• Title/Summary/Keyword: Oral implant

Search Result 1,708, Processing Time 0.022 seconds

7-mm-long dental implants: retrospective clinical outcomes in medically compromised patients

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Cho, Yun Ju;Myoung, Hoon;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.260-266
    • /
    • 2019
  • Objectives: Dental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients. Materials and Methods: In this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization. Results: The implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last followup. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly. Conclusion: Within the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.

Implant complications in bruxism patients

  • Song, Ji-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.2
    • /
    • pp.149-150
    • /
    • 2021
  • Bruxism is defined as a parafunctional activity during sleep or while awake that includes locking and grinding of teeth and clenching. It generates excessive occlusal force that may lead to implant failure. Therefore, diagnosis of bruxism and providing specific protocols such as occlusal splint and/or injection of botulinum toxin before implant installation are important to prevent increases the risk of implant failure in bruxism patients.

Short-term improvement of masticatory function after implant restoration

  • Kang, Si-Mook;Lee, Sang-Soo;Kwon, Ho-Keun;Kim, Baek-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.205-209
    • /
    • 2015
  • Purpose: Dental implants present several advantages over other tooth replacement options. However, there has been little research on masticatory function in relation to implant treatment. Therefore, the aim of the present study was to evaluate the improvement of masticatory function two weeks after implant restoration. Methods: Masticatory ability was evaluated with the subjective food intake ability (FIA) and objective mixing ability index (MAI) methods. Fifty-four subjects with first and second missing molars completed the study. The subjects were asked to complete a self-reported questionnaire about 30 different food items, and to chew wax samples 10 times both before and two weeks after implant restoration. A total of 108 waxes were analyzed with an image analysis program. Results: Dental implant restoration for lost molar teeth on one side increased the FIA score by 9.0% (P<0.0001). The MAI score also increased, by 14.3% after implant restoration (P<0.0001). Comparison between the good and poor mastication groups, which were subdivided based on the median MAI score before implant restoration, showed that the FIA score of the poor group was enhanced 1.1-fold while its MAI score was enhanced 2.0-fold two weeks after an implant surgery. Conclusions: Using the FIA and MAI assessment methods, this study showed that masticatory function was improved two weeks after implant restoration. In particular, the enhancement of masticatory function by implant restoration was greater in patients with relatively poor initial mastication than in those with good initial mastication.

Masticatory function following implants replacing a second molar

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • Purpose: The aim of this study was to obtain objective and standardized information on masticatory function and patient atisfaction following second molar single implant therap. Methods: Twenty adult patient, who had restored second molar single implants more than 1 month before the study, were enrolled in this stud. All patients received a chewing test using peanuts before and after insertion of the implant prosthesi, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therap. Results: his study obtained standardized information on the masticatory function objectively (e.g., P, R, $X_{50}$) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from $67.8{\pm}9.9$ to $84.3{\pm}8.5$% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size ($X_{50}$) of Post-insertion is lower than that of Preinsertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. Conclusions: These findings indicate that a second molar single implant can increase masticatory function.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES (임플란트 표면에 따른 인공치면세균막 형성에 관한 연구)

  • Kim, Jin-Woo;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

BLOOD VESSELS OF THE PERI-IMPLANT MUCOSA: A COMPARISON BETWEEN FLAP AND FLAPLESS PROCEDURES (피판과 무피판 임플란트 수술 후 임플란트 주위 점막의 혈관분포 비교)

  • Kim, Jung-In;Choi, Byung-Ho;Xuan, Feng;Kim, Ha-Rang;Mo, Dong-Yub
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.101-105
    • /
    • 2009
  • Background: The vascularity of the peri-implant tissue is a very important parameter in establishment and maintenance of a healthy tissue after dental implant insertion. Objective: The purpose of this study was to compare the vascularity of the peri-implant mucosa between flap and flapless implant surgeries by using a canine mandible model. Study Design: In six mongrel dogs, bilateral, edentulated, flat alveolar ridges were created in the mandible. After 3 months of healing, two implants were placed in each side by either the flap or flapless procedures. After another healing period of 3 months, biopsies were obtained, prepared for light microscopy and exposed to morphometric measurements. Results: The supracrestal connective tissue lateral to the implant was found to be more richly vascularized in the flapless group than in the flap group. Conclusion: These results suggest that the flapless procedure may have an effect on increasing the vascularity of the peri-implant mucosa.

Clinical Study on Implant Survival and Graft Resorption Rate After Maxillary Sinus Bone Grafting (상악동골이식 후 임플란트 생존율 및 골이식재의 흡수율에 관한 임상적 연구)

  • Lee, Jae-Hwan;Chee, Young-Deok;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Dae-Geun;Jeon, In-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.529-536
    • /
    • 2010
  • Purpose: The Purpose of this study is to show the total survival rate of implants with maxillary sinus grafting and the effects that reach the survival rate by classifying types of graft materials, implant type, operation method, residual bone height and evaluate graft material resorption rate after sinus grafting Patients and Methods: 61 dental implants placed with sinus bone grafting in 24 patients at Wonkwang University Sanbon Dental Hospital were installed simultaneously or after regular healing. Various bone grafts (autograft, xenograft, allograft, alloplast) and fourth implant type (GSII, Xive, Implantium, Novel biocare) were used. All implants were investigated clinically and radiographically, being with average 20 months follow-up period after installation. Results: 3 fixtures were lost, resulting in 95.1% cumulative survival rate of 61 osseointegrated dental implant. Survival rate according to bone material type, Implant type, operation method, residual bone height, have no statistically significant differencies. The mean preoperative residual alveolar bone height was 4.75 mm, average postoperative height of graft materials 10.8 mm, vertical bone resorption rate was 10% after 2 years. Resorption rate according to operation method was 7% (simultaneous) and 5% (delayed) after 1 year. Conclusion: It can be suggested that maxillary sinus grafting may have predictable result with various bone graft materials and implant type, residual bone height, operation method

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study

  • Sanda, Minoru;Shiota, Makoto;Imakita, Chiharu;Sakuyama, Aoi;Kasugai, Shohei;Sumi, Yasunori
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.173-178
    • /
    • 2016
  • Purpose: Optical coherence tomography (OCT) has been investigated as a novel diagnostic imaging tool. The utilisation of this equipment has been evaluated through several studies in the field of dentistry. The aim of this preliminary study was to determine through basic experiments the effectiveness of OCT in implant dentistry. Materials and Methods: To assess detection ability, we captured OCT images of implants in each of the following situations: (1) implants covered with mucosae of various thicknesses that were harvested from the mandibles of pigs; (2) implants installed in the mandibles of pigs; and (3) implants with abutments and crowns fixed with temporary cement. The OCT images were captured before cementation, after cementation, and after removing the excess submucosal cement. Results: If the thickness of the mucosa covering the implant body was less than 1 mm, the images of the implants were clearly detected by OCT. In the implants were installed in pigs' mandibles, it was difficult to capture clear images of the implant and alveolar bone in most of the samples. Remnants of excess cement around the implants were visible in most samples that had a mucosa thickness of less than 3 mm. Conclusion: Currently, OCT imaging of implants is limited. Cement remnants at the submucosal area can be detected in some cases, which can be helpful in preventing peri-implant diseases. Still, though there are some restrictions to its application, OCT could have potential as an effective diagnostic instrument in the field of implant dentistry as well.