• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.026 seconds

Research on the marketability of eyeglasses and contact lenses (안경과 콘택트렌즈의 시장성 조사)

  • Kim, Bong-Hwan;Han, Sun-Hee;Park, Jae-Man;Lee, Jeong-Soo;Jeong, Ji-Hwan;Yoon, Nam-Kyung;Kim, Hyung-Soo
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.2
    • /
    • pp.1535-1542
    • /
    • 2021
  • Purpose. This study categorizes vision correction subjects by age and gender, and aims to find out which glasses or contact lenses the subjects of each age group show preference based on the answers of the questionnaires answered by the subjects. Methods. A study was conducted in the form of a questionnaire through SNS on the types of correction tools used for the purpose of correcting ametropia for the general public from their teens to their 50s. Results. As for the most preferred method for correcting asymmetry, in the case of teenagers, glasses were the most common at 50%, glasses and contact lenses the most at 43.8% each, and glasses in their 30s at 50%. Those in their 40s had the most glasses at 75%, and those in their 50s wore glasses and sunglasses at 50%. Conclusions. Since the demand for vision correction and eye protection methods varies according to age and gender, it is necessary to identify and design the flow of these demands in the existing market. Therefore, it is necessary to make a judgment that can contribute to the development of eye health targeting the main customer base and the provision of appropriate services to consumers.

Comparison of tear film break-up time and high order aberration according to soft contact lens material (소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

Analysis of changes in ocular function according to beats per minute (BPM) (분당비트수(BPM)에 따른 안기능 변화 분석)

  • Bong-Hwan Kim;Sun-Hee Han;Chan-heum Kang;Hyeon-seok Lee;Dong-uk Kwon;Chae-won Park;Hyung-Soo Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1639-1643
    • /
    • 2023
  • Purpose. We wanted to find out how the changes in brain function affected by the beats per minute (BPM) of music affected visual function. Methods. The subjects were 40 people in their 20s (30 men, 10 women) with no eye disease, strabismus, amblyopia and a corrected visual acuity of 1.0 or higher. Wearing headphones while excluding surrounding noise as much as possible, we played music while adjusting the beat rate at 40 BPM intervals from 80 to 200 BPM. Then, pupil size measurement, lag of accommodation test, and minus lens addition method maximum accommodation test were performed and analyzed. Results. As a result of analyzing changes in visual function according to beats per minute [BPM], it was found that although sound can be consciously affected, it does not directly affect visual function significantly in terms of accommodative lag and changes in pupil size. It was confirmed that the effect was limited to the maximum accommodation. Conclusions. In clinical practice, it is necessary to conduct a refraction test while keeping in mind that there are changes in visual function depending on the BPM of surrounding sounds.

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

A Study on Digital Healthcare Optometry System Using Optometry DB

  • Kim, Do-Yeon;Jung, Jin-Young;Kim, Yong-Man;Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.9
    • /
    • pp.155-166
    • /
    • 2021
  • Recently, digital health care technology is spreading and developing in various fields. Therefore, in this paper, we realized that the field to which digital healthcare technology is not applied is the field of optometry, and implemented a digital healthcare optometry system for precise lens manufacturing. A device called Phoroptor is used to manufacture the lens, and this device sets the lens by measuring the visual acuity of the person who requested the glasses. And when the person to be measured wears glasses, a device called a PD meter is used to align the pupil center and lens focus. However, there is a limit to the convenience of precise lens production and optometry due to the absence of a database and program that can accumulate and analyze the PD measurement error, inconvenience and error due to manual control of the Phoroptor, and optometric information. Therefore, in this paper, PD meter design for more accurate PD measurement, Phoroptor design and Phoroptor control application design for automatic Phoroptor control, and a database and analysis program that automatically set lenses using optometry information for each subject had been designed. Based on this, ultimately, a digital healthcare optometry system using an optometry database has been implemented.

Effects of Sweat on the Metal Frames of Eyeglasses (땀이 금속안경테에 미치는 영향)

  • Kim, So Ra;Choi, Myung Jin;Hwang, Jae Weon;Kim, Myung Soo;Chung, Seo Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Purpose: In this paper, the changes in eyeglasses frames were investigated when the frames were exposed to artificial sweat. Methods: The changes in surface, hardness, and tensile strength of eyeglasses frames made of nickel silver, Monel, and titanium were tested after the exposure to the artificial sweat of pH 6.5, 6.0, and 5.0, during 1, 3, and 6 week(s), for each. Results: Corrosion pattern of eyeglasses frames made of nickel silver, Monel, and titanium was induced by artificial sweat, and the patterns were different from another frame materials. In proportion to the pH of artificial sweat and exposure time to artificial sweat, hardness of all frames made of three different material decreased, however, tensile strength of the three frames was not changed. Conclusions: The necessity of routine management for eyeglasses frames can be suggested since the changes in surface corrosion and hardness of eyeglasses frames induced by sweat were shown.

The Effect of Stereoscopic Vision According to Lens Color Change of Sunglasses (선글라스의 렌즈 색상 변화가 입체시에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Ji-Eun;Kim, Hye-Ryeong;Kang, Bo-Gyeong;Park, Jeong-Hyeon
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1083-1088
    • /
    • 2018
  • Purpose. The purpose of this study was to investigate the effect of lens color of sunglasses on stereoacuity by experiment. Methods. We conducted a stereotaxic test using a RANDOM DOT with a polarizing lens at an examination distance of 40 cm in 100 men and women aged 20 to 60 years without any specific ocular disease. Then, seven kinds of PVC color film such as yellow, black, brown, red, purple, blue and green were put on the polarizing lens and the stereoscopic examination was carried out again. Results. When the lens color of the sunglasses is yellow, black, and brown, it affects less stereoscopic effect. However, red, purple, blue, and green have much influence on stereoscopic effect. Especially, the red and purple colors affected the stereoscopic vision. In blue and green, the effect of stereoscopic vision was different according to the people. Conclusions. Depending on the lens color of the sunglasses, stereoscopic vision is affected, which can cause problems in binocular vision. Therefore, when choosing sunglass lens color, many buyers need to pay attention.

Analysis of Eye Fatigue and Change of Eye Temperature according to Smartphone Usage Time (스마트폰 사용 시간에 따른 안구온도 변화와 눈의 피로도 분석)

  • Sun-Hee, Han;Bong-Hwan, Kim;Hyeong-Su, Kim;Jae-Wan, Jeong;Ji-Ae, Park;Chi-Hwan, Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.2
    • /
    • pp.1594-1599
    • /
    • 2022
  • Purpose. To investigate the relationship between changes in eye temperature and eye fatigue according to smartphone usage time. Methods. 15 adults in their 20s were asked to watch a smartphone, and the ocular surface temperature was measured 5 times each using a non-contact infrared thermometer every 10 minutes, and the change was observed. Result. The ocular surface temperature was 36.40℃ at the center of the cornea before watching the smartphone, but increased by 0.19℃ to 36.59℃ after watching the smartphone (SD 36.50±0.10). In addition, in the case of the sclera, it was found that the increase was 0.1℃ from 36.48℃ before viewing to 36.58℃ after viewing (SD 36.53±0.05). Conclusion. It was found that there is a close relationship between smartphone use and changes in eye temperature. In the future, it is thought that the ocular surface temperature can be used as basic data to objectively evaluate eye fatigue.

A Study on Ocular Disease by Ages in Ulsan (울산지역의 연령별 안질환에 관한 연구)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jo-Eun;Baek, Jin-Hee;Seo, Jin-Yun;Chu, Sun-Jin;Park, Jun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.403-406
    • /
    • 2014
  • Purpose: In this study, we studied ocular disease by age in Ulsan. Methods: We checked medical record of 300 patients who visited eye clinic in Ulsan. Results: The main ocular disease on the age of 10 was keratitis, that of 20 was dry eye syndrome & keratitis, that of 30 was chalazion & conjunctivitis, that of 40~50 was conjunctivitis, that of 60 was conjunctivitis & cataract. Conclusions: The main cause of ocular disease of 10~20's are unsuitable wear of contact lenses & long-time use of smart phone as well as computer. That of 30~50's are allergic conjunctivitis and chemical material reaction as well as other several factors. Especially, attack rate of conjunctivitis of 30~50's is higher than city because of industrial area (Ulsan). The main cause of ocular disease in 50~60's is a kind of senility. Therefore, based on the results of this study, it could be used the basic data of education on ocular disease prevention in Ulsan.

A Survey about Wearing Soft Contact Lenses for Astigmatism Correction of The Local College Students, Gyeongsangnam-Do, Korea (경남지역 대학생들의 난시 교정용 소프트 콘택트렌즈의 착용에 관한 설문조사)

  • Kim, Bong-Hwan;Han, Seon-Hee;Kim, Dae-Hyeon;Byeon, Sang-Hyeon;Chae, Jeong-Im;Kim, Jae-Seok;Hwang, Yun-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.3
    • /
    • pp.378-389
    • /
    • 2015
  • Purpose. The actual status of wearing toric soft contact lenses was investigated to learn why it is not used although it is required. Materials and Methods. This study has studied 64 contact lens wearing the local college students, Gyeongsangnam-do who are 20.17(${\pm}0.70$)years old, by measuring their refractive power and over-refractive power with auto refractometer(HRK-8000A, Huvitz, Korea). In addition to that, a survey was done to figure out why they do not wear toric soft contact lenses, the purpose of using toric soft contact lenses, whether they have astigmatism or any knowledge about it, the kinds of contact lens, whether they are willing to buy corrective lenses, and how they are satisfied after purchasing them. Results. 17 students (21.9%) said they experienced light-spread; 9 students (14.1%)said that they have dizziness when they wear contact lens all day long. In the survey to see whether they had astigmatism or not, 37 students (57.8%) said they had it. For the reason they do not wear toric soft contact lenses, 33 students (51.6%) said that "they were prescribed regardless of astigmatism in the optometrist." To the question asking if they are willing to buy toric soft contact lenses according to the existence of astigmatism, 51 students (79.6%) answered they are. 31 students (48.4%) said they heard a description about astigmatism at the time of purchase for contact lens. Conclusion. As the ways for any people who need to correct astigmatism to wear corrective lens, enough education about astigmatism and consistent follow-up management are needed, where the role of optometrist is considered important.