A Study on Aerobic Fluidized-Bed Biofilm Reactor for Treating Industrial Wastewaters(III) -Mathematical model for organic removal- (산업폐수처리를 위한 호기성 생물막 유동층 반응기의 연구(III) -유기물 제거에 관한 수학적 모델-)

  • 안갑환;박상준;송승구
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.331-336
    • /
    • 1993
  • A mathematical model for organic removal efficiency was investigated in a fluidized bed biofilm reactor by changing the feed flow rate, the residence time and the recycle flow rate. In batch experiment, organic removal could be assumed as first order and an intrinsic first order rate constant(k1) was found $6.4{\times}^{-6}cm^3/mg{\cdot}sec$ at influent COD range of 3040 - 6620 mg/L. In continuous experiment, at the condition of the influent COD, 3040 mg/L, the superficial upflow velocity, 0.47 cm/sec, the biofilm thickness 336 ${\mu}m$ and the biofilm dry density 0.091 g/mL, the calculated COD removal efficiency from the mathematical model gave 60% which was very close to the observed value of 66 %. As the feed flow rate was increased, the COD removal efficiency was sharply decreased and at constant feed flow rate, the COD removal efficiency was decreased also as the residence time being decreased.

  • PDF

Treatment of Fish Processing Wastewater Using Sequencing Batch Reactor (SBR) (연속회분식 반응기를 이용한 수산물 가공폐수 처리)

  • Paik, Byeong Cheon;Shin, Hang Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.18-26
    • /
    • 1994
  • This research investigated efficient operation mode for the successful performance of SBR(sequencing batch reactor) treating fish processing wastewater, and the effect of sodium chloride (NaCl) on treatment efficiency. 2-hour-annerobic, 6-hour-aerobic and 3-hour-anoxic operation during reaction period was found an effective operating method for organic and nitrogen removal from fish processing wastewater in SBR system. The average removal efficiencies of COD, BOD, and total nitrogen in SBR operated continuousely were 91%, 95%, and 67.1%, respectively. The estimated values of biomass yield coefficient(Y), microbial decay coefficient($K_d$), and bioreaction rate constant(K) were $0.35gMLSS/gCOD_{removed}$, $0.015day^{-1}$, and $0.209hr^{-1}$, respectively. As NaCl concentration increased from 5 to 30g/L, sludge settleability was cnhanced but organic removal in the reactor was decreased. NaCl of influent had considerable relationship with COD removal, whereas it did not significant affect nitrogen removal.

  • PDF

Characteristics of Hydrogen-sulfide(H2S) removal by a Biofilter with Organic Materials, Peat and Rock wool (유기담체인 Peat 및 Rock wool을 사용한 바이오필터에 의한 황화수소(H2S)의 제거특성)

  • Kim, Nam-jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.136-144
    • /
    • 2001
  • Two organic materials, peat and rock wool were used for removal of $H_2S$ by a biofilter inoculated with night soil sludge. By gradually increasing the inlet load of $H_2S$, the complete removal capacity, which was defined as the inlet load of $H_2S$ that was complete removed, and the maximum removal capacity of $H_2S$, which was the value when the removal capacity leveled off for organic materials, were estimated. Both values for Rock wool are larger than peat, based on a unit dry weight of material. By using kinetic analysis, the maximum removal rate of $H_2S$, $V_m$, and the saturation constant, $K_s$, were determined for all packing materials and the values of $V_m$ for rock wool was found to be larger. By using the kinetic parameters, the removal rates for $H_2S$ were compared both packing materials, and rock wool showed better performance for the removal of $H_2S$ in the inlet concentration range of 0~200ppm.

  • PDF

Desorption Characteristics of Volatile Organics Compounds in Soil by Microwave Heating (마이크로파 가열에 의한 토양 유기오염물질 탈착특성)

  • 문경환;김덕찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.65-73
    • /
    • 1996
  • The objective of this study is to investigate the removal efficiency of volitile organic compounds in soil, and the mechanism of desorption by bench scale microwave heating, Silt soil used for experiment and was impregnated with toluene, tetrachloroethylene, o-xylene and p-dichlorobenzene and the microwave treatment was conducted in a modified domestic microwave oven : 2450MHz, 700W. According to the results of the research the removal efficiency was improved with increasing water contents and the soil temperature appeared to plateau period extending to 2-3minutes corresponds to the temperature a which steam distillation was expected. The value of removal rate constant (k) were calculated on dry and moisty silt soil, respectively, which showed linear with increasing microwave heating time. Therefore, addition of a certain amount of water to the contaminated soil can efficiently enhance the ability of the soil to absorb microwave energy and promote the evaporation of the volitile contaminants.

  • PDF

Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization (반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율)

  • Jeong Byung-Gon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

Anaerobic Digestion of Pig Manure and Night Soil Mixed Waste in a Normal Temperature (I) (常溫에서 豚 . 人糞混合廢棄物의 嫌氣性處理(I))

  • Kim, Nam-Cheon;Min, Dal-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.63-71
    • /
    • 1988
  • This study is an experimental research on the anaerobic digestion of pig manure and night soil mixed waste at room temperature (25$\circ$C), and the results are shown below: 1. The steady-state condition based on gas production as digestion temperature dropped to 25$\circ$C from 35$\circ$C was achieved at around 28, 47, 56, 64 days respectively when its hydraulic retention time(HRT) are 10, 20, 30, 40 days. 2, Alkalinity and volatile acid(VA) was increased as increasing the organic loading. 3. Removal efficiency of chemical oxygen demand(COD) and biochemical oxygen demand (BOD) was improved as longer HRT, and generally COD value is lower and BOD value is higher relatively. 4. Overall treatment efficiencies of mixed waste are higher than of pig manure and of night soft. 5. Organic removal efficiency at room temperature (25$\circ$C) is 20-25% lower at medium temperature (35$\circ$C) in a same VS loading condition. 6. Refractory fraction of the infiuent VS and organic removal rate constant(K) estimated at around 37% and 0.107/day respectively.

  • PDF

Yarn dyed wastewater treatment using hybrid electrocoagulation-Fenton method in a continuous system: Technical and economical viewpoint

  • Gunawan, Denny;Kuswadi, Vincensius Billy;Sapei, Lanny;Riadi, Lieke
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.114-119
    • /
    • 2018
  • Yarn dyed wastewater has to be treated prior to disposal into the water bodies due to its high content of harmful organic compounds. In this study, the performance of Chemical Oxygen Demand (COD) removal and kinetic rate constant are investigated via hybrid electrocoagulation-Fenton in a continuous system using wastewater discharged from a yarn dyed industry in Surabaya city. The wastewater was treated in a batch mode using electrocoagulation to reduce Total Suspended Solid, followed by Fenton method in a continuous system to reduce COD level. Various Fe(II) feeding modes, molar ratio of $Fe(II)/H_2O_2$, initial pH of wastewater, and flow rate are used in this study. The results show that COD removal process obeys a pseudo-first order kinetics. At $Fe(II)/H_2O_2$ ratio of 1:10, initial wastewater pH of 3.0, and feed flow rate of 30 mL/min, the COD removal efficiency was observed to be 80%, and the kinetic rate constant is $0.07046min^{-1}$. The chemical cost for the treatment estimated to be IDR 160 per L wastewater, which is cheaper than the previously reported batch system of IDR 256/L.

광합성세균 미생물막반응기에 의한 유기성폐수의 처리특성

  • Oh, Kwang-Keun;Lee, Cheol-Woo;Jeon, Yeong-Joong;Lee, Jae-Heung
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.6
    • /
    • pp.738-742
    • /
    • 1996
  • An efficient packed-bed type biofilm reactor charged with immobilized phototrophs was developed to treat organic wastewater at an extremely high volumetric loading rate. The packed bed reactor (PBR) charged with porous ceramic beads was superior to a fluidized-bed reactor suspended with activated carbon powders in terms of many aspects such as BOD removal efficiency, operational stability, and overall economics. For wastewater with BOD concentration as high as 20, 000mg/l, the BOD removal efficiency was maintained above 90% when the hydraulic retention time (HRT) was longer than 1 day. The allowable volumetric BOD loading rate of this reactor (20gBOD/l day) is more than ten-folds higher than that of an ordinary activated sludge method. The behaviour of the reactor was represented well by a Monod type kinetic equation with a maximum specific BOD loading rate(P) of 22.2gBOD/l day and a half saturation constant(K$_{s}$) of 1, 750 mgBOD/l.

  • PDF

Kinetic modeling of organic and nitrogen removal from domestic wastewater in a down-flow hanging sponge bioreactor

  • Nga, Dinh Thi;Hiep, Nguyen Trung;Hung, Nguyen Tri Quang
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.243-250
    • /
    • 2020
  • A down-flow hanging sponge (DHS) bioreactor was operated for the treatment of domestic wastewater. The Stover-Kincannon model was applied for kinetic evaluation of the reactor performance during the operational period. As a result, the coefficient of determination (R2) for straight lines of effluent concentration from the experimental data and from the predictive data of BOD5; NH4+-N; and TN were 0.9727; 0.9883; and 0.9934, respectively. The calculation of saturation value constant (Umax - g L-1 d-1) and maximum utilization rate constant (KB - g L-1 d-1) were 56.818 and 75.034 for BOD5; 2.960 and 4.713 for NH4+-N; 2.810 and 8.37 for TN, respectively. The study suggests that Stover-Kincannon model can be used for effective evaluation of kinetic removal of BOD5; NH4+-N; and TN from domestic wastewater treated in a DHS bioreactor.