The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

Antimicrobial Activity of Allyl Derivate in Multi-purpose Solution as Natural Preservative (다목적용액에서 천연보존제로서의 Allyl 유도체의 항균활성)

  • Lee, Ji-Young;Suh, Seung-Kyo;Sung, Duk-Yong;Youk, Do-Jin;Lee, Koon-Ja;Chung, Jae-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • Purpose: The purpose of this study is to investigate antimicrobial activity of ally derivative of garlic against eye diseases, and to get basic data for an application development of the derivative, as a natural preservative, to multi-purpose solution (MPS). Methods: Antimicrobial activity of allyl derivative of garlic, diallyl sulfide (DAS), against Pseudomonas aeruginosa (P. aeruginosa) and Staphyloccus aereus (S. aereus) was determined. After DAS treatment in MPS of no microbial activity, its growth inhibition effect to bacteria was also determined. Results: DAS concentrations of $IC_{50}$ against P. aeruginosa and S. aereus were found when both bacteria were treated with DAS concentration of 0.25% and 0.64%, respectively. At MPS test, a product from Company A did not show any effects against both bacteria, but one from Company B showed antimicrobial activity against both bacteria. Antimicrobial activity test of the product from Company B in MPS did not showed any significant difference on both gram-negative and gram-positive bacteria. For a trial application of antimicrobial activity of DAS as a natural preservative, DAS was added to MPS of Company A which did not show any antimicrobial activity at treated concentration. Addition of DAS into MPS of Company A resulted in antimicrobial activity of DAS, which suggested a possible application of DAS as a germicide for contact lenses. Conclusions: This study showed allyl derivative of garlic has antimicrobial activity against both P. aeruginosa and against S. aereus, but more effects on P. aeruginosa. The result suggests that allyl derivative derived from garlic can be developed to a preservative of MPS as a natural substance.

  • PDF

Development of a Solar Concentrator having the Reflecting Surface with the 2m Class Diameter (직경 2m급 반사면을 가지는 태양열 집광 장치 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 2008
  • Purpose: To develop a solar concentrator having the reflecting surface with the 2m class diameter. Methods: In order to make the reflecting surface for the solar concentrator, the shape of the reflecting surface sector is required. So, first, we induced the formula that can produce this shape. After that, using Delphi 6.0 language, we developed a program which uses this formula and produces the shape and the numerical data of the reflecting surface sector with the input variables such as the external diameter of the reflecting mirror, the reflecting mirror's radius of curvature at the paraxial range, the number of reflecting mirror sector, the size of the center hole of the reflecting mirror, and the interval of the output data. Results: This program, which was developed to produce the shape and the numerical data of the reflecting surface sector, enables us to see the shape of sector on the monitor and to save the numerical data files for the shape of sector. As a result, the user of this program can easily access the numerical data of the reflecting surface sector. Conclusions: Developing the program which produce the reflecting surface sector used to make the reflecting surface of the solar concentrator, we could succeed in making the prototype products by applying it to the development of the real solar concentrator with the diameter of the 2m class.

  • PDF

Hitological Changes on the Wound Healing Process of Alkali Burned Mouse Cornea (알칼리 화상을 입은 마우스 각막에서 상처 치유과정 중 관찰된 조직학적 변화)

  • Lee, Ji-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.161-169
    • /
    • 2008
  • Purpose: To better understand the corneal regeneration after alkali burn regarding the initial clinical progression and the therapy, we investigated the changes of the multi factors following chemical injury in cornea. Methods: This study was performed to observation on the healing process of alkali burned cornea in aspect of immunohistochemistry by immunofluorescence or H-E staining and TUNEL assay. Results: The results showed that although a healing process occurred after alkali burn, apoptosis of epithelial, stromal and endothelial cells in the cornea was continuously observed. Neovascularization and expression of ${\alpha}$-smooth muscle actin (${\alpha}$-SMA) from limbus and from injured cornea, respectively, were observed after 3 days of alkali burn. Formation of collagen III in corneal stroma and increased expression of chondroitin sulfate are coincident with expression of ${\alpha}$-SMA and transforming growth factor-${\beta}$ (TGF-${\beta}$). Conclusions: These data suggest that medical treatment within 3 days of alkali burn will be effective to inhibit neovascularization and formation of collagen III and chondroitin sulfate. This study extends our immumohistochemical understanding of healing process in alkali burned cornea, and the results get in this study will be cornerstones in the development of therapeutic agent for accelerating renewal of chemical damaged cornea.

  • PDF

A Plan for Startup of Optical Shop by Ophthalmic Optics Students (안경광학과 학생들의 안경원 창업예정도)

  • Lee, Ok-Jin;Jung, Se-Hoon;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: To investigate optical shop startup awareness of ophthalmic optics students as a basic source for startup education. Methods: Total of 287 students from three ophthalmic optics college in kyung-gi region was surveyed and analyzed using SPSS analysis. Results: Optical shop startup business plan of ophthalmic optics students was very high (80.1%). For startup timing, over 6yrs of employe (37.0%) was most and there was significant difference according to age (p<.001) and optician family present (p<.05). For startup type, single startup type (37%) was most and there was significant difference according to grade (p<.01). For startup unit of space, 30 pyong (43.5%) was most, Seoul metropolitan area and kyung-gi region (54.4%) was most for startup region, and station area (40.8%) was most for startup location. The reason of non-startup was eye hospital and glass related company employe (35.7%) was most and optical shop employe (35.7%) was most for non-startup planner's way. Conclusions: Startup business plan was very high and need to have startup education for there startup provision.

  • PDF

Design of an Anamorphic Aspherical Prism Lens for the Head Mount Display (HMD용 회전 비대칭 비구면 프리즘 렌즈 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.83-88
    • /
    • 2008
  • Purpose: To design an anamorphic aspherical prism lens for the HMD optical system. Methods: First, we get the initial data, needed in design, which are distances between each surface etc., by analyzing user's demended specifications and by drawing geometrically the shape of prism lens by using CAD. Based on these data and using 'ode V' which is an optical design software, we could progress the optimization in which we treat the coefficients of the anamorphic aspherical surface as the principal variables. To reduce the cost in DTM manufacturing, we would optimize the optical system with the transmitting surface, existed in the direction of video device among 3 surfaces of the prism lens, remaining as a plane. Results: we could design one anamorphic aspherical prism lens which has the finite ray aberration of 15 ${\mu}m$, the distortion of 0.5%, and the MTF value of 0.3 over at 36 lp/mm for the video device of 12 mm ${\times}$ 9 mm size. Conclusions: We designed a prism lens used for HMD. This prism lens has the optical capacities of 15 ${\mu}m$ finite ray aberration and 0.5% distortion for the video device of 12 mm ${\times}$ 9 mm size, and become the optical system having the MTF value of 0.3 over at 36 lp/mm.

  • PDF

Amoebicidal Effect of Nephrite-containing Contact Lens Storage Case (연옥이 첨가된 콘택트렌즈 보관용기의 항아메바 효과)

  • Jung, Jae Woo;Lee, Jong Heon;Park, Sung Hee;Yu, Hak Sun;Kim, Yoon Kyung;Lee, Ji-Eun
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.5
    • /
    • pp.509-515
    • /
    • 2017
  • Purpose: To compare the amoebicidal effects of nephrite containing contact lens (CL) storage cases with conventional CL storage cases. Methods: Acanthamoeba lugdunensis were inoculated onto 5% nephrite containing CL storage cases as well as conventional CL storage cases both with and without silicone hydrogel contact lenses (SHCLs). Then the amount of Acanthamoeba proliferation on CL storage cases and the number of adherent Acanthamoeba on SHCLs were determined and compared. The effects of multipurpose solution (MPS) with and without 1% or 5% nephrite solution on Acanthamoeba adhesion were analyzed. Results: Nephrite containing CL storage cases showed more inhibitory effects on Acanthamoeba proliferation (p = 0.02) and significantly reduced the number of adherent Acanthamoeba on SHCLs compared with conventional CL storage cases, regardless of SHCLs generation (p = 0.001, p = 0.001 and p < 0.001, respectively). The number of adherent Acanthamoeba on the first generation of SHCLs was significantly reduced by MPS with 1% and 5% nephrite solutions (p = 0.03 and p = 0.004, respectively), but the numbers for the second and third generation SHCLs were not. Conclusions: Nephrite could be used as a new additive component for CL storage cases and multipurpose solutions to improve the disinfection effects on Acanthamoeba.

A Study on the Factors Affect on Opticians' Customer Orientation (안경사의 고객지향성에 영향을 미치는 요인에 관한 연구)

  • Choi, Youngro;Park, Inn-Jee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.403-411
    • /
    • 2018
  • Purpose : The purpose of this study is to analyze how the certain efforts of the optical shops affect on opticians' job satisfaction and organizational commitment, and to analyze how opticians' job satisfaction and organizational commitment affect on the customer orientation and to suggest the method of maintaining competitiveness. Methods : Two hundred opticians took participations on the surveys via the Internet survey method and social network system (SNS), and SPSS 18.0 statistics program was used for data analysis; frequency analysis, T-test, factor analysis, reliability analysis, and multiple linear regression analysis were conducted. Results : It is analyzed the differences on the job satisfaction and organizational commitment in accordance with type of optical shops, conducting 5 working days/week and flexible time. As a result, higher job satisfaction is presented with 5 working days/week. Relationships with co-workers statistically affect on job satisfaction positively and emotional labor and work overload statistically affect on job satisfaction negatively. In addition, relationships with co-workers and reward statistically affect on organizational commitment positively and emotional labor and work overload statistically affect on organizational commitment negatively. And opticians' job satisfaction and organizational commitment statistically affect on customer satisfaction positively. Conclusion : It is necessary for the optical shops to make an effort for their opticians to improve the job satisfaction and organizational commitment. And to do so, it is needed to form trusting and respecting relationships with co-workers or superiors. In addition, it is necessary to have continuous communication and education for opticians' self-management. Also, it is needed to establish an effective reward system.

Acute Cytotoxicity Testing of Polyhexamethylene-biguanide (PHMG) and Epigallocatechin-gallate (EGCG) Mixture on the Cultured Human Corneal Epithelial Cell (보존제 PHMB(polyhexamethylene biguanide)-EGCG(epigallocatechin gallate) 혼합물의 각막상피세포 급성독성 평가)

  • Kim, Nam-youl;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.531-541
    • /
    • 2018
  • Purpose : To evaluate the acute cytotoxic effect of polyhexamethylene biguanide (PHMB), epigallocatechin gallate (EGCG) and PHMB/EGCG mixture on the cultured human corneal epithelial cell (HCEpiC). Methods : HCEpiCs were cultured in the media of HCEpiC containing 0.00001~0.005% PHMB, 0.001~5% EGCG and 0.00005% PHMB/0.05% EGCG mixture respectively for 30, 60, 120 and 240 min. Cultured HCEpiCs were fixed and stained with Draq5 and cell viability and apoptosis were evaluated using confocal microscope and ImageXpress $Ultra^{TM}$. Results : Cultured HCEpiC did not show cytotoxic effect at below 0.00005% PHMB and below 0.05% EGCG concentration. In the media containing 0.00005% PHMB/0.05% EGCG, acute cytototoxic effect was not found, whereas damaged HCEpiCS were increased and survival cells were decreased in the media incubated for 240 min. Conclusion : The mixture of 0.00005% PHMB/0.05% EGCG showed non acute cytotoxic effect on the cultured HCEpiCs, however it is needed to investigate its chronic cytotoxic effect.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.