• Title/Summary/Keyword: Optokinetic nystagmus test

Search Result 4, Processing Time 0.02 seconds

Clinical significance of saccade test, smooth pursuit test, and optokinetic nystagmus test in nystagmography (안진검사에서 단속운동검사, 시추적검사, 시운동성 안진검사의 임상적 의의)

  • Choi, Yoon Seok;Na, Hyung Gyun;Song, Si-Youn;Kim, Yong-Dae;Bae, Chang Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • Background: Saccade test, smooth pursuit test, and optokinetic nystagmus test are clinically useful tests to accurately diagnose vertigo. However, there have only been a few studies regarding a correlation between the anatomical site of the lesion and the abnormality of eyeball movement in patients with vertigo. Methods: The medical records of 97 patients with vertigo between January 2006 and June 2008 were reviewed retrospectively. We classified many kinds of abnormalities regarding the saccade test, smooth pursuit test and optokinetic nystagmus test into several categories and analyzed the localizing lesion of vertigo. Results: According to the saccade test, both total saccade abnormality (S-total) and slow velocity of saccade (S-type 3) were shown to be significantly higher in the central lesion of vertigo. According to the smooth pursuit test, symmetrical unidirectional smooth pursuit abnormality (SP-type 2) was observed to be significantly higher in the peripheral lesion over vertigo. Moreover, according to the optokinetic nystagmus test, total optokinetic nystagmus abnormalities (OKN-total) were shown to be significantly useful findings in the diagnosis of the central lesion of vertigo. The coexisting abnormalities of all three tests (S+SP+OKN abnormalities) were shown to be significantly higher in the central lesion of vertigo. Conclusion: These results suggest that all these tests, saccade test, smooth pursuit test, and optokinetic nystagmus test, are very useful to distinguish between the central lesion and the peripheral lesion of vertigo. However, these tests are not beneficial in localizing the central lesion of vertigo.

Development of Simulator for Evaluation Balance by Using Vestibuloocular Reflex (전정안구반사를 이용한 평형감각 평가용 시뮬레이터의 개발)

  • 임승관;김규겸;정호춘;진달복;김민선;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.157-162
    • /
    • 1997
  • The purpose of this study was to develop a sinusoidal rotatory chair systim for evaluating the vestibular function in patients suffered from vertigo with vestibualr disorders. The sinusoidal rotatory chair system is composed of a rotatory chair systim and softwares. Maximum velocity of the rotatiry chair was upto 60 degree per second and frequency range was 0.01 to 0.64 Hz. To evaluate the vestibular function in vertigo patients, vestibuloocular reflex was measured by sinusoidal rotation of the whole body about vertical axis in the darkness, and optokinetic nystagmus, visual vestibuloocular reflex , and visual supression test were also performed. Eye movement was measured by means of a electronystgmograph amplifier through Ag-AgCI surface electrodes. Gain, phase, and symmetry were obtained from analysis of the eye movement ineuced by vestibular or visual stimulation. In healthy adults, sinusoidal rotation of the shole body produced nystagmus, of which gain was directly proportional to the velocity of stimulation. The gain of visual vestibuloocular reflex or optokinetic nystagmus, and it was suppressed markedly by visual suppression test. These results suggest that the sinusoieal rotatory chair systim which was developed by this study can evaluate the vestibular function quantitatively, also this system is very useful to diagnose and to dstimate the vestibualr function during recovery from vertigo

  • PDF

Functional Exploration of Optokinetic System by a Full Visual Field Stimulation

  • Kim Nam Gyun;KOPP C.
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.125-130
    • /
    • 1989
  • In the present study, we described a test to explore the function of optokinetic system which subjected to a full visual field stimulation using two different stimulus images patterns. Our results were interesting in a point of view that the stimulation image pattern had non- neglisible influence on the optokinetic response and that in a bidimensionnel image such as the randomly distributed spots images pattern the linearity of system was assured upto the stimulus velocity of about 50 deg/sec for normal subject. As for measuring human optokinetic after nystagmus, the regular stripes pattern was rather desirable than the randomly distributed spots pattern in this study.

  • PDF

Objective Visual Acuity Test Using Nystagmus (Nystagmus를 이용한 객관적 시기능 검사에 관한 연구)

  • 이인범;김민섭;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.103-105
    • /
    • 2000
  • Optokinetic nystagmus(OKN) testing is an useful tool for assessment of human visual function. Specially, this method has been used for assessing visual function in infants and malingering patients. OKN drum and OKN tape are the common devices currently used for clinical cases. In this paper, we present newly the automated and computerized method for the quantitative and objective assessment of visual acuity in OKN testing.

  • PDF