식물세포의 관류배양을 위한 초음파 분리기의 개발

  • Gu, Yeong-Han;Jo, Gyu-Heon
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.402-404
    • /
    • 2000
  • In this study, we have developed an ultrasonic separation system for plant cells and its operating conditions in terms of voltage, flow rate and concentration were examined. For plant cell, the operation of ultrasonic separator highly depended on concentration of cells. Holding capacity highly depended on flow rate in chamber. Optimum voltage was 30V in high density culture

  • PDF

Solid-liquid Interface Shape in LiF Single Crystal Growth (LiF 단결정 성장에서 고체-액체의 계면형상)

  • 정대식;오근호
    • Journal of the Korean Ceramic Society
    • /
    • v.21 no.3
    • /
    • pp.271-277
    • /
    • 1984
  • To study interface between crystals grown and molten state in the crusible. Pulling and rotating rate of the shaft were varied in LiF crystal growth by Czochralski method. Lower speed of the pulling and rotating rate increased the degree of convexity in solid-liquid interface and higher speed of the pulling and rotating rate decreased it. Optimum condition of LiF crystal growth obtained as pulling rate was 6.5cm/h when it rotated as 46rpm.

  • PDF

A Study on the Protection Method of Mine Site Slope Using Mine Green Framework (식생 방틀공법을 이용한 광산사면 보호공법에 관한 연구)

  • Choi, Gwang-Su;Kim, Tae-Heok;Kwon, Hyun-Ho
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.526-533
    • /
    • 2009
  • This study presents Mine Green Framework(M.G.F) which can protect the slope of rock and tailings. M.G.F method provides the fiber frame which helps the growth of the plant in the barren site like mined rock slope. M.G.F system consists of the polyester fiber mat, soil, seeds and anchors for the attachment. The optimum rate of filling materials was figured out by many germination tests in order to improve the effect of filling materials and the optimum rate of filling materials was applied in four test sites individually. High rooting rate over 70% was confirmed in all field tests. Especially the moisturizer was the most important component of filling materials and it could make the better condition for the plants.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

Optimum Conditions for Removal of Hydrogen Sulfide Using Fe-EDTA Complex (Fe-EDTA 착물을 이용한 황화수소 제거의 최적 반응 조건)

  • Jin, Sang-Gi;Cha, Jin-Myeong;Lee, In-Wha;Yoon, Suk-Jin;Kim, Si-Wouk
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.177-185
    • /
    • 1996
  • The optimum conditions for the removal of hydrogen sulfide by Fe-EDTA complex in the bubble column reactor were investigated. As the concentrations of the complex increased, the conversion rate of hydrogen sulfide increased, while Fe concentration and pH were stably decreased and the amount of elemental sulfur produced was also increased. Hydrogen sulfide was removed efficiently when the concentration of Fe-EDTA complex was maintained more than 0.05M. pH acts as an important factor for the stability of complex in the oxidation of hydrogen sulfide and optimum pH range was 8.5~9.5. As the molar ratio of EDTA : Fe was increased, the conversion rate of hydrogen sulfide became stable. However, the rate was decreased due to the precipitation of FeS when the concentration of EDTA was decreased. As the concentration of EDTA increased, the conversion rate of hydrogen sulfide increased due to the high stability of Fe-EDTA complex.

  • PDF

Optimum Harvest Time for High Quality Seed Production of Sweet and Super Sweet Corn Hybrids

  • Lee Suk Soon;Yun Sang Hee;Seo Jung Moon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • The production of sweet (su) and super sweet corns (sh2) has been economically feasible in Korea in recent years. Major factors limiting super sweet corn production are low germination and low seedling vigor. Since seed quality is closely related to seed maturity, the optimum harvest time for the seed production of sweet and super sweet corns was studied and the quality of seeds with varying maturities was investigated in 2001 and 2002 cropping seasons. The parents of the sweet corn seeds were Hybrid Early Sunglow and 'Golden Cross Bantam 70' and those of super sweet corn were Xtrasweet 82 and 'For­tune'. Seeds were harvested at 21, 28, 35, 42, 49, and 56 days after silking (DAS). As the seeds developed, seed weight of sweet corn increased and the seed moisture content decreased faster than that of super sweet corn. Germination rates of sweet corn seeds harvested 21 and 28 DAS at $25^{\circ}C$ and emergence rates in the cold soil test were significantly lower than those of seeds harvested after 42 DAS in both years. Although the germination rates of super sweet corn seeds with varying maturities showed similar patterns as sweet corn seeds at $25^{\circ}C$, the emergence rate of super sweet corn seeds in cold soil test continuously increased with seed maturity. This suggests that seed quality of super sweet corn should be tested in a cold soil test to estimate field emergence. As the seeds developed, leakage of total sugars and electrolytes from the both sweet and super sweet corn seeds decreased up to 42 or 49 DAS. The $\alpha-amylase$ activities of both sweet and super sweet corn seeds increased with seed maturity from 21 to 35 or 49 DAS depending on genotype and year. The optimum harvest time for the seed production of sweet corn was 42 DAS and 49 DAS for super sweet corn considering emergence rate and plumule dry weight in the cold soil test, leakage of sugars and electrolytes from the seeds, and $\alpha-amylase$ activity.

Effects of Operating Parameters on Electrochemical Degradation of Rhodamine B and Formation of OH Radical Using BDD Electrode (BDD 전극을 이용한 OH 라디칼 생성과 염료 분해에 미치는 운전인자의 영향)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1143-1152
    • /
    • 2010
  • The purpose of this study is to degradation of Rhodamine B (RhB, dye) and N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the electro-generation of OH radical) in solution using boron doped diamond (BDD) electrode. The effects of applied current (0.2~1.0 A), electrolyte type (NaCl, KCl, and $Na_2SO_4$) and electrolyte concentration (0.5~3.0 g/L), solution pH (3~11) and air flow rate (0~4 L/min) were evaluated. Experimental results showed that RhB and RNO removal tendencies appeared with the almost similar thing, except of current. Optimum current for RhB degradation was 0.6 A, however, RNO degradations was increased with increase of applied current. The RhB and RNO degradation of Cl type electrolyte were higher than that of the sulfate type. The RhB and RNO degradation were increased with increase of NaCl concentration and optimum NaCl dosage was 2.5 g/L. The RhB and RNO concentrations were not influenced by pH under pH 7. Optimum air flow rate for the oxidants generation and RhB and RNO degradation were 2 L/min. Initial removal rate of electrolysis process was expressed Langmuir - Hinshelwood equation, which is used to express the initial removal rate of UV/$TiO_$2 process.

Development of a Hot Water Boiler System with a Rice Hull Furnace (왕겨 연소기(燃燒機)를 이용(利用)한 온수(溫水)보일러 시스템 개발(開發) (I) -실험적(實驗的) 연구(硏究)-)

  • Lee, Y.K.;Park, S.J.;Baek, P.K.;Noh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.4
    • /
    • pp.31-43
    • /
    • 1987
  • This study was performed to develop a hot water boiler system with small scale automatic rice hull furnace for the multi-purpose use in the farm. For the experiment a prototype hot water boiler system with rice hull furnace was fabricated, which was equipped with automatic hull feeder, igniter and ash removal device. Optimum operational conditions of the prototype: system were analyzed. The results arc summarized as follows. 1. The temperature measured right above the burning surface should be higher than $500^{\circ}C$ combustion. 2. The top zone of the combustion chamber was the most suitable location of the thermocouple to pick up the control temperature for the automatic operation of the rice hull furnace. 3. The content of carbon monoxide in the flue gas was increased with the filling height of burning material but it was less than 0.3 percent in volume in this experiment. When the filling height was expressed as the ratio of rice hull feed rate to the volume of the combustion chamber above the burning surface, the optimum ratio was about $150kg/m^3-h$. 4. The combustion efficiency of the prototype was higher than 95 percent when the feed rate was 1.1 to 2.3 kg/h and moisture content of rice hull was 22.4 percent (w.b.) or less. 5. It was estimated that the optimum operational conditions of the system were 1.3 to 2.0 kg/h in feed rate, 70 to 100 percent in excess air and 500 to $510^{\circ}C$ in control temperature. 6. The efficiency of coil heal exchanger increased with a decrease in feed rate of rice hull. When the rice hull feed rates were 1.1, 1.7 and 2.3 kg/h, the efficiencies of coil heat exchanger were about 34, 30 and 25 percent and heat transfer rates were 5.7, 7.6 and 8.8 MJ/h, respectively. When the flat plate heat exchanger was used in addition to the coil heat exchanger, the efficiency of the heat exchanger system increased to 48 percent.

  • PDF

Evaluation of Optimum Mixing Rate and Durability of Concrete Using Water Granulated Slag Fine Aggregate (수쇄 페로니켈슬래그 잔골재를 이용한 콘크리트의 최적 혼합률 및 내구 특성 평가)

  • Choi, Yun-Wang;Park, Man-Seok;Lee, Kwang-Myong;Bae, Su-Ho;Kim, Jee-Sang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.120-127
    • /
    • 2011
  • Recently, there are problems due to the exhaustion of natural aggregate resources, and strict restrictions. In this study, the possibility of using Water Granulated Ferro-Nickel slag as a substitutive material of fine aggregate is determined from the properties of mechanical and durability for the concrete that is made with Water Granulated Ferro-Nickel slag. According to the test results, when the mixing rate of Water Granulated Ferro-Nickel Slag aggregates concrete is adjusted, up to 50% of its aggregates by mixing rate can be mixed with general aggregates. The optimum mix ratio is considered to be 40%. The freezing and thawing resistance of Water Granulated Ferro-Nickel Slag aggregates concrete is identical to that of general aggregates concrete, while the carbonation resistance is found to be same as or lower than that of general aggregates concretes.

  • PDF

Numerical Study on the Flow Characteristics of Flat-Plate Solar Collector with Riser Number (평판형 집열기의 지관수에 따른 유동특성에 대한 수치해석 연구)

  • Kim, Jeong-Bae;Lee, Dong-Won;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.143-148
    • /
    • 2007
  • It is essential to know the flow characteristics at the risers of Flat-plate solar collector for optimum design. For flat-plate solar collector, it is difficult to experimentally study the effect for the number of riser in the collector for the economic problem. So, this study was performed to show the flow characteristics of flat-plate solar collector with the number of riser using commercial code FLUENT 6.0. The base collector size is chosen with $2\;m^2$ as 1m by 2m in this study, the mass flow rate was estimated 0.04 kg/s using the mass flow rate of 0.02 kg/s per collector area for the certificate test. The number of riser is selected 4, 6, 8, 10, 12, and 14. Through the simulation, the conditions with the risers of 10 or 12 is shown as the optimum design conditions for conventional flat-plate solar collector considering lower pressure drop and more uniformly distributed mass flow rate for higher heat transfer rate without considering heat transfer.