• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.025 seconds

Color-Matching Liquid Crystal Display using a Lenticular Lens Array and RGB Light Sources

  • Jeon, Hwa Joon;Park, Gyeungju;Gwag, Jin Seog;Lee, Jong Hoon;Kwon, Jin Hyuk
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.345-349
    • /
    • 2014
  • A direct-lit color-matching liquid crystal display using a lenticular lens array with grouped lens elements that image linear RGB light sources on the RGB subpixels of a color filter to enhance transmittance is designed, simulated, and fabricated. The RGB LED linear light sources were fabricated using small RGB LEDs in a linear array arrangement, and the lenticular lens array consisted of eight units of the same structure with a gap of 2.19 mm. The optical transmittance of the liquid crystal panel was improved by as much as 240% due to the color matching.

Effect of Additive Composition on Fracture Toughness of In Situ-Toughened SiC−Si3N4 Composites

  • Lee, Young-Il;Kim, Young-Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.4 s.299
    • /
    • pp.189-193
    • /
    • 2007
  • Effect of additive composition on fracture toughness of in situ-toughened $SiC-Si_3N_4$ composites was investigated for five different additive compositions. The highest toughness $(6.4MPa{\cdot}m^{1/2})\;in\;SiC-Si_3N_4$ composites investigated herein was obtained when an Y-Mg-Si-Al-O-N oxynitride glass was used as a sintering additive. The improvement in fracture toughness was produced by enhanced bridging and deflection by $Si_3N_4$ grains.

Photoluminescence of Hexagonal Boron Nitride (h-BN) Film

  • Jin, Moon-Seog;Kim, Nam-Oh
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.637-639
    • /
    • 2010
  • Hexagonal boron nitride (BN) films were prepared. The process involved, spraying BN powder-dispersed $H_3BO_4-BCl_3$-ethyl alcohol solution on quartz plates, and the drying off quartz plates before, and annealing at $1070^{\circ}C$ in a nitrogen atmosphere. The optical energy band gap of the BN films was 5.28 eV. Photoluminescence peaks with energies of 3.44, 3.16, 2.97, and 2.35 eV at 10 K were observed and analyzed. Accordingly, these have resulted from donor-acceptor pair recombinations.

Accelerating repaired basement membrane after bevacizumab treatment on alkali-burned mouse cornea

  • Lee, Koon-Ja;Lee, Ji-Young;Lee, Sung Ho;Choi, Tae Hoon
    • BMB Reports
    • /
    • v.46 no.4
    • /
    • pp.195-200
    • /
    • 2013
  • To understand the corneal regeneration induced by bevacizumab, we investigated the structure changes of stroma and basement membrane regeneration. A Stick soaked in 0.5 N NaOH onto the mouse cornea and 2.5 mg/ml of bevacizumab was delivered into an alkali-burned cornea (2 ${\mu}l$) by subconjunctival injections at 1 hour and 4 days after injury. At 7 days after injury, basement membrane regeneration was observed by transmission electron microscope. Uneven and thin epithelial basement membrane, light density of hemidesmosomes, and edematous collagen fibril bundles are shown in the alkali-burned cornea. Injured epithelial basement membrane and hemidesmosomes and edematous collagen fibril bundles resulting from alkali-burned mouse cornea was repaired by bevacizumab treatment. This study demonstrates that bevacizumab can play an important role in wound healing in the cornea by accelerating the reestablishment of basement membrane integrity that leads to barriers for scar formation.

Optical System with 4 ㎛ Resolution for Maskless Lithography Using Digital Micromirror Device

  • Lee, Dong-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.266-276
    • /
    • 2010
  • In the present study, an optical system is proposed for maskless lithography using a digital micromirror device (DMD). The system consists of an illumination optical system, a DMD, and a projection lens system. The illumination optical system, developed for 95% uniformity, is composed of fly's eye lens plates, a 405 nm narrow band pass filter (NBPF), condensing lenses, a field lens and a 250W halogen lamp. The projection lens system, composed of 8 optical elements, is developed for 4 ${\mu}m$ resolution. The proposed system plays a role of an optical engine for PCB and/or FPD maskless lithography. Furthermore, many problems arising from the presence of masks in a conventional lithography system, such as expense and time in fabricating the masks, contamination by masks, disposal of masks, and the alignment of masks, may be solved by the proposed system. The proposed system is verified by lithography experiments which produce a line pattern with the resolution of 4 ${\mu}m$ line width.

Awareness Toward Child Abuse of Parents With the Elementary School Students

  • Kim, Yoseob;Park, Inn-Jee;Kim, Taehoon
    • International Journal of Contents
    • /
    • v.9 no.3
    • /
    • pp.42-47
    • /
    • 2013
  • The purpose of the present study was to investigate the degree of awareness toward child abuse behaviors, causes of child abuse, and the necessity of the parent education for child abuse prevention in the parents of elementary school students. Four hundred fifty parents of elementary school students participated for this study. The results were as follows. First, the parents generally were aware of emotional abuse and physical abuse, but not aware of neglect. In the comparison, according to parental education level and family income, highly educated parents and high-income parents were more aware of both emotional abuse and neglect. Second, most of the parents agreed on the causes of child abuse presented in the survey except the cause of having an unexpected child. Third, most parents agreed on the necessity of parent education programs for child abuse prevention. The discussion for the results and strategies for child abuse prevention was provided.

Lens Design of the Eyepiece Combined with the Accommodation-dependent Navarro Eye at an On-axis Point

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2010
  • We introduce a new method for lens design that combines an eyepiece with the finite model eye, to make a corrected version of the accommodation-dependent Navarro eye. The optical system that we designed, which includes a human eye, takes into account the aberration of the eye and increases the performance of the image in the retina. In the design results, for the optimized eyepiece combined with the corrected Navarro eye, visual acuity is 1.40. Compared with the existing method of eyepiece design using inverse ray tracing with the corrected Navarro eye, MTF value was recorded as 0.079 to 0.283 at 160 lp/mm and visual performance was improved.

Fast Measurement of Eyebox and Field of View (FOV) of Virtual and Augmented Reality Devices Using the Ray Trajectories Extending from Positions on Virtual Image

  • Hong, Hyungki
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.336-344
    • /
    • 2020
  • Exact optical characterization of virtual and augmented reality devices using conventional luminance measuring methods is a time-consuming process. A new measurement method is proposed to estimate in a relatively short time the boundary of ray trajectories emitting from a specific position on a virtual images. It is assumed that the virtual image can be modeled to be formed in front of one's eyes and seen through some optical aperture (field stop) that limits the field of view. Circular and rectangular shaped virtual images were investigated. From the estimated ray boundary, optical characteristics, such as the viewing direction and three dimensional range inside which a eye can observe the specified positions of the virtual image, were derived. The proposed method can provide useful data for avoiding the unnecessary measurements required for the previously reported method. Therefore, this method can be complementary to the previously reported method for reducing the whole measurement time of optical characteristics.

Fast Estimation of Three-dimensional Spatial Light Intensity Distribution at the User Position of an Autostereoscopic 3D Display by Combining the Data of Two-dimensional Spatial Light Intensity Distributions

  • Hyungki Hong
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.307-312
    • /
    • 2024
  • Measuring the three-dimensional (3D) spatial light intensity distribution of an autostereoscopic multiview 3D display at the user position is time-consuming, as luminance has to be measured at different positions around the user position. This study investigates a method to quickly estimate the 3D distribution at the user position. For this purpose, a measurement setup using a white semitransparent diffusing screen or a two-dimensional (2D) spatial sensor was devised to measure the 2D light intensity distribution at the user position. Furthermore, the 3D spatial light intensity distribution at the user position was estimated from these 2D distributions at different viewing distances. From the estimated 3D distribution, the characteristics of autostereoscopic 3D display performance can be derived and the candidate positions for further accurate measurement can be quickly determined.

The Evaluations of Phoria and AC/A Ratio by Watching 3D TV at Near (3D TV 근거리 시청에 따른 사위도와 조절성폭주비 평가)

  • Son, Jeong-Sik;Kim, Dong-Su;Kim, Jung-Ho;Kim, Jae-Do;Hamacher, Alaric;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.319-324
    • /
    • 2015
  • Purpose: This study was designed to evaluate the changes of phoria and calculated AC/A ratio, and their recovery time points by watching 3D television (3D TV). Methods: 50 subjects (male 30, female 20) of 20s to 40s ages who can watch 3D, were measured phoria using a Howell phoria card at 3 m for distance and 40 cm for near. The phoria was evaluated before watching 3D TV and every 10 minutes from starting of watching 3D TV for 30 minutes, and every 5 minutes after finishing of watching 3D TV for 30 minutes again. Results: For the distance phoria during and after watching 3D TV, it was increased to more exophoria $-0.98{\pm}1.37{\Delta}$ (prism diopters) after 10 minutes from starting of 3D TV watching (p=0.063) and increased to more exophoria $-1.00{\pm}1.28{\Delta}$ after 30 minutes (p=0.024), and started to decrease after finishing of watching 3D TV and recovered to the level of before 3D TV watching ($-0.78{\pm}1.11{\Delta}$) after 20 minutes (p=0.32) with comparing to phoria of before watching 3D TV ($-0.80{\pm}1.12{\Delta}$). For the near phoria, it was also increased to more exophoria $-5.71{\pm}4.45{\Delta}$ after 10 minutes from starting of watching 3D TV (p=0.000) and $-6.58{\pm}4.36{\Delta}$ after 30 minutes (p=0.000), and started to decrease after finishing of watching 3D TV and recovered to the level of before watching 3D TV after 20 minutes ($-4.34{\pm}3.67{\Delta}$) (p=0.32) with comparing to the phoria of before watching 3D TV ($-4.36{\pm}3.66{\Delta}$). AC/A ratio was decreased from $4.92{\pm}1.17{\Delta}/D$ for before 3D TV watching to $4.11{\pm}1.50{\Delta}/D$ for after 30 minutes from starting of watching 3D TV (p=0.000), and increased after the end of watching 3D TV and recovered to the level of before 3D TV watching ($4.93{\pm}1.18{\Delta}/D$) after 25 minutes (p=0.598). Conclusions: During watching 3D TV at near, it showed a tendency of convergence insufficiency by decrease of calculated AC/A ratio as result that exophoria at near was higher increased than exophoria at distance. However, the increased exophoria at both near and distance was recovered to the level of base line after 25 minutes from the end of watching 3D TV. Through this study, it seems to need rational proposals of advice for watching 3D TV.