• Title/Summary/Keyword: Organ/tissue dose

Search Result 108, Processing Time 0.026 seconds

Toxicity Study of Streptococcus pneumoniae Vaccine Administrated Subcutaneously in Rats

  • Park, Sin-Jeong;Seo, Kook-Heon;Han, Sang-In
    • Toxicological Research
    • /
    • v.27 no.2
    • /
    • pp.111-118
    • /
    • 2011
  • This study was performed to evaluate the toxicity of polysaccharide-based Streptococcus pneumoniae vaccine in Specific Pathogen Free (SPF), Sprague-Dawley (SD) rats. S. pneumoniae vaccine was administrated subcutaneously each dose level of high (560 ${\mu}g$/rat), medium (280 ${\mu}g$/rat) and low (140 ${\mu}g$/rat) on days 0, 14, 28. The rats were observed for 2 weeks or 4 weeks after the final injection. During this test, there were no significant dose-dependent changes in body weight, water and food consumption. In urinalysis and serum chemistry, dose-related changes were not detected. In hematology, the percent of neutrophils and lymphocytes in white blood cells were changed significantly. According to the measurement of organ weight, only spleen weight was significantly increased in all groups of administration compared to the control group. In the histopathological examination, an antigen-deposit, vacuolated macrophages, infiltrated inflammatory cells and a formation of granulation tissue were observed at the site of an administration. These results are considered as an outcome by immune responses through a vaccination. Consequently, the results of this study demonstrated that S. pneumoniae vaccine has no toxicity when it was administrated subcutaneously three times in 2-week interval at a high dose of 560 ${\mu}g$/rat.

The effect of adenosine triphosphate on propofol-induced myopathy in rats: a biochemical and histopathological evaluation

  • Erdem, Kezban Tuna Ozkaloglu;Bedir, Zehra;Ates, Irem;Kuyrukluyildiz, Ufuk;Coban, Taha Abdulkadir;Yazici, Gulce Naz;Arslan, Yusuf Kemal;Suleyman, Zeynep;Suleyman, Halis
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.1
    • /
    • pp.69-77
    • /
    • 2021
  • Propofol infusion syndrome characterized by rhabdomyolysis, metabolic acidosis, kidney, and heart failure has been reported in long-term propofol use for sedation. It has been reported that intracellular adenosine triphosphate (ATP) is reduced in rhabdomyolysis. The study aims to investigate the protective effect of ATP against possible skeletal muscle damage of propofol in albino Wistar male rats biochemically and histopathologically. PA-50 (n = 6) and PA-100 (n = 6) groups of animals was injected intraperitoneally to 4 mg/kg ATP. An equal volume (0.5 ml) of distilled water was administered intraperitoneally to the P-50, P-100, and HG groups. One hour after the administration of ATP and distilled water, 50 mg/kg propofol was injected intraperitoneally to the P-50 and PA-50 groups. This procedure was repeated once a day for 30 days. The dose of 100 mg/kg propofol was injected intraperitoneally to the P-100 and PA-100 groups. This procedure was performed three times with an interval of 1 days. Our experimental results showed that propofol increased serum CK, CK-MB, creatinine, BUN, TP I, ALT, AST levels, and muscle tissue MDA levels at 100 mg/kg compared to 50 mg/kg and decreased tGSH levels. At a dose of 100 mg/kg, propofol caused more severe histopathological damage compared to 50 mg/kg. It was found that ATP prevented propofol-induced muscle damage and organ dysfunction at a dose of 50 mg/kg at a higher level compared to 100 mg/kg. ATP may be useful in the treatment of propofol-induced rhabdomyolysis and multiple organ damage.

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Inhibitory Effects of Deer Antler Herbal-Acupuncture Solution on Cathepsin S and L Activity in RA Model Mice

  • Ahn, Hyung-Jun;Yoon, Jong-Hwa;Kim, Kyung-Ho;Lee, Seung-Deok;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.22 no.2
    • /
    • pp.71-81
    • /
    • 2005
  • Objective : Dear antler (Cervus korean TEMMINCK var. mantchuricus Swinhoe) used for traditional immunosuppressive and immuno-activating action. The effect of deer antler herbal-acupuncture(DAH) solution, prepared by water extract method, on cathepsin activities in bone tissues (cartilage and synovial) cells from mouse rheumatoid arthritis (RA) model was studied. The cysteine endoprotease cathepsin mediates degradation of the MHC class II invariant chain (Ii) in human and mouse antigen-presenting cells. The studies described here examine the functional significance of cathepsin inhibition on autoantigen presentation and organ-specific autoimmune diseases in a murine model for RA. Methods : An animal model for RA in BALB/c mice thymectomized 3 days after birth (3d-Tx) was constructed All 3d-Tx BALB/c mice developed autoimmune lesions in the bone tissue cells, starting at 3 weeks of age, and the disease mediated by CD4+ T cells was chronic and progressive. Significant inhibitory effects of DAH solution on cathepsin S and L were observed in each organ in a dose-dependent manner. Moreover, we confirmed that cathepsin S and L activity in each organ were clearly inhibited by DAB solution. When we examined the inhibitory effects of DAH solution against autoantigen-specific T cell responses in vitro, in regional lymph node cells, but not in spleens, from model mice, a significant inhibitory effect of DAB solution was observed in a dose-dependent manner. DAH solution do not block T cell proliferation to Con A, indicated that the dose of DAB solution 10 to $20\;{\mu}g/m{\ell}$ was sufficient to inactivate the autoantigen-specific T cell responses in vitro. In vivo therapeutic effects of DAB solution were examined in a murine model for RA, autoantigen-specific (C-II-specific) T cell response were significantly inhibited in LNCs from DAH solution-treated mice. Results : Iinhibition of cathepsin S and L in vivo alters autoantigen presentation and development of organ-specific autoimmunity in RA model. Conclusion : These data identify selective inhibition of cysteine protease cathepsin S and L as a potential therapeutic strategy for autoimmune disease process such RA. Thus, DAH solution will served as a potent anti-inflammatory and anti-arthritic agents for treatment of human RA.

  • PDF

The Effects of Regular Injection of High Dose Vitamin C on Liver Damage in Paraquat Poisoned Rat Model - Prehospital Care Model - (백서의 paraquat 중독모델에서 고용량 Vitamin C의 주기적 투여가 간에 미치는 영향 병원전 처치 모델)

  • Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.10 no.1
    • /
    • pp.51-60
    • /
    • 2006
  • Background: The toxicity of paraquat has been known to be caused by oxygen free radicals which leads to the lipid peroxidation and multiple organ failure. High dose vitamin C has been known to be a effective antioxidant activities against the paraquat intoxication. This study was designed to evaluate the effect of regular injection of high dose vitamin C on liver damage in paraquat poisoned rat model. Method: Fifty five rats of Sprague-Dawley strain were divided into three groups: control group, only intraperitoneally injected saline; paraquat group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected saline; paraquat and vitamin C group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected vitamin C(72 mg/kg). Rats were sacrificed on the 12 hours, 1st day, 2nd day, 4th day, 7th day after injection and liver tissue was obtained. H&E(Hematoxylin & Eosin) stain and Masson's trichrome stain for collagen fiber detection were undertaken. The results were observed using the microscope. Results: 1. There were no differences between control and experimental group at the 12hours after regular injection of high dose vitamin C. 2. There were significantly decreased liver damage in experimental group in the 1st day after regular injection of high dose vitamin C. 3. There were significantly increased recovery of liver damage with time in experimental group after regular injection of high dose vitamin C. Conclusion: These results suggest that regular injection of high dose vitamin C is effective in decreasing liver damage in paraquat intoxication.

  • PDF

Dosimetric Impact of Ti Mesh on Proton Beam Therapy

  • Cho, Shinhaeng;Goh, Youngmoon;Kim, Chankyu;Kim, Haksoo;Jeong, Jong Hwi;Lim, Young Kyung;Lee, Se Byeong;Shin, Dongho
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.144-148
    • /
    • 2017
  • When a high density metallic implant is placed in the path of the proton beam, spatial heterogeneity can be caused due to artifacts in three dimensional (3D) computed tomography (CT) scans. These artifacts result in range uncertainty in dose calculation in treatment planning system (TPS). And this uncertainty may cause significant underdosing to the target volume or overdosing to normal tissue beyond the target. In clinical cases, metal implants must be placed in the beam path in order to preserve organ at risk (OARs) and increase target coverage for tumors. So we should introduce Ti-mesh. In this paper, we measured the lateral dose profile for proton beam using an EBT3 film to confirm dosimetric impact of Ti-mesh when the Ti-mesh plate was placed in the proton beam pathway. The effect of Ti-mesh on the proton beam was investigated by comparing the lateral dose profile calculated from TPS with the film-measured value under the same conditions.

Dosimetric Comparison of Radiation Treatment Techniques for Breast Cancer : 3D-CRT, IMRT and VMAT (유방암 방사선치료 기법에 따른 선량 비교 : 3차원 입체조형치료, 세기 변조 방사선치료, 입체세기조절회전 방사선치료)

  • Lee, Bo-Ram;Lee, Sun-Young;Yoon, Myong-Geun
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.237-244
    • /
    • 2013
  • The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OED(Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ~ 2.02 Gy, 0.36 ~ 5.01 Gy, 0.25 ~ 2.49 Gy, 0.14 ~ 6.92 Gy, 0.03 ~ 2.02 Gy, 0.01 ~ 1.06 Gy, 0.25 ~ 6.08 Gy, 0.08 ~ 0.59 Gy, 0.01 ~ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

Determination of Growth Performance, Viscera Organ Weights and Ileal Intestinal Architecture of Broilers in Response to Drinking Water Added Extractions from Wooden Chips for the Starter Period

  • Macelline, Shemil Priyan;Wickramasuriya, Samiru Sudharaka;Shin, Taeg Kyun;Kim, Eunjoo;Cho, Hyun Min;Hong, Jun Seon;Nam, Jeong Bin;Yang, Seung Min;Oh, Geun Hye;Kang, Seog Goo;Heo, Jung Min
    • Korean Journal of Poultry Science
    • /
    • v.45 no.3
    • /
    • pp.147-154
    • /
    • 2018
  • A total of 90 one-day-old male broilers (Ross 308) were randomly assigned to one of the three dietary treatments, each consisting of six replicates (5 broilers/cage). The dietary treatments were 1) control (CON: fresh clean water with no supplement); 2) low dose [LD: CON + 1.56% extractions from the wooden chips (EWC)] and 3) high dose (HD: CON + 12.5% EWC). Drinking water supplemented with EWC was provided using specifically designed individual nipple drinker units. Average daily water intake (ADWI), average daily gain (ADG), average daily feed intake (ADFI), and feed conversion ratio (FCR) were measured weekly for 21 days. One broiler from each cage was euthanized for measuring the visceral organ weights and collecting ileal tissue samples for ileal architecture analysis on day 21. Broilers assigned to the LD and HD watery groups showed higher ADWI than that in broilers consumed CON on day 7 (P<0.05). The broilers subjected to HD treatment showed a deeper crypt depth (P<0.05) than that in broilers subjected to LD and CON on day 21. Therefore, broilers consumed HD showed a lower (P<0.05) villus height:crypt depth ratio than that broilers consumed CON on day 21. Broilers provided drinking water containing any of the tested concentrations of EWC showed no effect (P > 0.05) on growth performance, ileal villus height, and visceral organ weights as compared with those in the CON from hatch to 21 days. In conclusion, broilers fed HD showed reduction in villus height:crypt depth ratio without impairing growth performance and visceral organ weights for the experimental period.

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF