• Title/Summary/Keyword: Order-specific equipment

Search Result 142, Processing Time 0.028 seconds

Study on the Treatment, Utilization and Control of the Acid Mine Drainage for Colliery - An on-site test on the Applicability of a Korean-type Prototype for Mine Drainage Purification- (석탄광의 산성갱내배수 처리.이용.제어에 관한 연구 -한국형 특수갱배수 정화장치 시작품 현지적용실험-)

  • 이춘택
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.4
    • /
    • pp.11-21
    • /
    • 1986
  • Mine drainage from coal mines is mostly acidic, polluted and/or contaminated, even if its quantity has increased substantially during recent days. This causes two kinds of problems arising at mining districts; one is the environmental disruption and the other is insufficient water supply for living, employee's bathing and industrial purposes. In order to mitigate the aforementioned problems, a specific equipment of Korea type for mine drainage purification has been developed and its prototype manufactured, followed by its applicability tests implemented at mine site. The results of the tests indicates that the new equipment developed is much lower than and economical compared to, other existing neutralization facilities at home and abroad in capital investment at installation stage, the consumption of neutralizing chemicals at operation stage and the requirements of installation site. Whangji area where the prototype water treatment equipment is installed has been sustaining a short supply of usable water, especially in dry seasons and supplementing about 40㎥ of water brought from a location farther than 4km in distance to meet water requirements. The prototype water treatment equipment is however considered capable of providing compressor cooling water in sufficient amount from winter season In the future.

  • PDF

Economic Analysis for Equipment Replacement (기계설비 대체의 경제성 분석에 관한 사례연구)

  • 이덕수;박노국;송문익
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.36
    • /
    • pp.159-166
    • /
    • 1995
  • In order to get equipments or facilities the company evaluates the alternatives on the investment and makes a decision in terms of investment economy. Quite often, however, companies face difficulties in generating investment alternatives and evaluating the alternatives generated. This paper discusses the methods of investment evaluation and shows a case study in which a specific method is applied to a firm.

  • PDF

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

Deciding the Maintenance Priority of Power Distribution System using Time-varying Failure Rate (시변 고장률을 이용한 배전계통 유지보수 우선순위 결정)

  • Lee, Hee-Tae;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.476-484
    • /
    • 2006
  • The failure prediction and preventive maintenance for the equipment of nuclear power plant area using reliability-centered maintenance have been grown. On the other hand, the maintenance for power distribution system consists of time-based maintenance mainly. In this paper, the new maintenance algorithms for power distribution system are developed considering reliability indices. First of all, Time-varying failure rates are extracted from data accumulated at KEPCO using exponential distribution function and weibull distribution function. Next, based on the extracted failure rate, reliability for real power distribution system is evaluated for applying the effective maintenance algorithm which is the analytic method deciding the maintenance point of time and searching the feeder affecting the specific customer. Also the algorithm deciding the maintenance priority order are presented based on sensitivity analysis and equipment investment plan are analyzed through the presented algorithm at real power distribution system.

A Study on the Harmonic Current Characteristic and Emission Value Assess Method Considering the Linear Load (선형부하가 고려된 고조파 전류 특성 및 방출값 평가)

  • Park, Yong-Up;Choi, Seung-Hoon;Chang, Joon-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • In order to operate the power system satisfactory for both system operators and customers, it is important to limit the harmonic currents to the allowable levels which injected into the system from the distorting installations. In this regard, the principles for the allocation of emission limits on individual customer were introduced in the technical report of IEC61000-3-6. According to these general principles, the emission limits are dependent on the agreed power of the customer, the power of the harmonic-generating equipment, and the system characteristics. The considerations in this report are very comprehensive and the process introduced is practical enough to implement as it is. However, there is a fact not appropriately dealing in the report that could be a very tickle but has a huge impact on determining the emission limit. This is the effect of non-harmonic load currents. More precisely, these are from the equipments which do not emit any harmonic or may emit harmonics but this specific order under the consideration by themselves if the source power is sinusoidal. The load currents originated from these equipments have an effect of active filter against the specific order of harmonic therefore, these should be dealt as a significant factoron the process of determining the emission limits for individual customer.

Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

A Study on Structural Safety Management Plan for Above Ground and Underground Structure Dismantling work (지상 및 지하구조물 해체공사를 위한 구조 안전관리 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.194-195
    • /
    • 2021
  • Due to urban regeneration projects or changes in the living environment, there is an increasing need to demolish old buildings that have lost their functions. Demolition of above ground and underground structures is an important construction project that greatly affects the construction period and safety of the entire process. However, it is difficult for the safety officer to manage the demolition work due to the lack of specific and diverse data applicable to the site of the demolition plan. Therefore, in this study, items that need to be improved in structural safety when the above-ground and underground structures are demolished are reviewed and organized. For the main contents of structural safety management in demolition work, 1) structural review reflecting the order of demolition work, 2) installation and dismantling of steel pipe scaffolding and dust nets, 3) installation and dismantling of system scaffolding, 4) installation and dismantling of fall prevention nets, 5) jack support Installation and dismantling, 6) movement of equipment, movement and planning between floors, 7) equipment for demolition of structures, height of remnants, 8) site cleanup, and 9) equipment operators were categorized and arranged.

  • PDF

Valve core shapes analysis on flux through control valves in nuclear power plants

  • Qian, Jin-yuan;Hou, Cong-wei;Mu, Juan;Gao, Zhi-xin;Jin, Zhi-jiang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2173-2182
    • /
    • 2020
  • Control valves are widely used to regulate fluid flux in nuclear power plants, and there are more than 1500 control valves in the primary circuit of one nuclear power plant. With their help, the flux can be regulated to a specific level of water or steam to guarantee the energy efficiency and safety of the nuclear power plant. The flux characteristics of the control valve mainly depend on the valve core shape. In order to analyze the effects of valve core shapes on flux characteristics of control valves, this paper focuses on the valve core shapes. To begin with, numerical models of different valve core shapes are established, and results are compared with the ideal flux characteristics curve for the purpose of validation. Meanwhile, the flow fields corresponding to different valve core shapes are investigated. Moreover, relationships between the valve core opening and the outlet flux under different valve core shapes are carried out. The flux characteristics curve and equation are proposed to predict the outlet flux under different valve core openings. This work can benefit the further research of the flux control and the optimization of the valve core for control valves in nuclear power plants.

Deregulation Necessity for the Invigoration of Drone Utilization in the Geospatial Information Field

  • Heo, Joonghyeok;Park, Joonkyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.351-357
    • /
    • 2022
  • In this study, a direction for deregulation that can increase the use of drones in the field of spatial information is presented. Regulations and administrative procedures for drone operation showed similar procedures in Japan, the United States, and Korea, such as reporting flight equipment, driver's license, and prohibition of flying within a specific flight zone. In the United States, policies to encourage the use of commercial drones have been implemented, and Japan has slightly tightened regulations on drone operation to protect the Olympics and important national facilities. As a result of the study, in the area where drone operation is restricted for geospatial data construction, Korea was setting the largest area, and GIS analysis showed that Korea's drone flight restricted area was more than 19.4% of the country's land area. In order to increase the utilization of drones in the construction and utilization of spatial information in the future, it is necessary to reset the drone flight restriction zone and reduce the area of the drone flight restriction zone. In addition, it was found that Korea is the only country that has formal and specific regulations on geospatial information security management. In order to increase the construction of geospatial information using drones, it is necessary to ease GSD (Ground Sample Distance)regulations.

Improvement of Fatigue Life and Vibrational Characteristics of Composite Material Propeller Shaft of Vehicle (수송기계용 복합재료 추진축의 피로수명 및 진동특성 향상에 관한 연구)

  • 공창덕;정진호;정종철;김기범
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.104-117
    • /
    • 1999
  • The Composite materials has been used in the field of high technology industry because of high specific stiffness and high specific strength. Specially, the composite materials has been widely applied to the field of the aircraft and the transportation by the effectiveness of light weight due to low specific weight and reduction of the parts due to bonding, molding and so on. These advantages about the composite have led to study and apply in the transmission shaft for the aircraft and the drive shaft for the automobile. The composite material propeller shaft with the high vibrational stability was designed and analyzed. In order to verify the analysis, two types of experimental test which are the FFT analyzer with impact hammer and the rotational equipment were applied.

  • PDF