquid film thickness and spray cone angle, between both states.

  • PDF

Flow Analysis of Simulation Nuclear Fuel Loaded in the HANARO Flow Simulation Test Facility (하나로 유동모의 시험장치에 설치되는 모의 핵연료 유동해석)

  • Park Yong-Chul;Cho Yeong-Garp;Wu Jong-Sub
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.43-46
    • /
    • 2002
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is under 24 MWth of power operation since it reached to the initial critical in February, 1995. Many useful experiments should be safely performed to activate the utilization of the HANARO, but there is a radioactive risk of using the HANARO. To reduce the risk, a test facility, which is not reacted by nuclear fuel, is being developed to simulate similar flow characteristics with the HANARO. This paper describes the computational flow analysis to determine each shape of simulating fuels for simulating the flow similarities of 36 elements hexagonal fuels assembly and 18 elements circulating fuels assembly loaded in HANARO. The shares of orifices were determined by the trial and error method and the structural integrities of them were verified by the finite element method assuming that the flow rate and pressure differences of reactor core are constant. The analysis results will be verified with the results of the flow test to be performed after the installation of this test facility.

  • PDF

Hydrazine Doped Graphene and Its Stability

  • Song, MinHo;Shin, Somyeong;Kim, Taekwang;Du, Hyewon;Koo, Hyungjun;Kim, Nayoung;Lee, Eunkyu;Cho, Seungmin;Seo, Sunae
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.192-199
    • /
    • 2014
  • The electronic property of graphene was investigated by hydrazine treatment. Hydrazine ($N_2H_4$) highly increases electron concentrations and up-shifts Fermi level of graphene based on significant shift of Dirac point to the negative gate voltage. We have observed contact resistance and channel length dependent mobility of graphene in the back-gated device after hydrazine monohydrate treatment and continuously monitored electrical characteristics under Nitrogen or air exposure. The contact resistance increases with hydrazine-treated and subsequent Nitrogen-exposed devices and reduces down in successive Air-exposed device to the similar level of pristine one. The channel conductance curve as a function of gate voltage in hole conduction regime keeps analogous value and shape even after Nitrogen/Air exposure specially whereas, in electron conduction regime change rate of conductance along with the level of conductance with gate voltage are decreased. Hydrazine could be utilized as the highly effective donor without degradation of mobility but the stability issue to be solved for future application.

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Inkjet Printing of Small Droplets Using M-shaped Waveforms (M-shaped 파형을 이용한 작은 액적의 잉크젯 프린팅)

  • Hong, Songeun;Choi, Jiho;Kim, Gieun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.51-56
    • /
    • 2021
  • Using an inkjet printing process, we have investigated a droplet formation of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) near the orifice of a piezoelectric inkjet head. With an attempt to form the smallest droplet without any satellites, we have applied various waveforms such as the unipolar, bipolar, and M-shaped waveforms. It is found that the droplet velocity and volume vary depending sensitively on the waveform width and voltage. Of those, the M-shaped waveform is shown to provide the smallest droplet volume, followed by the bipolar and then unipolar waveforms. The droplet printed on a PET film roll by the M-shaped waveform has the diameter as small as 46.1 ㎛. It is likely that the second short unipolar in the M-shape waveform increases the droplet velocity gradient, rendering the droplet smaller.

Morphological analysis and morphometry of the occipital condyle and its relationship to the foramen magnum, jugular foramen, and hypoglossal canal: implications for craniovertebral junction surgery

  • Pakpoom Thintharua;Vilai Chentanez
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.61-68
    • /
    • 2023
  • Anatomical knowledge of the occipital condyle (OC) and its relationships to surrounding structures is important for avoiding injury during craniovertebral junction (CVJ) surgeries. This study was conducted to evaluate the morphology and morphometry of OC and its relationship to foramen magnum, jugular foramen (JF), and hypoglossal canal (HC). Morphometric parameters including length, width, height, and distances from the OC to surrounding structures were measured. The oval-like condyle was the most common OC shape, representing for 33.0% of all samples. The mean length, width and height of OC were 21.3±2.4, 10.5±1.4, and 7.4±1.1 mm, respectively. Moreover, OC was classified into three types based on its length. The most common OC length in both sexes was moderate length or type II (62.5%). The mean distance between anterior tips and posterior tips of OC to basion, and opisthion were 11.5±1.4, 39.1±3.3, 25.2±2.2, and 27.4±2.7 mm, respectively. The location of intracranial orifice of HC was commonly found related to middle 1/3 of OC in 45.0%. JF was related to the anterior 2/3 of OC in 81.0%, the anterior 1/3 of OC in 12.5%, and the entire OC length in 6.5%. These morphological analysis and morphometric data should be taken into consideration before performing surgical operation to avoid CVJ instability and neurovascular structure injury.

Effect of Pesticide Residues on Perilla Leaf by Nozzle Types of Knapsack Sprayers (배부식 분무기 노즐이 들깻잎의 농약잔류에 미치는 영향)

  • Son, Kyeong-Ae;Kang, Tae Kyeong;Park, Byeong Jun;Jin, Yong-Duk;Gil, Geun-Hwan;Kim, Chan Sub;Kim, Jin Bae;Im, Geon-Jae;Lee, Key-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.282-287
    • /
    • 2012
  • This study was carried out to clarify the effects of the application of pesticide by different spray nozzle types on pesticide residues. The average droplet size and discharge rate were investigated when the manual compressed sprayer with two head disk type nozzle and the knapsack engine powered sprayer with two head fan shape nozzles were used. The fan type nozzles were classified into three types by the number of orifice in the nozzle. Three type nozzles tested were fan with one orifice, fan with two orifices and fan with three orifices. Fan (trade name : D-3) with 2.4 L/min. of the discharge rate and $76{\mu}m$ of the average droplet size while maintaining constant pressure $1.1{\pm}0.2$ MPa, and fan D-35 with 2.6 L/min. and $90{\mu}m$ while maintaining constant pressure $1.0{\pm}0.2$ MPa were appropriate. The orifice size of D-3 was 0.65 mm length ${\times}$ 0.45 mm width and the orifice size of D-35 was 0.62 mm length ${\times}$ 0.46 mm width. The residue levels of imidacloprid on perilla leaves among four applications by four different nozzles show significantly difference with 5% significance level. The residue levels $3.76{\sim}3.92mg\;kg^{-1}$ by fan or disk type is smaller than $4.52{\sim}4.92mg\;kg^{-1}$ by fan II or fan III. The residue levels of imidacloprid on perilla leaf were different depend on the spray nozzles type.

EFFECT OF "STEP-DOWN" AND "BALANCED FORCE" PREPARATION METHODS ON THE SHAPE OF THE ROOT CANAL (Step-down과 Balanced force 근관성형술식에 의한 근관 형태의 변화)

  • Chin, Cheong-Hee;Kim, Jong-Hwa;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.768-779
    • /
    • 1995
  • This study was performed to investigate the effect of root canal shaping techniques on the change of the shape of prepared root canal. 40 mesiobuccal canals of recently extracted mandibular 1st and 2nd molars were divided into 4 groups and shaped by step-down/balanced force technique, step-down/step-back technique, step-back technique and conventional technique respectively. The change of the shape of root canal was traced by superimposing the radiographs obtained before and after shaping of each root canal. The results were as follows. 1. By the experimented techniques except conventional technique, the root canals were more shaped in convex side of apical area and in concave side of most curved and coronal area than in the other sides(P<0.05). By conventional technique, the root canals were more shaped in convex side than in convave side from apex to orifice(P<0.05). 2. By step-down/balanced force technique, the cancave sides at C and D points of proximal view and C point of clinical view were more shaped than the convex side(P<0.05). Through the entire canal, the concave side was more shaped than the convex side in proximal view(P<0.01). But there was no statistical difference between both sides in clinical view. 3. By step-down/step-back technique, the change of root canal shape was not statistically different in concave and convex sides at each point of both views(P>0.05). And through the entire canal in proximal view, there was no statistical difference in shaping percentage between both sides. But through the entire canal in clinical view, the concave side was more shaped than the convex side(P<0.1). 4. By step-back technique, the convex side at B point of clinical more shaped than the other sides(P<0.05). Through the entire canal in proximal and clinical views, there was no statistical difference in shaping percentage between both sides. 5. Comparing the total shaping percentage among techniques, that in conventional technique was the greatest numerically, and followed by the percentages in step-down/step-back, step-down/balanced force and step-back technique. But, in proximal view, shaping percentages were not statistically different among techniques(P>0.05, ANOVA test). In clinical view, shaping percentages in step-back and conventional techniques were statistically different(P<0.01, ANOVA test). * Proximal view: radiograph taken in mesiodistal direction. * Clincal view: radiograph taken in faciolingual direction. A point : 1mm point from radiographic apex B point : center point between A and C points C point : most curved point of root canal D point : center point between C point and canal oriffice.

  • PDF

Analysis of Discharge Characteristics for a Control Gate in a River (하도내 조절수문 방류특성 해석)

  • Son, Kwang Ik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.309-314
    • /
    • 2011
  • Analysis of discharge characteristics through control gates at river crossing structures is important for an effective water level control and water resources management. In recent years, many river control structures in four major rivers are under construction but only few researches on discharge characteristics at control gates could be found in Korea. The discharge characteristics depend on both shape of control gates and the effects of downstream water-depth. In this research, classification index for discharge patterns (free weir, submerged weir, free orifice, submerged orifice) through a control gate were reviewed with $h_g/h_1$, $h_3/h_g$, and $h_3/h_1$. Classification criteria of discharge patterns were also suggested. Representative discharge estimation equations for each discharge patterns were adopted and discharge coefficients were developed from a hydraulic model for a specific control gate which will be constructed in Nakdong river. Reliability of the derived discharge equation and coefficients were confirmed by comparisons between the real discharge in a model and the predicted discharge from the results of this research.