• 제목/요약/키워드: Optimum rate

검색결과 4,172건 처리시간 0.036초

소형 에어리프트 펌프의 성능특성에 관한 연구 (A Study on Performance Characteristics of Small Airlift Pump)

  • 오세경;이강용
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.34-39
    • /
    • 2000
  • Performance data in the literature on air lift pumps have been based primarily on pumps of long length and large diameter (high lift pumps). Since mariculture operations involve pumps of relatively short length and small diameter, performance data are required for efficient operation. To provide such data, an experimental apparatus was designed and fabricated to test all lift pumps from 2.1 to 3.4 cm inside diameter and from 40 to 300 cm in length. Instrumentation was provided to measure water flow rate and air flow rate as well as water temperature, air temperature, and pressure throughout the system. Results from this study correlate well with high lift pump data in that, for a given pump geometry, maximum water flow occurs for a specific air flow rate. Driving the pump with air flows larger or smaller than this optimum flow rate will decrease the pumping rate. The optimum flows are significantly different for low lift pumps compared to high lift pumps. However, the pumping rate for low lift pumps approaches that for high lift pumps with increasing length.

  • PDF

역삼투 복합막 제조(I) 폴리설폰지지체 계면중합 역삼투용 복합막 제조 (A Study on Reverse Osmosis Composite Membrane with Polysulfone Supporting Membrane)

  • 김명만;박종원;민병렬
    • 멤브레인
    • /
    • 제4권1호
    • /
    • pp.38-45
    • /
    • 1994
  • 계면중합법에 의한 막 제조시 여러 제조변수의 영향을 평가하기 위한 실험을 행하여 다음과 같은 결과를 얻었다. 반응물인 MPD(m-phenylene diamine)농도가 증가할수록 배제율은 증가하나 투과유속은 감소하였다. MPD의 경우에 함침시간이 증가할수록 배제율은 증가하나 투과유속은 감소하였다. TMC(trimesoyl chloride)경우에는 함침시간이 증가할 때 투과유속은 감소한 반면 배제율은 증가한 이후 감소하였다. 열처리 온도가 상승함에 따라 투과유속은 증가하나 배제율은 증가한 이후 감소하였다. 첨가제인 NaOH는 중합시 발생하는 염산의 양이 적어 미량이 중화에 필요하였으며, 그 양이 증가할수록 배제율과 누과유속은 증가한 이후 감소하여\ulcorner. 후처리는 ethanol, isoprophlalcohol, $5~7^{\circ}C$의 물로 치환하여 배제율과 투과유속에서 상승을 가져왔으며, $5~7^{\circ}C$ 물의 경우에는 후처리 시간에 따라 극대값을 가짐을 알 수 있었다.

  • PDF

실험계획법에 의한 메틸염화실란 합성의 최적공정조건 (Optimum Process Condition by Experimental Design Method for the Synthesis of Methylchlorosilanes(MCS))

  • 조철군;한기도
    • 공업화학
    • /
    • 제9권3호
    • /
    • pp.394-398
    • /
    • 1998
  • 실리콘의 모노머로 사용되고 있는 MCS의 합성 최적조건에 관한 연구를 수행하였다. 4원촉매계($CuCl/ZnCl_2/Sn/Cd$)와 원료규소로 부터 접촉물질을 제조한 후, 염화메틸과 반응시켜 MCS를 합성할 때 실험계획법에 따라 실험하고 해석하여 하나의 공정조건을 확립하였다. 접촉물질 50g, 교반속도 60rpm, 상압에서 최적반응온도와 MeCl 유량은 각각 $300-305^{\circ}C$$70-80cm^3/min$이었다. 또한 연속적으로 실험을 수행하여 최적공정조건을 확인하였으며, MeCl의 전환율 67%와 규소소모율 92%에서 평균반응속도는 170(g-MCS/hr.kg-Si), 평균선택도는 0.05이었으며, 연속식 실험결과로부터 총괄반응속도식의 파라미터와 최적압력을 구하였다.

  • PDF

A Review of the Optimum Feeding Rates and Feeding Frequency in Korean Rockfish Sebastes schlegeli Reared at Seven Different Water Temperatures

  • Mizanur, Rahman M.;Bai, Sungchul C.
    • Fisheries and Aquatic Sciences
    • /
    • 제17권2호
    • /
    • pp.229-247
    • /
    • 2014
  • Seven feeding trials were conducted to determine the effects of feeding rate and frequency in the Korean rockfish Sebastes schlegeli at seven different water temperatures. Two feeding-rate experiments for 5-g Korean rockfish at $17^{\circ}C$ and $20^{\circ}C$; three feeding rate experiments for 16-g Korean rockfish at $16^{\circ}C$ and $24^{\circ}C$; and finally, two feeding frequency experiments for 93- and 100-g at $15^{\circ}C$ and $20^{\circ}C$ were conducted. Twenty fish averaging $5.5{\pm}0.2$ g ($mean{\pm}SD$) were randomly distributed into 18 indoor tanks containing 40-L seawater from a semi-recirculation system. Fish were fed a commercial diet for 4 weeks at water temperatures of $17^{\circ}C$ and $20^{\circ}C$. Two feeding trials were conducted to determine the optimum feeding frequency in growing Korean rockfish reared at temperatures of $15^{\circ}C$ and $19^{\circ}C$. Broken line regression analysis of weight gain (WG) indicated that the optimum feeding rates of 5-g growing Korean rockfish were 4.48% (BW/day; BW, body weight) at $17^{\circ}C$ and 4.83% (BW/day) at $20^{\circ}C$. Broken line regression analysis of WG showed optimum feeding rates of 16-g juvenile Korean rockfish of 3.41% (BW/day) at $16^{\circ}C$, 3.75% (BW/day) at $20^{\circ}C$, and 3.34% (BW/day) at $24^{\circ}C$. The biological performance, results, along with morphological indices and serological characteristics, suggest that a feeding frequency of 1 meal/day was optimal to improve WG in growing Korean rockfish grown from 93 to 133 g at a water temperature of $15^{\circ}C$, and 100 to 132 g at $19^{\circ}C$.

강우유출수의 신속한 처리를 위한 고속응집시스템의 성능 평가 -실험실 규모 장치를 중심으로- (Performance Evaluation of Lab-scale High Rate Coagulation System for CSOs Treatment)

  • 권은미;오석진;조성주;이승철;하성룡;임채환;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.629-639
    • /
    • 2010
  • To evaluate the performance of high rate coagulation system(HRCS) for CSOs treatment, fundamental function of lab scale HRCS has been tested by using the Jar tester and lab scale HRCS. The optimum pH dose by Streaming Current value was found in the range of 5.3~6.0 in Fe(III), and in the range of 5.8~6.6 in Al(III) and the optimum chemical dose were 0.44mM of $Al_2(SO_4)_3$ and 0.93mM of $FeCl_3$. The removal efficiencies at optimum $Al_2(SO_4)_3$ dose were 75%($TCOD_{Cr}$), 97%(TP), 95%(SS) and 96%(turbidity), respectively. And the removal efficiency of particles with less than $5{\mu}m$ of diameter was 70% and that of particles with higher than $5{\mu}m$ of diameter was 90%. The optimum alum dose in lab scale HRCS was 150mg/L, and the treatment efficiency was the best with addition of 1.0mg/L polymer. The effect of Micro sand addition was not clear, because the depth of the sediment tank in lab scale HRCS was not long enough. But the HRT of this lab scale HRCS was able to be shorten less then 7 minutes by adding the micro sand. The surface loading rates with respect to using different chemicals were 0.43m/h with alum only, 5.78m/h with alum and polymer and 6.22m/h with alum, polymer and micro sand. As a result, HRCS using coagulant, polymer and micro sand developed in this study was evaluated to be very effective for CSOs treatment.

스테인리스 강 STS305의 디프 드로잉 가공에 관한 실험적 연구 (Experimental study on the severe deep drawing for complex cylindrical housing of STS 305 stainless steel)

  • 김두환
    • 소성∙가공
    • /
    • 제7권5호
    • /
    • pp.439-444
    • /
    • 1998
  • Recently many automotive parts have been made with stainless steels by deep drawing processes, But there are various problems occurred in deep drawing works of stainless steels compared with low carbon steels. For the severe deep drawing of complex cylindrical housing optimum process planning is required to eliminate intermediate annealing improve shape accuracy and maintain surface integrity without drawing defects such as tears wrinkles and scratches or galling. Therefore in this study a sample process planning of the severe of the severe deep drawing process is applied to a complex cylindrical housing needed for a 6 multi-stepped deep drawing of type STS 305 . A series of experiments are performed to investigate optimum process variables such as drawing rate radius and clearance. Through experiments the variations of the thickness strain distribution and hardness distribution in each drawing step are observed. Also the effects of other factors on formability such as drawing oil, blank holding force and die geometry are examined and discussed.

  • PDF

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

Production of red pigments by Monascus purpureus in solid-state culture

  • 박해연;이범규;정욱진
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.315-316
    • /
    • 2001
  • In this study various nutritional and environmental parameters such as, initial moisture content, pH. inoculum size, air rate, sample size and nutrient supplement that influence pigment production were evaluated in solid-state cultures. optimum initial moisture content and pH were determined to be 50% and 6.0, respectively. The supplement of the substrate with different carbon, nitrogen, and mineral source reveals a more inhibitive effect as the substrate concentration increase. optimum aeration rate was determined to be 2vvm in flask culture. The maximum amount of red pigment, 3500 OD/g dried fermented rice, was obtained in optimum conditions which is obtained in solid flask culture.

  • PDF

A Rectangular Fin Optimization Including Comparison Between 1-D and 2-D Analyses

  • Kang, Hyung-Suk
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2203-2208
    • /
    • 2006
  • Both 1-D and 2-D analytic methods are used for a rectangular fin optimization. Optimum heat loss is taken as 98% of the maximum heat loss. Temperature profile using 2-D analytic method and relative error of temperature along the fin length between 1-D and 2-D analytic methods are presented. Increasing rate of the optimum heat loss with the variation of Biot number and decreasing rate of that with the variation of the fin base length are listed. Optimum fin tip length using 2-D analytic method and relative error of that between 1-D and 2-D analytic methods are presented as a function of Biot numbers ratio.

소형선박용 Al-Mg 합금의 해양환경 중 최적 방식 전위결정에 관한 연구 (Investigation on optimum protection potential of Al-Mg alloy for small ship application in sea water solution)

  • 김성종;장석기;김정일;고재용
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.23-24
    • /
    • 2005
  • This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a passive film. In a potentiostatic experiment, the current density after 1200 sec in the potential range of $-0.68{\sim}-1.5 V$ was low. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.5 to -0.7 V(SSCE).

  • PDF