• Title/Summary/Keyword: Organic dust

Search Result 217, Processing Time 0.033 seconds

Effects of Fowl Dropping, Saw Dust and Rice Hull on Soil Microflora in vitro (실내배양에서 생계분, 톱밥 및 왕겨 첨가가 토양미생물상에 미치는 효과)

  • Yang, Chang-Sool;Kong, Hye-Suk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • This study was conducted to evaluate the effects of fowl dzopping. saw dust and rice hall on the soil microflora in vitro. The experiment was designed in seven treatments with the various organic materials and they were only soil (control). soil + fowl dropping (S+F), soil+fowl dropping+rice hull (S+F+R) soil+fowl dropping*saw dust (S+F+S). soil+chemical fertilizer (S+C.F), fowl dropping+rice hull (F+R) and fowl dropping+saw dust (F+S). All the samples of treatment were incubated in $28{\pm}2^{\circ}C$ condition and tested the activity of soil microflora for 84 days The activity of fungi, total bacteria, gram-negative bacteria and actinomycetes showed the highest values at, twenty-first day and the spore-forming bacteria was at forty-second day after incubation. The number of fungi and gram-negative bacteria showed the highest values in the treatment of F+S, the spore-forming bacteria and the actinomycetes were in the S+F+S. and the number of total bacteria was in the F+C.F., but in the treatment of F+R. all the microorganism except fungi showed the lowest values in their numbers. The composition ratio of dead bacteria was higher in the treatments of S+F+R and F+R than in those of others as 70% and 40% respectively. Actinomycetes isolated from the treatments of S+F and S+F+S were identified as Streptomyces sp.. Nocardia sp., Micromonospora sp. Actinomadura sp. and Saccharomonospora sp.

  • PDF

Explosion Properties and Thermal Stability of Reactive Organic Dust (반응성 유기물 분진의 폭발특성과 열안정성)

  • Han, Ou-Sup;Han, In-Soo;Choi, Yi-Rac;Lee, Keun-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.7-14
    • /
    • 2011
  • Using 20 L spherical explosion vessel and differential scanning calorimeter (DSC), an experimental investigation was carried on explosion characteristics and thermal decomposition of some reactive organic dust. As the result, the minimum explosion concentration of Benzoyl peroxide (BPO), Phthalic anhydride (PA) and 1-Hydroxybenzotriazol (HBT) exist between 10 and 15 g/$m^3$, which indicates that their explosion sensitivity are high. The maximum Kst values of HBT, PA and 97 % BPO are 251, 146 and 80 [$bar{\cdot}m/s$], respectively and the explosion severity of HBT is the explosion class of St-2. The flame velocity was also calculated from the combustion time of dust and flame arrival time to estimate the flame propagation characteristics in a closed vessel. The decomposition temperature and heat of decomposition reaction for 97 % BPO and HBT are $107^{\circ}C$ (1025 J/g), $214^{\circ}C$ (1666 J/g), respectively and it was found that these low decomposition temperature and high released heat affect the explosion characteristics.

Exploration of an Area with High Concentrations of Particulate Matter and Biomonitoring Survey of Volatile Organic Compounds among the Residents (부산 내 미세먼지 고농도 지역 탐색 및 체내 휘발성유기화합물 바이오모니터링 조사)

  • Hyunji Ju;Seungho Lee;Jae-Hee Min;Yong-Sik Hwang;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.344-352
    • /
    • 2023
  • Background: With its developed port and related industries, the concentration of fine dust is high in Busan compared to other cities in South Korea. Many studies have reported the health effects of fine dust, but there has been a lack of information regarding concentrations of volatile organic compounds among those who exposed to high levels of fine dust. Objectives: This study aimed to define an area with high concentrations of particulate matter and perform biomonitoring surveys among the residents of the area. Methods: Air quality data was collected and the mean level of each district in Busan was derived. We then defined the area with the highest concentrations of PM10 as a target site. Urine samples were collected from the 400 participants and analyzed for VOCs metabolites - trans,trans-Muconic Acid (t,t-MA) and N-AcetylS-(benzyl)-L-cysteine (BMA). Interviews were conducted by trained investigators to examine demographic information. The levels of t,t-MA and BMA were compared with representative South Korean population data (Korean National Environmental Health Survey). The association of the VOC metabolites and fine dust were analyzed by general linear regression analysis. Results: The mean of PM10 in the target site was 42.50 ㎍/m3 from 2018 to 2020. Among the 400 participants in the target site, 74.8% were female and the average age of the participants was 66 years. The geometric mean of t,t-MA was 71.15 ㎍/g creatinine and the BMA was 7.00 ㎍/g creatinine among the residents. The levels were higher than the geometric mean from the 4th KoNEHS. The levels of t,t-MA showed significance in BMI, smoking status, and household income. BMA showed significance in gender and age. Conclusions: Compared to the general population of South Korea, the target site's residents had higher biomonitoring levels. Based on this study, continuous screening for high risk areas, including the target site, and biomonitoring of the residents are required.

Agglomeration and Adsorption of Fine Carbonaceous Particles onto Asian Dust Particles. (황사입자에 의한 미세탄소 입자의 응집 및 흡착 현상)

  • 김경원;김영준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.341-342
    • /
    • 2002
  • 미세탄소입자는 원소탄소(elemental carbon)와 유기탄소(organic carbon)로 분류할 수 있다. 원소탄소는 불완전연소 과정에 발생하는 검댕(black soot), 원유의 정제과정에 발생하는 흑연(graphite), 자연상태에서 만들어진 다이아몬드의 3가지 형태로 존재한다. 이들 중 대기환경에 영향을 미치는 요소는 검댕입자로서 입경은 l$\mu\textrm{m}$이하이며, 일정한 형태를 지니고 있지 않다. (중략)

  • PDF

Measurement system of multi-components in indoor air quality (실내 공기의 다성분 측정시스템 개발에 관한 연구)

  • Kim, Bo-Whan;Lee, Jin-Ha;Kim, Tai-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.125-130
    • /
    • 2005
  • Six modules composed of individual sensors and circuit systems for oxygen, temperature, humidity, volatile organic compounds, dust, carbon dioxide, in the indoor air quality control were examined to see their individual performances. Experimental results showed that all the six modules were in good linearity with individual concentration variations

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this study, to optimize the production and utilization of biogas for organic waste resources, the precision monitoring of on-site facilities and the energy balance by facility were analyzed, and the solutions for field problems were investigated, and the design and operation guidelines for pretreatment facilities and generators were presented. Gas pre-treatment is required to solve frequent failures and efficiency degradation in operation of high quality refining facilities, and processing processes such as desulfurization, dehumidification, deoxidization, dust treatment, volatile organic compounds, etc. Since these processes are substances that are also eliminated from the high-quality process, quantitative guidelines are not presented in the gas pretreatment process, but are suggested to operate during the processing process as a qualitative guideline. In particular, dust, siloxane, and volatile organic compounds are the main cause of frequent failure of high-quality processes if they are not removed from the gas pretreatment process. Design of the biogas high-quality process. The operation guidelines provide quality standards [Methane content (including propane) of 95% or more] with 90% or more utilization of the total gas generation, two systems, and a margin of 10% or more. It also proposed installing gas equalization tank, installing thermal automatic control system for controlling equalization of auxiliary fuel, installing dehumidification device at the back of high quality for removing moisture generated in the process of gas compression, installing heat-resisting facilities to prevent freezing of facilities in winter and reducing efficiency, and installing membrane facilities in particular.

Pedological Characteristics of Asian Dust in Korea (한국에 강하한 황사의 토양학적 특성)

  • Zhang, Yong-Seon;Kim, Yoo-Hak;Sonn, Yeon-Kyu;Lee, Gye-Jun;Kim, Myung-Sook;Kim, Sun-Kwan;Weon, Hang-Yeon;Joa, Jae-Ho;Eom, Ki-Cheol;Kim, Sang-Hyo;Kwak, Han-Kang;Kim, Han-Myeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.6
    • /
    • pp.301-306
    • /
    • 2005
  • Asian dust was collected in Korea and soils in the arid area of northern China were analysed for its physical and chemical properties, and mineral compositions for in order to interpret the origin of Aeolian soils and estimate the effect of dust wind on the soil environment in Korea. Asian dust was collected at Suwon in Korea from 2002 to 2004. Soil samples were collected from the desert and Loess plateaus around Gobi desert in China. As a result of analysis of desert soil distributed on northern region and Loess soils in China, it was observed that soil pH was about 9, organic matter 11 to $23g\;kg^{-1}$, and CEC 7.1 to $18.4cmolc\;kg^{-1}$, showing a high spatial variation among different sampling locations. About 62 to 80% of particles were composed of quartz and feldspars, 2 to 14% calcite ($CaCO_3$) and dolomite [$Ca{\cdot}Mg(CO_3)_2$], and trace other clay minerals. All the dust particles in Korea were below 50 m in diameter, and the mineral compositions were quartz, mica, feldspar and some clay minerals. Major components of clay mineral of Asian dust was mainly illite as compared to the kaolin of soils in Korea. The base saturation of exchangeable Ca, Mg, K and Na in the Asian dust was above 250% due to the high content calcite. Most of upland soil in Suwon was thin and sharp type, but Asian dust in Korea was the spherical shape. Asian dusts in Suwon, Korea, did not show a definite mineralogical variation of the dust during the collection period. Difference between the Asian dust collected in Korea and the soils in arid area of China was observed in the physical and chemical properties, especially for particle size distribution, cations such as Ca, Mg, K and Na. However, some similarities were found on the mineral compositions and chemical properties between Asian dust collected in Korea and the loess of China.

Effects of Soil Organic Amendment as Plant Growing Media Component for Restoration of Planting Ground (식재기반 복원을 위한 유기질계 토양개량재의 효용성)

  • Ju, Jin-Hee;In, Da-Young;Kim, Won-Tae;Yoon, Young-Han;Choi, Eun-Young
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1363-1370
    • /
    • 2015
  • This study was aimed to determine effects of soil organic amendment as plant growing media component on restoration of planting ground. The changes of soil physical and chemical properties and germination and growth of kentucky bluegrass (Poa pratensis L.) were investigated. For treatments, soil was excavated at depth of 0-50 cm (referred as $S_1$) and at depth of 50-100 cm (referred as $S_2$). Then the half amount of $S_1$ soil was mixed with the soil organic amendment (coir dust 40% (v/v), bottom ash 25%, leaf mold 25%, vermiculite 5%, carbonized rice hull 5%) at a rate of 6% (v/v) (referred as $S_1CC$) and also the half amount of $S_2$ soil was mixed with the soil organic amendment at a rate of 6% (v/v) (referred as $S_2CC$) on pot in a 16 cm diameter and 14 cm height. The experiment was replicated 3 times with 3 pots per replication in randomized block design, and 100 seeds were planted per pot. In results, there was no significant difference in soil pH among the treatments with a slight decrease in soil hydraulic conductivity. However, in the $S_1CC$ treatment, positive increases in soil chemical properties, including electrical conductivity, organic matter, phosphoric acid, total nitrogen, exchangeable cation, and cation exchange capacity. Also, the germination rate, plant height, and number of leaves were higher in the $S_1CC$ treatment than those in other treatments. These results suggest that the addition of organic amendment to the soil at depth of 0-50 cm might be proper for restoring planting ground.

Health Hazardous Substances in Construction Work in Korea (건설업 근로자의 유해 작업 환경 노출 실태에 관한 연구)

  • Choi, Jae-Wook;Mun, Jung-Soo;Kim, Jeong-Ah;Won, Jeong-Il;Park, Hee-Chan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.74-92
    • /
    • 2000
  • This study was performed to evaluate the working conditions In construction workers through measurements of working environments and to improve the working conditions and to design the appropriate environmental and health management system. The results of measurement for working environments in construction work are as following: 1. The excess rate of noise and dust concentration in express highway construction, road construction, building construction and interior painting was 28.6% and 24.5% respectively. 2. The excess rate of mixed organic solvents concentration in interior painting was 39.3%. 3. The chain type bulldozer has the highest level of vibration; the excess rate was 85.7%, and among the vibration instruments, the level of left hand's vibration of all vibrators exceeded the criterion and in the case of drilling all the level of vibration exceeded the criterion in both hands. On the basis of the results in this research the environmental and health management system for construction workers must be considered. Therefore, it is necessary to be introduced the special medical examination and measurement of working environments in construction industry. In defining "the working place" of Article 39 of Enforcement regulations of industrial safety and health act, the word "indoors" should be deleted. Then the eligible industry for measurement of working environment must be extended. And it is also necessary for construction industry to be performed group health management service by agencies such as other manufacturing industry.

  • PDF

Concentrations of Air Pollutants Measured at Kosan during ACE-Asia Intensive Observation Period (ACE-Asia 집중관측기간에 제주고산에서 측정한 대기오염물질의 농도 분포특성)

  • ;;;;Jianzhen Yu;Keith Bower
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.487-501
    • /
    • 2002
  • The concentrations of gaseous (NO$_{x}$, SO$_2$, and $O_3$) and particulate (Elemental Carbon, EC and Organic Carbon, OC) pollutants were measured to evaluate the air quality of Kosan. Samples were taken at Kosan during ACE-Asia (Asian Pacific Regional Aerosol Characterization Experiment) IOP (Intensive Observation Period) (2001. 3. 21~2001. 5. 5). The mean concentrations of $O_3$(46.3$\pm$10.4 ppb) is higher than those at urban area such as Seoul and Busan in Korea. On the other hand, the mean concentrations of other gaseous species, NO$_{x}$(4.73$\pm$3.42 ppb) and SO$_2$(0.62$\pm$0.63 ppb) are lower than those at great cities. So we concluded that there are a few primary sources emitting atmospheric pollutants. The concentration of EC is higher and the concentration of OC is similar with or higher than those at other background sites. The recent EC concentration is higher than those measured before at Kosan. We concluded that there are more primary sources than other background sites and the amount of primary source have increased recently in Jeju. Backward trajectory and co..elation analysis were used to study where the air masses originated and distinguish the source of pollutants. While NO$_{x}$ and $O_3$ were mainly emitted and formed from Jeju inland area, concentrations of SO$_2$, OC and EC were affected by Asian Dust from China. Using the mean relative standard deviation of ozone, cleanness coefficient was obtained. The cleanness coefficient value, is 1.6 times larger than the value in 1992. Recently, the air quality of Kosan has been contaminated because of the Asian Dust events since spring and the rapid industrialization development.pment.