• Title/Summary/Keyword: Organic removal

Search Result 1,935, Processing Time 0.028 seconds

Pollutant Removal Efficiency in Oxidation Pond with Filamentous Algae Mat (사상성 조류매트 산화지의 수질정화효율)

  • Choi, Sun-Hwa;Jang, Jeong-Ryeol;Ahn, Yeul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.655-660
    • /
    • 2005
  • This study was carried out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat(FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow. The removal efficiencies of COD, SS, T-N and T-P in Oxidation Pond with Filamentous Algae Mat were -2.5%, 84.7%, 63.9% and 89.2%, respectively. The removal efficiencies of T-N and T-P which are nutrients index were high. Results of this study would help us to determine the possibility of using the water treatment on the contaminated small rural streams.

  • PDF

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

Improvement of Ozone Process for Removal Rate Elevation of Humic Acid (부식산 제거율 향상을 위한 오존공정의 개선에 관한 연구)

  • Lee, Yu-Mi;Son, Yil-Ho;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.25-29
    • /
    • 2007
  • Ozone alone, Ozone/GAC, Ozone/$H_2O_2$ and Ozone/GAC/$H_2O_2$ processes were introduced for treatment of humic acid, which is a representative refractory organic compound. $H_2O_2$ and GAC used as catalysts for experiment. The treatment efficiencies of humic acid in each process were analyzed for pH variation, DOC removal, and $UV_{254}$ decrease. $UV_{254}$ decrease in Ozone/GAC and Ozone/GAC/$H_2O_2$ processes were the highest with about 93%, and Ozone alone and Ozone/$H_2O_2$ processes were 88%. DOC removal in Ozone/GAC/$H_2O_2$ process was the highest with 71%. Removal by Ozone/GAC, Ozone alone, and Ozone/$H_2O_2$ processes were 66%, 39%, and 47%, respectively.

  • PDF

Biological Removal Phosphorus Containing Swine Wastewater (생물학적 처리에 의한 돈사폐수의 인제거)

  • 신남철;박정호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.15-20
    • /
    • 2000
  • The studies of swine wastewater treatment aim to development of process using soil microorganism. Removal rate of swine wastewater containing organic matter was 99 percent in case of high loading rate. Microorganism was devoted to improve the treatment efficiency of the process. According to the result obtained from biological treatment of high loading rate swine wastewater. Hydraulic retention time was 2.3 days in unit process of biological phosphorus removal. BO $D_{rm}$ / $P_{rm}$ ratio was 1122 in room temperature anaerobic process and 355.6 in mesophilic anaerobic process. And then phosphorus removal rate mesophilic anaerobic process was 3 time as much as than room temperature acaerobic process.

  • PDF

A Study of Removal of Phenol by Peroxidase Extracted from Oenanthe javanica (Blume) DC (미나리 Peroxidase를 이용한 Phenol제거에 관한 연구)

  • 탁창준;최한영;신정식;나규환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.121-126
    • /
    • 1997
  • Peroxidase as one of the organic enzyme catalyst is useful for the oxidation treatment of various aromatic compounds such as phenols. The peroxidase content of Oenanthe javanica was 24.85 unit/g-fw in leaf, 5.74 unit/g-fw in stem, and 34.69 unit/g-fw in root respectively. The crude peroxidase extracted from Oenanthe javanka can be kept under low temperature (-70$\circ$C) condition for 6 months with the maximum 1% activity reduction. The optimum conditions of removal for 100 ppm phenol was pH 6, hydrogen peroxide 3.5 mM, peroxidase activity 8 unit/ml, temperature 20$\circ$C respectively. In the wide range of concentration from 50 ppm to 750 ppm phenol reveals average 54% removal rate under the same peroxidase activity (8 unit/ml) and different amount of hydrogen peroxide proportional to phenol concentration. Especially at the concentration of 100 ppm the maximum phenol removal rate was 72%.

  • PDF

Mixed matrix membranes for dye removal

  • Evrim Celik-Madenli;Dilara Kesiktas
    • Membrane and Water Treatment
    • /
    • v.14 no.4
    • /
    • pp.175-180
    • /
    • 2023
  • Mixed matrix membranes (MMMs) can be a promising alternative for the solution of dye removal from coloured effluents. Polymeric membranes are widely used due to their good film-forming ability, flexibility, separation properties, and cost. However, they have low mechanical, chemical, and thermal resistances. Moreover, the fouling of polymeric membranes is high because of their hydrophobic nature. Hence, there is an increasing interest in organic-inorganic hybrid membranes as a new-generation membrane material. It has been shown that carbon nanotubes have the potential to increase the material properties of polymers with their low density, high strength, hardness, and exceptional aspect ratio. In this work, carbon nanotubes blended MMMs were prepared and methyl orange removal efficiency of them was investigated. Compared to the bare membranes, MMMs showed not only increased hydrophilicity, water content, and pure water flux but also increased methyl orange rejection and flux recovery

The Study of High Strength Organic Wastewater Treatment by Movinig Media Complete Mixing Activated Sludge System (회전매체를 가진 완전혼합활성슬러지 공법을 이용한 고농도 유기성 폐수 처리에 관한 연구)

  • 김흥태
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.25-33
    • /
    • 1996
  • This study was conducted to Investigate the biological treatment capability of MMCMAS(Movinig Media Complete Mixing Activated Sludge) reactor for high strength organic wastewater (Average BOD=800mg/l). And this experimental results were compared previous study for low strength organic wastewater (Average HOD=150mg/l) by the same reactor. In this study, we abtained following conclusions ; (1) The laboratory MMCMAS reactor demonstrated that SBOD removal efficiencies of more than 90% can be achieved at organic Bonding rates of 30.9 gBOD/$m^2$/d for high strength organic wastewater and 39.4 gBOD/$m^2$/d for low strength organic wastewater, respectively. (2) The nitrification rates of MMCMAS reactor was found same results of similiar organic loading rates. (3) The ratio of attached biomass to total biomass on the moving media varied in the range of 40 to 63% and 32 to 94% for high and low strength organic wastewater, respectively. And it was varied at the various concentration of influents for the similiar organic loading rates. The sludge production rates was found approximately 0.37 gVSS/$gBOD_{rem}$. in MMCMAS reactor.

  • PDF

Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste (순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가)

  • Park, Seyong;Kim, Moonil;Park, Seonghyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.3
    • /
    • pp.5-16
    • /
    • 2021
  • In this study, the applicability of the MBR(Membrane Bio Reactor) process of oxygen dissolve was evaluated through comparison and evaluation of the efficiency of oxygen dissolve device and conventional aeration device in the explosive tank within the MBR process. The organic matter and ammonia oxidation by oxygen dissolve device were evaluated, and the efficiency of persaturation was evaluated by applying real waste water (anaerobic digester effluent treatement from food waste). SCOD and ammonia removal rates for oxygen dissolve device and conventional aeration device methods were similar. However, it was determined that the excess sludge treatment cost could be reduced as the yield of microorganisms by oxygen dissolve device is about 0.03 g MLSS-produced/g SCOD-removed lower than that of microorganisms by conventional aeration device. The removal rates of high concentrations of organic matter (4,000 mg/L) and ammonia (1,400 mg/L) in anaerobic digester effluent treatment from food waste were compared to the conventional aeration device and the oxygen dissolve device organic matter removal rate was approximately 13% higher than that of the conventional aeration device. In addition, for MLSS, the conventional aeration device was 0.3 times higher than for oxygen dissolve device. This is believed to be due to the high progress of sludge autooxidation because the dissolved oxygen is sufficiently maintained and supplied in the explosive tank for oxygen dissolve device. Therefore, it was determined that the use of oxygen dissolve device will be more economical than conventional aeration device as a way to treat wastewater containing high concentrations of organic matter.

Statistical Analysis of Sewage Plant Operation (하수처리장 운전조건의 통계분석)

  • 이찬형;문경숙
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • In this study, we examined statistical analysis between sewage plant operations parameters and effluent quality We got six components from principle component analysis of the operation parameters and secondary effluent quality. 91.8% of the total variance was explained by the six components. The components were identified in the following order : 1) organic matter removal by aeration basin microbe, 2) settleability on secondary clarifier load, 3) removal of nutrients, 4) microbial number increasement and species diversity, 5) microbial activity in aeration basin, 6) oxidation in aeration basin.

Removal of VOCs Using Nylon 6 fiber media Immobilized with Microorganisms (Nylon 6 fiber media를 이용한 Biofilter의 VOCS의 제거)

  • Kim, Jang-ho;Park, Dong-won;Kim, Hyoung-ho
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2003
  • Biofiltration was successfully applied to treat a mixture of volatile organic compounds(benzene, xylene) from contaminated air stream. Immobilized Ps. oleovorans biofilter was evaluated for its value in simultaneous removal of benzene and xylene from waste air stream. The variety of operating conditions were tested to evaluate important factors such as space velocity, pH, water content, etc.

  • PDF