• 제목/요약/키워드: Organic hazardous air pollutants

검색결과 42건 처리시간 0.026초

울산 공단 대기에서 측정한 휘발성 유기화합물의 1997년과 1998년 결과 비교 (Comparison of the Concentration of Ambient Volatile Organic Compounds at an Ulsan Industrial Site in 1997 and 1998)

  • 나광삼;김용표;문길주
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.567-574
    • /
    • 1999
  • Volatile organic Compounds(VOC) were measured at an industrial site in Ulsan in 1997 and 1998. Twenty-four hour integrated ambient air samples were collected in 6 L SUMMA canisters during the periods of June 3 to 8, 1997 and June 12 to 17, 1998. The daily mean concentrations of the total $C_2-C_9$ VOC in 1998 were about one third of those in 1997. This decrease of VOC levels may be attributable to the measures to control the emissions of VOC and the decrease of the plant operation. The decrease in the concentrations of oxygenated hydrocarbons and alkenes, especially, contributed to the decrease of the total VOC concentrations in 1998. Lowever concentrations of alkenes compared to aromatics in 1998 were due to the decrease of ethylene and propylene. In the present study, methanol (12.0 ppb) was the most abundant species, followed by acetone (10.1 ppb), propane (6.0 ppb), and vinyl chloride (5.9 ppb). The total concentrations of hazardous air pollutants (HAPs) in 1998 were reduced compared to those in 1997. However, this decrease is due to the drastic decrease of the concentration of methanol. Except methanol, the concentrations of HAPs have not varied much. It is suspected that the VOC control strategy for the Ulsan industrial area has been successful for reducing the total VOC levels but might not be effective in reducing the concentrations of HAPs.

  • PDF

울산공단지역의 대기중 휘발성 유기화합물에 대한 인체 위해도 평가 (Health Risk Assessment of Airborne Volatile Organic Compounds in Ulsan Industrial Complex)

  • 이진홍;남병현;윤미정
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1999년도 춘계 학술논문발표회 논문집
    • /
    • pp.271-276
    • /
    • 1999
  • 미국을 비롯한 선진국들은 이미 휘발성 유기화합물(volatile organic compounds) 과 독성 중금속(toxic metals)을 비롯한 유해 대기오염물(hazardous air pollutants)에 대해 ATEOS (Airborne Toxic Element and Organic Species), TEAM(Total Exposure Assessment Measurement) 연구등의 대규모 연구를 통하여 인체에 미치는 영향이 가장 큰 물질군이 휘발성 유기화합물임을 밝혀낸 바 있다. (중략)

  • PDF

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

유해대기오염물질 중 14종의 휘발성유기화합물 1차 표준가스개발 (1 μmol/mol 수준) (Development of Primary Standard Gas Mixtures of Fourteen Volatile Organic Compounds in Hazardous Air Pollutants for Accurate Ambient Measurements in Korea (at 1 μmol/mol Levels))

  • 강지환;김용두;김미언;이진홍;이상일
    • 한국대기환경학회지
    • /
    • 제34권2호
    • /
    • pp.331-341
    • /
    • 2018
  • Hazardous air pollutants(HAPs) in the atmosphere are regulated as major air pollutants in Korea by the Air Pollution Control Act. In order to manage and control HAPs, accurate standards, which are traceable to the International System of Units(SI), are required. In this study, primary standard gas mixtures(PSMs) of volatile organic compounds(VOCs) which are specified as HAPs were developed at $1{\mu}mol/mol$ levels. The selected fourteen VOCs include Benzene, Toluene, Ethylbenzene, m-Xylene, Styrene, o-Xylene, Chloroform, 1,1,2-Trichloroethane, Trichloroethylene, Tetrachloroethylene, 1,1-Dichloroethane, Carbon tetrachloride, 1,3-Butadiene, and Dichloromethane. The HAPs PSMs were gravimetrically prepared in aluminum cylinders and their consistency was verified within the relative expanded uncertainty of 0.71% (k=2). Potential adsorption loss onto the internal surface of cylinders was estimated by cylinder-to-cylinder division method. No adsorption loss was observed within the uncerainty of 0.53%. The long-term stability of the HAPs PSMs was evaluated comparing with freshly prepared HAPs PSMs. The HAPs PSMs were stable for one year within the uncertainty of 0.38%. The final uncertainty of the PSMs was determined by combining the preparation uncertainty, verification uncertainty, and stability uncertainty. Finally, traceable and stable HAPs PSMs at $1{\mu}mol/mol$ levels were developed with the uncertainty of less than 0.76% in high-pressure aluminum cylinders.

LAEEM에 의한 전국 매립가스 발생량 추정에 대한 연구 (A Study on the Estimation of Landfill Gas Emission by LAEEM in KOREA)

  • 장영기;서정배
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.499-506
    • /
    • 1998
  • Recently almost wastes except recycled garbage are dumped into landfill site in Korea. Landfills are significant compounds (NMOCS) are produced. NMOCS include reactive volative organic compound (VOC) and hazardous air pollutants. LAEEM (Landfill Air Emissions Estimation Model) developed by Control Technology Center, V.S. EPA is used to estimate a mount of landfill gas from all landfills. As the result, landfill gas 4,121,000 ton, carbon dioxide 2,951,000 ton, methane 1,1120,000 ton are estimated as emissions from all landfills in Korea.

  • PDF

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF

Indoor exposure to hazardous air pollutants and volatile organic compounds in low-income houses in Lagos, Nigeria

  • Luqmon, Azeez;Musa, Olaogun;Mariam, Adeoye;Abdulazeez, Lawal;Babatunde, Agbaogun;Ibrahim, Abdulsalami;Adija, Majolagbe
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.277-288
    • /
    • 2012
  • This study investigated exposure to air pollutants in rooms in low-income houses at Shomolu (R1), Mafoluku (R2) and Mushin (R3) in Lagos state. The concentrations of most measured exceeded limits of Illinois Department of Public Health (IDPH) for indoor air quality. Air quality index (AQI) in rooms studied was unhealthy for sensitive people in terms of CO, unhealthy in terms of $SO_2$ and very unhealthy in terms of $NO_2$ while moderate air quality was obtained in terms of $PM_{10}$ in most rooms. High concentrations of carbontetrachloride, formaldehyde and xylene measured could have been responsible for some of the health complaints of the occupants. Factor analysis shows that cooking with kerosene, use of gasoline generator and insecticide were the major contributors to indoor air pollution in these rooms. Therefore, there is need to urgently tackle poverty as all affected by these pollutants were poor who live in substandard houses without kitchens.

SPME-GC를 이용한 유해 대기오염물질의 분석 (Analysis of Hazardous Organic Air Pollutants using SPME-GC)

  • 허귀석
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.229-230
    • /
    • 2001
  • 휘발성이 큰 많은 종류의 유기물질들이 대기오염물질로서 존재하고 있어 이에 대한 환경규제가 강화되고 있다. 이러한 유해 유기물질들은 ppb의 매우 낮은농도에서도 유해성을 갖고 있어 이를 분석하기 위한 공인된 분석방법은 모두 농축과정을 사용하고 있다. 캐니스터을 이용한 저온농축법과 흡착관을 이용한 농축법이 일반적으로 사용되고 있는데 이러한 농축방법은 고가의 농축장치를 필요로 하므로 이러한 유해물질의 측정이 보편화되는데 장애가 되고 있다. (중략)

  • PDF

실내공기질 모델을 이용한 신축공동주택의 VOCs 및 HCHO 배출량 추정 (Estimation of Source Emission Rate on Volatile Organic Compounds and Formaldehyde Using Indoor Air Quality Modeling in New Apartment)

  • 심상효;김윤신;양원호
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.929-933
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.

온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성 (The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity)

  • 서병량;김신도;박성규
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.