P RELEASE AND UPTAKE ACCORDING TO INFLUENT ORGANIC LOADING IN BNR PROCESS

  • Kim, Kwang-Soo;Ahn, Chang-Hoon;Park, Jae-Kwang
    • Environmental Engineering Research
    • /
    • 제10권6호
    • /
    • pp.265-268
    • /
    • 2005
  • A batch-type study was conducted to investigate the phosphorus release and uptake under anaerobic and aerobic conditions according to organic loading changes. As organic loading increased, anaerobic P release increased but aerobic P uptake decreased. Where organic carbon contents remain high in aerobic conditions, PHB consumption within the microbial cells diminished, therefore it was found that in order to enhance P uptake rate, it should reach the endogenous growth stage where the entire organic loading was consumed.

유기물부하량 증가에 따른 음폐수 혐기성소화의 특성 분석 (Characteristics of Anaerobic Digestion using Food waste leachate under Increased Organic Loading rate)

  • 정재훈;정우진;장순웅;김진태;정성엽;양승연
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1127-1134
    • /
    • 2022
  • Herein , the effect of changes in the organic loading rate in anaerobic digestion was evaluated. The experiment was carried out by a laboratory -scale semi-continuous stirred tank reactor, and feedstock was food-waste leached. The organic loading rate was increased by 0.5 kgVS/m3 in each phase from 1.0 kgVS/m3 to 4.0 kgVS/m3. At the end of the operation, to check the failure of the reactor, the organic loading rate was increased by 1.0 kgVS/m3 in each phase and reached 6.0 kgVS/m3. This shows that the biogas yield decreased as organic loading rate increased. Biogas production seemed to be unstable at 3.5-6.0 kgVS/m3. Moreover, biogas production dramatically fell to approximately 0 mL at 6.0 kgVS/m3, which was decided as the operation failure on the 16th day of the las tphase. The result of the reactor analysis shows that the cumulation of volatile fatty acid increased as the organic loading rate increased. This seems to occur due to the decreasein pH in the reactor and led to extinction of anaerobic bacteria, which were the biogas products. Although the buffer compound (alkalinity) could prevent the decline in pH, the concentration of alkalinity was found to be lacking at a high organic loading rate

유기물부하에 따른 음식물찌꺼기의 산발효 특성 (Acid Fermentation Characteristic of Food Wastes According to the Organic Loading Rate)

  • 박진식;안철우;장성호
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.975-982
    • /
    • 2006
  • This study has been conducted to optimum operating conditions for effective acid fermentation according to OLR(organic loading rate) in the mesophilic and thermophilic acid fermentation process. The results are summarized as follows. In order to obtain reasonable acid fermentation efficiency in performing acid fermentation of food wastes in thermophilic condition, organic loading rate was required below 20 gVS/L.d. As $SCOD_{Cr}/TKN,\;SCOD_{Cr}/T-P$ of thermophilic acid fermented food wastes In organic loading rate 20 gVS/L.d were 18.9, 73.4 respectively, it was possible to utilize as external carbon source for denitrification in sewage treatment plant after solid-liquid separation as well as co-digestion of fermented food wastes and sewage sludge.

유기물 부하가 Anaerobic Hybrid Reactor 운전효율에 미치는 영향 (Effect of Organic Loading Rate on the Performance of Anaerobic Hybrid Reactor)

  • 신창하;오대양;김태훈;박주양
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.497-502
    • /
    • 2012
  • Anaerobic Digestion Process is evaluated as efficient wastewater treatment process with the removal of high concentrations of organic waste and production of biogas. This study was performed using hybrid anaerobic hybrid reactor (AHR) which consists of anaerobic sludge blanket (UASB) and biofilm-coated filter media was applied for Palm Oil Mill Effluent (POME) for 80 days to know optimum removal efficiency and production of biogas by comparing each part which divided changing Organic Loading Rate (OLR). As a result of this study, the removal efficiency was 90.4 % when the organic loading rate of influent was 15 kg COD/$m^3$/day. Since organic loading rate was up to 20 kg COD/$m^3$/day, the removal rate declined 80.7%. Over loading of influent caused sludge expansion and overproduction of microorganism. Amount of biogas was collected 82.3 L/day and pH was remained 6.9 constantly with balance of alkalinity.

호기성 고정생물막반응기에서 동일 질량부하의 수리학적 및 농도충격부하시 반응의 비교 (Comparison of Aerobic Fixed-film Process Response to Quantitative and Hydraulic Shock for the Same Increases in Mass Loading)

  • 안미경;이규훈;박태주
    • 한국환경과학회지
    • /
    • 제3권3호
    • /
    • pp.285-296
    • /
    • 1994
  • The objective of this study was to examine and compare to transient response to quantitative and hydraulic shocks which produce equal changes in mass rate of organic feed in aerobic fixed-film process. The general experimental approach was to operate the system at several growth rates under steady-state(pre-shock) conditions, then to apply step changes during day 3 in dilution rate(hydraulic shock) , or feed concentration(Quantitative shock) at the same organic mass loading rate. Performance was assessed in both the transient state and the new steady-state (post- shock). Shock load of different type did not produced equivalent disruptions of effluent quality for equal increases in mass loading rate. Based on effluent concentrations, a hydraulic and a Quantitative shock at the same mass loading caused equal increase in total effluent COD, but the increase was primarily a result of suspended solids the hydraulic shock and COD in the quantitative shock. The time which effluent COD came to peak values were about 32~48 hours at the low organic loads and 52 ~ 72 hours at the high organic loads, respectively A quantitative shock produced a much greater increase in effluent COD than did a hydraulic shock at the same mass loading. Mean and peak values of effluent concentration weve increased in 2.8~4.2 times at low organic loading rate, 5.2~6.6 times at the high organic loading rate, respectively. Key words : Aerobic fixed-film reactor, Quantitative shock, hydraulic shock, mass loading rate.

  • PDF

산업폐수처리를 위한 호기성 생물막 유동층 반응기의 연구(II) -유기물 충격 부하가 미생물 성장에 미치는 영향- (A Study on an Aerobic Fluidized-Bed Biofilm Reactor for Treating Industrial Wastewaters(II) -Effect of Organic Shock Loading Rate on Biomass Characteristics-)

  • 안갑환;박영식;최윤찬;김동석;송승구
    • 한국환경과학회지
    • /
    • 제2권4호
    • /
    • pp.325-330
    • /
    • 1993
  • A number of experiments were conducted in order to investigate the organic removal efficiency and biomass characteristics according to the organic shock loading rate in a fluidized bed biofilm reactor. At the operation conditions of HRT, 8.44 hour, superficial upflow velocity, 0.9 cm/sec and temperature, 22$\pm$$1^{\circ}C$, the removal efficiency of SCOD was founded to be 96.5, 92 and 90 % with the organic shock loading rate of 3.5, 10.8 and 33 kgCOD/m$^3$ㆍday, respectively. Within the F/M ratio ranged 0.4 to 2.0 kgCOD/kgVSSㆍday, the SCOD removal efficiency was shown as 90% at F/M ratio of 2.0 kgCOD/kgVSSㆍday, but the TCOD removal efficiency was 72 % at F/M ratio of 1.8 kgCOD/kgVSSㆍday. The average biomass concentrations were 7800, 14950 and 27532 mg/l on the organic shock loading rate of 3.5, 10.8 and 33 kgCOD/$\textrm{m}^3$ㆍday, respectively. This result was agreed with the fact that more biomass could be produced at high concentration of substrate, but some biomass was detached at the onset of shock and easily acclimated at the shock condition.

  • PDF

Effects of Organic Loading Rates on Treatment Performance in a Polyvinylidene Media Based Fixed-Film Bioreactor

  • Ahmed, Zubair;Oh, Sang-Eun;Kim, In S.
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.238-242
    • /
    • 2009
  • This study investigated the effects of organic loading rates on simultaneous carbon and nitrogen removal in an innovative fixed-film aerobic bioreactor. The fixed-film bioreactor (FFB) was composed of a two-compartment aeration tank, in which a synthetic filamentous carrier was submerged as biofilm support media, and a settling tank which polyvinylidene media (Saran) was used as settling aid for suspended solids. Three different organic loading rates, ranging from 0.92-2.02 kg chemical oxygen demand/$m^3$/day were applied by varying hydraulic retention time (HRT). The total soluble organic carbon removal efficiencies were in the range of 90-97%. The removal efficiency of ammonia was found to be in the range of 70-84%. Total nitrogen removal efficiency was found to be in the range of 40-45%, which indicates that denitrification reactions occurred simultaneously in the attached biofilm on the fibrous media in the aeration tank. The settling performance of suspended solids was significantly improved due to the presence of Saran media in the settling compartment, even for a short HRT. The fixed-film aerobic bioreactor used in this study demonstrated efficient treatment efficiency even at higher organic loading rates and at short HRTs.

식물플랑크톤의 세포외배출유기물을 고려한 소양호의 1차생산과 유기물 부하 (Organic Matter Sources in a Reservoir (Lake Soyang); Primary Production of Phytoplankton and DOC, and External Loading)

  • 남궁현;황길순;최광순;김철구;김범철
    • 생태와환경
    • /
    • 제34권3호통권95호
    • /
    • pp.166-174
    • /
    • 2001
  • 소양호로 유입되는 유기탄소량을 측정하였으며, 유기탄소 부하량에 대한 유기물 기원의 기여도를 계산하기위해서 내부생성유기탄소와 외부기원유기탄소를 측정하였다. 내부생성유기탄소는 EOC를 고려한 식물플랑크톤의 1차생산력으로부터 계산하였으며, 외부기원유기탄소는 유입수의 유기탄소 농도와 양어장의 유기탄소 배출량으로부터 구하였다. 1차생산력은 가두리 양식장이 설치된 1987견부터 증가하여 1995견가지 높은 분포를 보였으며 가두리가 철거된 1998년 이후 급격히 감소하였다. 내부생성유기탄소와 외부기원유기탄소의 부하는 여름철에 집중되었으며, 7${\sim}$9월에 연간 부하량의 43.2%와 71.7%가 각각 유입되었다. 1차생산력은 여름철에 $1,000\;mgC\;m^{-2}\;d^{-1}$ 이상으로 증가하였으며 겨울철에 비교적낮았다. 식물플랑크톤의 EOC배출율도 1차생산이 증가하여 수체의 DOC농도가 높은 여름철에 높았다. 전체조사기간동안 내부생성과 외부기원유기물의 평균적인 기여도는 각각 총부하량의 53.6%와 46.4%를 차지하였다. EOC 배출율은 1차생산력의 4.4${\sim}$21.2%를 차지하였으며, 1차생산력 산정에서 식물플랑크톤의 EOC 배출율이 고려되어야 할 것으로 보인다.

  • PDF

의암호 유역에서 발생하는 자체생산 유기물 저감방안에 관한 연구 (The Study on Decline Plan of Primary Production Organic Matter of Uiam Lake Basin)

  • 허인량;이건호;함광준;최지용;정의호
    • 한국환경보건학회지
    • /
    • 제30권1호
    • /
    • pp.50-58
    • /
    • 2004
  • The present study was designed to evaluate primary production organic matter in basin of lake around by execution of total maximum daily loading. BOD influent loading of Uiam lake was 2,819 kg/day, which was less then 28.3 percent, total effuluent loading as 3,619 kg/day, in comparision with BOD, total nitrogen influent loading was 4,681 kg/day, which was less then 10.0 percent, total effuluent loading as 5,150 kg/day. But in case of total phosphors influent loading was 73.3 kg/day, which was more then 34.2 percent, total run off loading as 48.3 kg/day. The result of survey reduction plan of primary production organic matter in basin of lake around which objectives of abstract is as follows. First plan was reduction of primary production organic matter by moving the outlet of municipal wastewater treatment center from present place to lake downstream. Secondary plan was improvement by diffusion type of outlet municipal wastewater treatment center. The third plan was reduction of environmental impact by passing and storing of municipal wastewater. Finally plan was decline water surface level which was present hydrouric retention time was reduction from 7.6 day to 6.0 day per meter.

Organic Matter and Hydraulic Loading Effects on Nitrification Performance in Fixed Film Biofilters with Different Filter Media

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • 제25권3호
    • /
    • pp.277-286
    • /
    • 2003
  • Nitrification performance of fixed film biofilters using coarse sand, loess bead, or styrofoam beads in biofilter columns 1 meter high and 30cm in diameter were studied at different hydraulic and organic matter loading rates. Synthetic wastewater was supplied to the culture tank in order to maintain desired TAN concentrations in inlet water to biofilters. All the biofilters were conditioned 5 months before start of sampling. TAN and $NO_2-N$ conversion rates increased with an increase in the hydraulic loading rate (HLR). However, the improvement in biofilter performance was not linearly correlated to HLR in styrofoam bead filters. This is mainly due to the characteristics of the styrofoam beads used. TAN conversion rates of sand filters increased with the increase of HLR up to $200m^3/m^2$. per day. No increase in the TAN conversion rate was observed at the highest HLR since flooding on the media surface took place. HLR had a significant impact on the TAN conversion rates in loess bead filter up to the highest HLR tested (P<0.05). TAN conversion rates were much less at organic matter loading rates of 9 and 18kg $O_2/m^3$ per day than those without the addition of organic matter in styrofoam bead filters. The addition of glucose resulted in a reduction of the TAN conversion rate from 540 to 284g $TAN/m^3$ per day. No significant difference of TAN conversion rates between the two organic matter loading rates was found (p<0.05). This indicates that the impact of organic matter on nitrification becomes less and less sensitive with an increase in the COD/TAN ratio. At an organic matter loading rate of 9kg $O_2/m^3$. per day, a great reduction of TAN conversion rates was observed in sand filters and loess bead filters. Clearly, organic matter can be one of the most Important Impacting factors on nitrification. $NO_2-N$ conversion rates showed a similar trend for TAN. Based on the TAN and nitrite conversion rates, styrofoam beads showed the best performance among the three filter media tested. Also, the low gravity and price of styrofoam beads make the handling easier and more cost-effective for commercial application. The results obtained at the highest organic matter loading rates can be used in the biofilter design in recirculating aquaculture system.