Flow Analysis of Simulation Nuclear Fuel Loaded in the HANARO Flow Simulation Test Facility

하나로 유동모의 시험장치에 설치되는 모의 핵연료 유동해석

  • Published : 2002.08.01

Abstract

The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is under 24 MWth of power operation since it reached to the initial critical in February, 1995. Many useful experiments should be safely performed to activate the utilization of the HANARO, but there is a radioactive risk of using the HANARO. To reduce the risk, a test facility, which is not reacted by nuclear fuel, is being developed to simulate similar flow characteristics with the HANARO. This paper describes the computational flow analysis to determine each shape of simulating fuels for simulating the flow similarities of 36 elements hexagonal fuels assembly and 18 elements circulating fuels assembly loaded in HANARO. The shares of orifices were determined by the trial and error method and the structural integrities of them were verified by the finite element method assuming that the flow rate and pressure differences of reactor core are constant. The analysis results will be verified with the results of the flow test to be performed after the installation of this test facility.

Keywords