• 제목/요약/키워드: Organ Equivalent Dose

검색결과 30건 처리시간 0.023초

전립선암 영상유도방사선치료 시 pCT와 CBCT에 따른 치료계획별 체적선량의 변화 (Changes in Volume Dose by Treatment Plan According to pCT and CBCT in Image-guided Radiation Therapy for Prostate Cancer)

  • 원영진;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.209-214
    • /
    • 2018
  • The results of CBCT was obtained using image guided radiation therapy for radiation therapy in 5 prostate cancer patients. Using these results, we compared and evaluated the dose changes according to the treatment plan depending on the volume and position of bladder, rectum, and prostate. The 28 images of CBCT were acquired using On-Board Imaging device before radiotherapy. After the outline of bladder, rectum, and PTV, pCT images and CBCT images for radiotherapy were treated respectively. The volume of the bladder was increased by 105.6% and decreased by 45.2%. The volume of the rectum was increased by 30.5% and decreased by 20.3%. Prostate volume was increased by 6.3% and decreased by 12.3%. The mean dose of the rectum was higher in the CBCT than in the pCT, and V40 (equivalent to 40 Gy) of the bladder showed a reduction in all treatment regimens in the CBCT than in the pCT. Conformity treatment and homogeneity index of PTV showed better results in all treatment regimens using pCT than CBCT. It was found that the dose distribution of the pelvic internal organs varied greatly according to the patient 's condition and pretreatment.

토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석 (Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay)

  • 송주영;정재욱;윤미선;안성자;정웅기;나병식;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.178-183
    • /
    • 2011
  • 본 연구에서는 토모테라피를 이용한 폐종양의 방사선수술 치료계획을 수립한 후 기존의 선형가속기를 사용하였을 경우와 비교, 분석하여 선량분포 측면에서 유효성 및 타당성을 살펴보았다. 종양의 움직임이 5 mm 이하인 10명의 환자 CT 영상을 대상으로 기존의 선형가속기를 이용한 세기조절방사선수술에서와 동일한 처방선량과 동일한 조건의 중요장기 선량제한치로 토모테라피 치료계획을 수립한 후 선량분포를 비교하였다. 토모테라피를 이용한 결과에서도 기존의 선형가속기를 이용한 세기조절방사선수술과 동일하게 중요장기의 선량제한치를 충족시키면서 GTV에 처방선량을 부여할 수있음을 확인하였다. 방사선조사로 인한 폐의 정상조직합병증확률과 종양 반대편 폐의 등가균일선량 측면에서는 토모테라피가 기존 선형가속기보다 상대적으로 더 우수한 결과를 보였으나, 종양 내 치료선량 분포의 균일도에서는 기존 선형 가속기가 더 양호한 결과를 보였다. 치료 빔 전달 시간측면에서는 토모테라피가 기존 선형가속기 경우보다 2배 이상의 시간이 소요되었다. 이와 같은 본 연구의 결과 분석을 통해 폐종양 부위의 움직임이 적은 경우, 환자의 상태와 선량분포의 적합성 등을 고려한 최적의 치료계획을 세운다면 토모테라피를 사용하는 방사선 수술이 유효성 및 타당성이 있음을 확인할 수 있었다.

대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가 (Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor)

  • 김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.331-339
    • /
    • 2014
  • 현재 상용화되어 있는 양성자치료의 치료계획장비를 이용하여 방사선회전조사와 같은 치료계획을 양성자치료에 사용하여 대동맥 주위 림프절 종양에 대해 양성자회전치료와 양성자치료, 세기조절방사선치료를 이용하여 선량 평가를 하였다. 대동맥주위 림프절 종양 환자 9명을 대상으로 양성자회전치료, 양성자치료, 세기조절방사선치료의 방사선치료계획을 세워 각각의 선량 체적 히스토그램을 이용하여 선량 평가를 하였다. 양성자회전치료의 치료계획방법으로는 250~120까지 5도 간격으로 48개의 빔을 사용하였으며, 양성자치료와 세기조절방사선치료는 각각 2~3, 4~5개의 빔을 사용하였다. 모든 방사선 치료계획 시스템은 Eclipse planning system(Varian Medical system, Inc., Palo Alto, CA, USA)을 사용하였으며, 양성자회전치료는 아직 개발이 안된 치료장치이므로 치료계획방법에서 기계적, 물리적인 요소를 양성자치료계획과 동일하게 시행하였다. 선량분석방법으로는 정상장기(간, 신장, 소장, 위, 십이지장)와 종양의 선량 체적 히스토그램(dose-volume histogram: DVH)을 이용하여 생물학적 인자인 normal tissue complication probabilities(NTCP), organ equivalent dose(OED)와 mean dose를 각각의 치료계획방법을 비교 분석 평가하였다. 그 결과 양성자회전치료가 복부에 위치한 small bowel, duodenum, stomach의 볼륨 90%가 받는 선량에서의 결과는 다른 치료계획에 비해 높은 결과를 나타내고 있다. NTCP의 결과에서 양성자회전치료가 liver를 제외한 나머지 장기에서 가장 낮은 결과를 보여주고 있다. 하지만 복부에 위치한 정상장기에 받는 선량이 다른 치료계획에 비해 높아 치료계획 시 주위가 요하며, 물리적, 기계적인 요소는 양성자치료와 동일하다는 전제조건으로 양성자회전치료와 유사한 장비가 제작되어 상용화 되었을 때에 본 연구의 결과와는 다를 거라 사료된다. 현실적으로 아직 불가능한 치료방법이지만 앞으로 추가적인 양성자회전치료의 연구와 기술개발이 되어 상용화가 되면 기존의 특수방사선치료인 세기조절방사선치료, 양성자치료, 세기조절회전치료보다 효과적이고 안전한 치료방법이 될 거라고 사료된다.

전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량 (Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan)

  • 손혜경;이상훈;남소라;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.89-95
    • /
    • 2006
  • 본 연구의 목적은 다양한 전압 값과 전류 값에 따른 CT 투과 스캔 동안의 방사선 선량을 측정하고, 우리 기관에서 사용하는 임상 전신 PET/CT 환자 영상 획득 방식 중 감쇠 보정을 위해 사용하는 $^{137}Cs$ 투과 스캔과 환자의 진단용 고화질 CT 투과 스캔에 대한 방사선 선량을 평가하는 것이다. 방사선 선량 측정을 위해 Philips GEMINI 16 슬라이스 PET/CT시스템을 이용하였다. 다양한 튜브 전압 값과 시간에 따른 전류 값에 대해 표준 CTDI 머리 팬텀과 몸 팬텀을 이용하여 선량을 측정하였다. 이때 100 mm의 유효 길이를 가지는 펜슬 이온 전리함과 전기계를 선량 측정에 이용하였다. 측정은 공기 중, 팬텀의 중심, 그리고 팬텀의 가장 자리에서 각각 이루어졌다. 평균 흡수선량인 가중 CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) 값을 계산하고 이를 이용하여 등가 선량을 계산하였다. 본 연구자가 속한 기관에서의 전신 임상 PET/CT 영상 획득 방식을 이용한 투과 스캔에서의 방사선 선량 측정을 위해 Alderson 팬텀과 TLD를 이용하여 $^{137}Cs$ 투과 스캔과 고화질 CT투과 스캔을 각각 수행하여 각 인체 기관별 선량을 측정하였다. 측정에 사용한 TLD는 10 MeV X-선을 이용하여 교정한 후 ${\pm}5%$ 이내의 정확도를 가지는 것만 측정에 사용하였다. 장기 또는 조직은 ICRP 60을 참고로 선택하였다. 표준 CTDI 머리 팬텀과 몸 팬텀을 이용한 CT 투과 스캔에 대한 선량 측정 결과, 선량 값이 튜브 전압과 전류에 의존하는 것을 확인할 수 있었다. $^{137}Cs$ 투과 스캔과 고화질 CT 투과 스캔에 대한 유효 선량 측정 결과는 0.14 mSv와 29.49 mSv였다. PET/CT 시스템에서 표준 CTDI 팬텀과 이온 전리함, 그리고 Alderson 인체 팬텀과 TLD를 이용하여 투과 스캔에 대한 방사선 선량을 평가할 수 있었다. PET/CT 영상 획득 시, 우리가 원하는 영상의 화질을 유지하면서 환자에 대한 피폭을 최소화하기 위한 영상 획득 방식의 최적화가 추가적으로 이루어져야 할 것으로 생각한다.

  • PDF

쇄골 상부 림프절을 포함하는 왼쪽 유방암의 VMAT 치료계획시 X-Jaw split을 이용한 선량비교에 관한 연구 (Study on dose comparison using X-Jaw split in VMAT treatment planning for left breast cancer including supraclavicular lymph nodes.)

  • 김학준;이양훈;민제순
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.137-144
    • /
    • 2021
  • 목 적 : VMAT을 이용한 쇄골 상부 림프절을 포함하는 왼쪽 유방암 치료 시 X-Jaw를 나눈 치료계획과 기존 Full field VMAT 치료계획과의 선량분포를 비교 분석하여 X-Jaw split VMAT의 유용성을 평가하였다. 대상 및 방법 : 쇄골 상부 림프절을 포함하는 왼쪽 유방암 환자 10명을 대상으로 Vacuum cushion을 이용하여 CT simulation 하고 2 Arc Full field VMAT과 4 Arc X-Jaw split VMAT을 각각 치료계획 하였다. 각 치료계획은 처방 선량(Prescription dose)이 치료계획표적용적(Planning Target Volume, PTV)의 95% 이상 포함이 되고 주변 정상장기(Organ at risk, OAR)에 최소한으로 조사되도록 설계하였다. 이후 선량체적용적(Dose volume histogram, DVH)을 통해 PTV과 OAR의 대한 선량분석을 하였다. 결 과 : 10명의 환자의 Full field VMAT치료계획과 X-Jaw split VMAT치료계획의 데이터를 평균값으로 나타내어 비교하였다. 처방선량지수(conformity index, CI) 1.05±0.04, 1.04±0.03, 선량균질지수(homogeneity index, HI) 1.07±0.008, 1.07±0.009 로 두 치료계획 간 차이는 크지 않았다. OAR의 경우 왼쪽 폐의 V5 56.1±6.50%, 50.4±6.30%, V20 20.0±4.15%, 13.52±3.61% 로 Full field VMAT대비 X-Jaw split VMAT에서 V5이 10.0% V20은 32.6% 감소하였다. 심장의 V30은 3.68±1.85%, 2.23±1.52%, 평균 선량은 8.93±1.65 Gy, 7.67±1.52 Gy로 X-Jaw split VMAT에서 V30은 39.3%, 선량은 14.1% 감소하였다. 정상조직인 왼쪽 폐와 심장은 통계적 유의 수치인 p-value 0.05미만으로 나타났다. 결 론 : PTV의 체적이 크고 X Jaw의 길이가 15 cm 이상이 되는 쇄골 상부 림프절을 포함하는 왼쪽 유방암치료의 경우 X-Jaw split VMAT 치료계획은 기존의 치료계획과 동등한 HI와 CI로 유사한 PTV coverage를 유지 하면서 개선된 선량분포를 나타내 OAR인 폐와 심장 등의 방사선량을 줄일 수 있어 부작용을 줄이는데 효과적이라고 생각된다.

A 6-Week Oral Toxicity Study of Oral Cholera Vaccine in Sprague-Dawley Rats

  • Baek, Yeong-Ok;Choi, Seuk-Keun;Shin, Seo-Ho;Koo, Kyo-Hwan;Choi, Ho-Young;Cha, Seung-Bum;Li, Yong-Chun;Yoo, Hyeon-Jeong;Lee, Joo-Young;Kil, Ki-Hyun;Kim, Hak-Soo;Kang, Min-Soo;Kang, Boo-Hyun;Kim, Kap-Ho;Bae, Jin-Sook
    • Toxicological Research
    • /
    • 제28권4호
    • /
    • pp.225-233
    • /
    • 2012
  • The present study was carried out to examine the toxicity and target organs of oral cholera vaccine (OCV) after repeated oral administration in Sprague-Dawley rats for 6 weeks (3 administrations, once every 2 weeks). OCV is an inactivated oral cholera vaccine that contains Vibrio cholerae and confers protection against cholera caused by V. cholera serogroups O1 (Inaba and Ogawa serotypes) and O139 (strain 4260B). The animals were orally administered either OCV placebo (negative control) or OCV at a dose equivalent to 240 times the anticipated human dose. Throughout the administration period, no significant change was detected in clinical signs, body weight, food or water consumption, urinalysis results, hematological and clinical biochemistry test results, organ weights, necropsy, or histopathological examination results. Minor changes were found in hematological and clinical biochemistry tests; however, these changes were within normal ranges. The above results suggest that oral administration of OCV in rats did not induce any toxicologically meaningful changes, and the target organs could not be determined. This study was conducted in accordance with the guidelines established by Good Laboratory Practice (2009-183, KFDA, December 22, 2009) and the OECD Principles of Good Laboratory Practice (1997).

FOOD III 코드를 이용한 섭식경로 내부피폭 비교해석 (Comparative Analyses of the Internal Radiation Exposures due to Food Chain Pathway Using FOOD III Code)

  • 최용호;정규회;김진규;이정호
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.41-51
    • /
    • 1988
  • 우리나라의 환경특성에 적합한 섭식경로 내부피폭 해석코드를 확립하기 위한 준비과정으로서 FOOD III 코드를 부분적으로 보완하여 한국 성인 남자에 대한 선량평가 결과를 보완전의 결과와 비교하고 앞으로의 개선방안을 논의 하였다. 평가예제로는 1984년도 고리 원전 1호기에서의 Mn-54, Co-58, Co-60, I-131, I-132의 방출량 자료와 부지경계선상 대기확산인자(X/Q)의 최대값을 사용하였다. 보완된 코드로 계산한 결과, 장기별 선량은 보완 전에 비해 $20{\sim}70%$ 정도 낮아졌으며 예탁실효선량당량은 ICRP 제한치의 0.16%인 $7.935{\times}10^{-6}Sv/y$로 계산되어 보완전의 $1.32{\times}10^{-5}Sv/y$에 비해 40% 정도 낮게 평가되었다.

  • PDF

간암환자에 대한 세기조절방사선치료에서의 2차 산란선량평가 (Estimation of Secondary Scattered Dose from Intensity-modulated Radiotherapy for Liver Cancer Cases)

  • 김동욱;성지원;이현호;윤명근;정원규;배선현;신동오;정광주;임영경;신동호;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.295-302
    • /
    • 2013
  • 간암 환자에 대한 세기조절방사선치료(IMRT, intensity modulated radiotherapy) 및 세기조절회전방사선치료(VMAT, volumetric arc therapy)와 나선식토모치료(TOMO, Helical Tomotherapy)에서 2차 암의 원인이 될 수 있는 산란 및 누출선량률을 평가하였다. 5명의 간암 환자에 대해 IMRT와 VMAT, TOMO 치료계획을 실시하여 등중심(iso-center)으로부터 20, 40, 60, 80 cm 위치에서 유리선량계(RPLGD, radiophotoluminescence glass dosimeter)를 이용하여 선량을 측정하였다. 계획표적체적(Planning Target Volume, PTV)에 조사된 단위 선량(Gy)당 측정된 산란 및 누출선량은 IMRT의 경우, 최소 0.01에서 최대 3.13 Gy로 측정 되었고 VMAT에 대해서는 최소 0.03에서 최대 2.35 Gy까지, TOMO에 대해서는 최소 0.04에서 최대 1.30 Gy 까지 측정 되었다. 각 치료법에 대한 평균장기등가선량은 세기조절방사선치료에 대해 세기조절회전방사선 치료와 나선식단층토모치료가 각각 갑상선에서 75%와 51%, 대장에서 75%와 41%, 직장에서 72%와 48%, 전립선에서 76%와 50%로 나왔다. 본 측정을 통하여 산란 및 누출선량은 치료 중심으로부터의 거리에 따라 감소함을 보았으며 TOMO 치료의 경우, 환자치료를 위해 사용하는 모니터단위(MU, monitor unit)가 타 치료법에 비해 상대적으로 큼에도 불구하고 산란 및 누출선량은 크지 않는 것으로 평가되었다.

호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용 (Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode)

  • 김성기;임현실;김완선
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.29-35
    • /
    • 2014
  • 목 적 : 본 연구는 이미 상용화가 시작된 호흡 동조 체적 세기조절 회전 방사선 치료(Gated RapidArc) 이전의 자동화가 되지 않는 장비들에서 호흡 동조 방사선 치료(Gated radiation therapy)와 체적 세기조절 회전 방사선 치료(VMAT)를 동시에 시행할 수 있게 Gated RapidArc의 정확성을 분석하여 유용성을 평가하고, 진폭모드(Amplitude mode)를 이용하여 Gated RapidArc가 자동으로 되지 않는 장비에 환자를 적용하여 보고자 하였다. 대상 및 방법 : 방사선량 분포의 분석은 물 등가물질 고체 팬톰과 GafChromic 필름(EBT2 QD+, USA)을 이용하였으며, Film QA (ver. 2.2, USA) 필름 분석 프로그램을 이용하여 Gamma 인자(3%, 3 mm)를 분석하였다. 또한, 삼차원 선량 분포의 정확도를 확인하기 위해서 Matrixx(IBA Dosimery, Germany) 선량 측정 장비와 Compass(IBA Dosimetry, Germany) 선량 분석 프로그램을 이용하였다. 고체 팬톰을 이용한 호흡 동조 주기 신호는 4D 팬톰(Dynamic Thorax Phantom, CIRS, USA)과 Varian RPM(Real-Time Position Monitor) 호흡 동조 시스템을 이용하여 만들었으며, 자유호흡(free breathing)과 호흡정지(breath holding) 시에 따른 방사선량 분포를 각각에 대하여 분석 평가하였다. 환자에게 적용하기 위하여 2013년 2월부터 2013년 8월까지 간암환자 4명을 대상으로 4DCT의 영상을 얻기 위하여 충분한 호흡주기 연습후에 환자의 호흡주기에 맞게 위상모드(Phase mode)를 이용하여 환자가 고글의 호흡주기 패턴을 눈으로 보고 정확하게 따라할 수 있도록 하면서 4DCT의 영상을 획득하였다. Gated RapidArc 치료를 위하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 3회 호흡을 시행한 후 40%~60%의 구간에서 5~6초 호흡을 참을 수 있도록 연습을 하고, 치료 시 40%~60%의 구간에서 환자가 숨을 참을 때 Beam On 버튼을 눌러주는 방식의 반자동으로 치료를 시행하였다. 결 과 : 비 호흡 및 호흡 동조 체적 세기조절 회전 방사선 치료기법 간의 절대선량은 전산화 치료 계획을 이용한 계산값과 1% 이내의 차이를 보였으며, 치료 기법 간의 차이 또한 1% 이내의 차이를 보였다. Gamma 인자(3%, 3 mm)는 99% 이상의 일치함을 보였으며, 각 장기별 선량 차이는 대체로 95% 이상의 일치함을 보였다. 또한 호흡 동조 체적 세기조절 회전 방사선 치료를 위하여 만든 진폭모드(Amplitude mode)의 호흡주기와 실제 환자의 호흡주기가 잘 일치하는 것을 볼 수 있었다. 결 론 : 비 호흡 동조와 호흡 동조 시 체적 세기조절 회전 방사선 치료간의 절대 선량 및 방사선량의 분포가 매우 잘 일치함을 보였다. 이는 호흡 동조 체적 세기조절 회전 방사선 치료 기법을 이용하여 호흡에 따라 움직이는 흉부나 복부의 종양 치료에 적용이 가능한 것으로 사료된다. 또한 실제 치료환자를 대상으로 고글을 통하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 Gated RapidArc가 자동으로 되지 않는 장비에 치료를 적용한 결과, 5~6초정도 정지된 호흡에서 호흡 동조 체적 세기조절 회전 방사선 치료가 원활히 이루어짐을 알 수 있었다.

메토트렉세이트가 표면수식된 알부민미립구의 표적성 (Targetability of Surface-modified Albumin Microspheres with Methotrexate)

  • 황성주;조항범;이계주;김종국
    • Journal of Pharmaceutical Investigation
    • /
    • 제26권2호
    • /
    • pp.105-112
    • /
    • 1996
  • The surface of albumin microspheres was modified with methotrexate(MTX) by using 1,3-dicyclohexylcarbodiimide (DCC). Surface-modified albumin microspheres entrapping no MTX (SAMS), free MTX (SAMSF) and MTX-bovine serum albumin(BSA) conjugates(SAMSC) were prepared. The organ-targeting ability of free $[^3H]MTX,\;[^3H]MTX-BSA$ conjugate and the above microspheres was evaluated after i.v. administration of the preparations, equivalent to 150 nCi via the tail vein of mice. The total radioactivity in the lung increased immediately in a few minutes after i.v. injection of the microspheres, and then declined for the period of 3-4 weeks. However, the radioactivity in the liver, spleen and kidney increased slowly during the rapid decrease in radioactivity in the lung. This suggested that the microspheres could be entrapped rapidly in the lung through mechanical filtration because of their large size and slowly redistributed to the liver, spleen and kidney due to either the microspheres being degraded enough for the size to allow passage through the capillary beds of the lung and/or the release of $[^3H]MTX\;or\;[^3H]MTX-BSA$ conjugates from the microspheres. The amount of $60{sim}70%$ of the dose was targeted to the liver after the i.v. injection of SAMS, SAMSF and SAMSC, and the values of $(R_e\;^*\;_{e)liver}$ from the microspheres were $5{\sim}7$ compared to free MTX. This suggested that the liver-targeting ability from surface-modified albumin microspheres could be $5{\sim}7$ times as that of free MTX. The liver-targeted drug was accumulated in the Kupffer cells at the initial stage, thereafter the drug in the Kupffer cell was slowly transferred into the hepatocytes. The value of AUQ for liver from SAMS was higher than that from SAMSF, but much lower than that from SAMSC. This suggest that MTX bound to their surface could be eliminated slower than the entrapped free MTX, and faster than the entrapped MTX-BSA conjugates. This is consistent with the in vitro release rates order in the presence of a proteolytic enzyme. Also, surface-modified MTX was scarcely released in the absence of a proteolytic enzyme. Therefore, the surface-modified MTX nay be released (or eliminated) rapidly from SAMSC at the target site, and thereafter MTX may be released (or eliminated) slowly from the entrapped MTX-BSA conjugates in SAMSC for a long period.

  • PDF