• Title/Summary/Keyword: Optometry

Search Result 583, Processing Time 0.018 seconds

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Change of Contrast Sensitivity in Peripheral Vision Following Eccentric Viewing Training (중심외주시 훈련 후 주변시야에서의 대비감도 변화)

  • Seo, Jae-Myoung;Lee, Ki-Young;Lim, Yong-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • Purpose: This study was to investigate the functional improvement in peripheral vision following eccentric viewing training. Methods: 14 subjects with normal vision took a part with their right eye, peripheral retinal which is $20^{\circ}$ lateral area from the fovea was examined for contrast sensitivity(CS). Eccentric viewing training was performed for 21days with an hour image viewing and examination was repeated. Results: The critical durations for 0.7 cpd were increased 2.67(467 ms) for pre-eccentric viewing training to 2.79(616 ms) for post-eccentric viewing training (p>0.05). The critical durations for 3.0 cpd were also increased 2.53(341 ms) for pre-eccentric viewing training to 3.04(1102 ms) for post-eccentric viewing training (p>0.05). Conclusions: It is recommended to use higher spatial frequency with higher CS for eccentric viewing training and to train more frequently for a short time. Moreover, the study on Korean standardizing of the visual rehabilitation for low vision based on the etiology is sorely required.

Binocular Visual Functions Effect of Vision Therapy Programs : A Meta-Analysis (Vision Therapy 프로그램의 양안시기능 개선 효과에 대한 메타분석)

  • Lee, Jeong-Yun;Park, Chun Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.201-210
    • /
    • 2015
  • Purpose: In order to aggregate effect of the improvement of binocular vision function by vision therapy, total mean effect size, mean effect size by dependent variables, and effect size by characteristics of the subjects and characteristics of treatment were analyzed by meta-analysis. Methods: We analyzed data from 14 Korean National primary studies, which reported effects of vision therapy programs, using meta-analysis. Results: The effect size of total mean was 1.207, which showed high effect. The mean effect size according to the subcategory of the binocular dysfunctions was the highest for vergence dysfunctions group (2.989), followed by accommodative dysfunctions group (0.868) and group with both vergence dysfunctions and accommodative dysfunctions (0.692). The effect size according to the characteristics of the subjects was the highest in the vision therapy conducted in the binocular dysfunctions group (2.509) that had no other dysfunctions. The mean effect size according to the number of programs was the highest (2.310) for 7 times a week. Vision therapy for improving the binocular functions was the most effective (2.019) in 8 weeks later from vision therapy start. Conclusions: It can prove that the therapy for the improvement of binocular vision function is effective through that each result of the vision therapy effect is converted to mean effect size, and being objectifying the mean effect size.

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

The Study of Kinetic Visual Acuity in College Students (대학생의 동적시력에 관한 연구)

  • Shim, Moon-Sik;Kim, Sang-Hyun;Kang, Hye-Sook;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • Purpose: We were to obtain the basic data for studying kinetic visual acuity through the comparative analysis in kinetic visual acuity, visual acuity, refractive error, pupil size, and hand reaction time for college students. Methods: We had tested the kinetic visual acuity, visual acuity, refractive error and hand reaction time using the kinetic visual acuity tester (KOWA AS-4A), the hand reaction time program and auto-refractometer for thirty-nine male and same female optometry students with more than +0.1 LogMAR visual acuity in both eyes. And the results were examined gender differences of kinetic visual acuity and the factors correlation. Results: In the measured values of male, pupil size were 6.00 mm, hand reaction time 0.23 msec, refractive error -1.66 D, visual acuity -0.07, kinetic visual acuity 0.59 and pupil size 5.86 mm, hand reaction time 0.24 msec, refractive error -2.08 D, visual acuity -0.02, kinetic visual acuity 0.46 in female. It was significant difference for kinetic visual acuity values but other factors were not. The kinetic visual acuity and left visual acuity had the highest correlation, r=-0.406. The kinetic visual acuity indicated more excellent values in the case of increasing visual acuity and decreasing myopia amount. Conclusions: It was able to see that male college students were better than female for kinetic visual acuity and the visual acuity were related to kinetic visual acuity.

The Visual Distribution Map Based on the Geographic Information System for Ocular Health State (지리정보체계를 이용한 눈 건강수준의 시각적 분포도)

  • Kim, Hyojin;Kim, Hyi Jin;Park, Chang Won;Lee, Eun-Hee;Kim, Hee Ju;Ryu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.493-498
    • /
    • 2014
  • Purpose: This study utilized the Geographic Information System (GIS) which is one of the representative methods for describing visual distribution, to show the distribution of visions of middle and high school students in 16 cities or provinces in Korea. Method: The data of National Health and Nutrition Examination Survey (NHANES) were analysed from 2009 to 2011 and designed a population-based cross-sectional study. The subjects were total 1,049 students at the age of 13 to 18 and uncorrected vision was provided. Male subjects were 549 (52.3%) and female subjects were 500 (47.7%). Subjects were divided into 16 cities or provinces and average vision of regions were analysed. the differentials of vision among the regions were analysed by as a spatial analysis method. Results: The average uncorrected vision were significant difference by sex (p=0.001). However male and female student groups' average vision indicated no statistically significant difference by region in those 16 cities and provinces. In order to show the differentials of middle and high school students' vision by region with a visual distribution method, the GIS was utilized for mapping. Conclusions: The differentials of vision among regions by GIS provide a visually effective distribution map.

An Evaluation of the Virtual Refraction Education (가상 굴절검사 교육에 대한 평가)

  • Yu, Dong-Sik;Son, Jeong-Sik;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.43-50
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effect of a VR (Virtual Refractor), which is a simulator for a PR (Practical Refraction), as an educational tool. Methods: Twenty four third year students enrolled in the department of visual optics volunteered for VR education. Each student attended a VR training course and practiced with the VR by themselves. One month later, each student tested three virtual subjects on the VR and one real subject on the PR and were given a performance score for each refraction. And the scores for the virtual and practical refractions were compared. In addition, a self-report questionnaire based on a five point Likert-scale was designed, consisting of domains such as spontaneous participation, contribution for the refraction, confirmity of the VR and PR, and necessity of the VR. Results: The Spearman's correlation coefficient between the testing score of the practical and virtual refractions indicated a significantly correlation (R=0.71, p<0.001). In the questionnaire, the mean score of the domains was 3.67${\pm}$0.96 and it indicated that students expressed that using the VR was beneficial. The correlation value among these domains was a high significant level, 0.91~0.68 (p<0.001). Conclusions: Although the VR required certain improvements in its concentration and systematic approaches for practical situations, it showed a high correlation between the VR and the PR and represented a positive evaluation in the PR.

  • PDF

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

Research a Person's Eyesight Changes on According to the Optimum Color Temperature for the Stand Lamp Using White Light LED Sources (백색광 LED를 사용한 독서등의 최적 색온도에 따른 사람의 시력 변화 연구)

  • Kim, Juhyun;Chang, Wonbeom;Lee, Seokhwan;Jung, Kwangkyo;Kim, Donghyun;Kim, Jeongmi;Ryu, Jaejun;Moon, Seongdeuk;Lee, Seunghyun;Ko, Youngsu;Huh, San;Jang, Mina;Jung, Changho;Chang, Jiho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.80-82
    • /
    • 2013
  • White light emitting diode (LED) determined the most appropriate color temperature in reading lighting evaluated fatigue degree of eye according to color temperature. The eye fatigue degrees are determined by brightness and color temperature. Therefore, we measured the results of eyes test according to the change of color temperature and brightness. Experiments except for astigmatic corrected visual acuity of 0.8 more and age 20 to 25 years old, male and female college students was conducted in 100 patients. And constant illumination conditions, visual acuity was measured by varying the color temperature. The optometry at 10 minutes in the darkroom adapted eye. And then the temperature of $25{\pm}3$ degrees, the humidity was carried out at $50{\pm}5%$. As a result of typical color temperature of white light (5,600 K) has identification of the readability.

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.