• 제목/요약/키워드: Optimum Sensor Location

검색결과 30건 처리시간 0.026초

Optimum control system for earthquake-excited building structures with minimal number of actuators and sensors

  • He, Jia;Xu, You-Lin;Zhang, Chao-Dong;Zhang, Xiao-Hua
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.981-1002
    • /
    • 2015
  • For vibration control of civil structures, especially large civil structures, one of the important issues is how to place a minimal number of actuators and sensors at their respective optimal locations to achieve the predetermined control performance. In this paper, a methodology is presented for the determination of the minimal number and optimal location of actuators and sensors for vibration control of building structures under earthquake excitation. In the proposed methodology, the number and location of the actuators are first determined in terms of the sequence of performance index increments and the predetermined control performance. A multi-scale response reconstruction method is then extended to the controlled building structure for the determination of the minimal number and optimal placement of sensors with the objective that the reconstructed structural responses can be used as feedbacks for the vibration control while the predetermined control performance can be maintained. The feasibility and accuracy of the proposed methodology are finally investigated numerically through a 20-story shear building structure under the El-Centro ground excitation and the Kobe ground excitation. The numerical results show that with the limited number of sensors and actuators at their optimal locations, the predetermined control performance of the building structure can be achieved.

Measurement Level Experimental Test Result of GNSS/IMU Sensors in Commercial Smartphones

  • Lee, Subin;Ji, Gun-Hoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권3호
    • /
    • pp.273-284
    • /
    • 2020
  • The performance of Global Navigation Satellite System (GNSS) chipset and Inertial Measurement Unit (IMU) sensors embedded in smartphones for location-based services (LBS) is limited due to the economic reasons for their mass production. Therefore, it is necessary to efficiently process the output data of the smartphone's embedded sensors in order to derive the optimum navigation values and, as a previous step, output performance of smartphone embedded sensors needs to be verified. This paper analyzes the navigation performance of such devices by processing the raw measurements data output from smartphones. For this, up-to-dated versions of smartphones provided by Samsung (Galaxy s10e) and Xiaomi (Mi 8) are used in the test experiment to compare their performances and characteristics. The GNSS and IMU data are extracted and saved by using an open market application software (Geo++ RINEX Logger & Mobile MATLAB), and then analyzed in post-processing manner. For GNSS chipset, data is extracted from static environments and verified the position, Carrier-to-Noise (C/N0), Radio Frequency Interference (RFI) performance. For IMU sensor, the validity of navigation and various location-based-services is predicted by extracting, storing and analyzing data in static and dynamic environments.

CFD 해석을 이용한 실내 온도 최적 측정 위치 선정 방법 (Optimal Measuring Point Selection Method of Indoor Temperature using CFD Analysis)

  • 이민구;정경권
    • 한국정보통신학회논문지
    • /
    • 제16권7호
    • /
    • pp.1559-1566
    • /
    • 2012
  • 본 논문에서는 실거주 환경과 같이 구축된 테스트베드에 온도 센서를 설치하여 최적의 온도 측정 위치를 설정하는 방법을 제안한다. 테스트베드를 CFD(Computational Fluid Dynamics) 방법으로 온도 변화를 시뮬레이션하고, 온도 변화와 기류 변화를 확인하여 최적 온도 측정 위치를 선정한다. 디자인빌더 소프트웨어를 이용하여 테스트베드를 3차원 모델링을 하고 CFD를 실행하였다. 최적위치는 바닥에서 높이 1.5m이고, 온도 변화가 적은 곳을 선택하였다. 실제 공간에 30개의 온습도센서를 설치하여 실험을 진행하였고 온도변화 결과를 확인하였다.

2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구 (Experiments for the Acoustic Source Localization in 2D Cavity Flow)

  • 이재형;박규철;최종수
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명 (Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array)

  • 이재형;최종수;박규철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF

원격탐지기능을 갖는 무선부표시스템 (Wireless Buoy System with Remote Sensing and Access Capability)

  • 권원현
    • 한국통신학회논문지
    • /
    • 제36권5B호
    • /
    • pp.549-556
    • /
    • 2011
  • 본 연구에서는 기존의 우선 부표가 지니고 있는 문제점들을 해결할 수 있는 원근해 어로용 고성능 무선 부표 시스템을 개발하였다. 2진 FSK 변조방식과 우선부표용 송수신 프로토콜을 도입하여 사용시간을 대폭 개선하였으며, GPS 위치정보와 여러 계측정보를 수집한 후 모선의 탐지기 호출이 있을 경우 전송함으로써 쉽게 탐색이 이루어질 수 있도록 하였다. 개발된 우선부표는 평균 73일의 동작시간과 120km 이상의 동작시간과 120km 이상의 동작범위를 갖으며, 분실과 도난을 방지할 수 있다.

The Effect of Exhaust Gas Recirculation (EGR) on Combustion Stability, Engine Performance and Exhaust Emissions In a Gasoline Engine

  • Jinyoung Cha;Junhong Kwon;Youngjin Cho;Park, Simsoo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권10호
    • /
    • pp.1442-1450
    • /
    • 2001
  • The EGR system has been widely used to reduce nitrogen oxides (NO$\_$x/) emission, to improve fuel economy and suppress knock by using the characteristics of charge dilution. However, as the EGR rate at a given engine operating condition increases, the combustion instability increases. The combustion instability increases cyclic variations resulting in the deterioration of engine performance and emissions. Therefore, the optimum EGR rate should be carefully determined in order to obtain the better engine performance and emissions. An experimental study has been performed to investigate the effects of EGR on combustion stability, engine performance,70x and the other exhaust emissions from 1.5 liter gasoline engine. Operating conditions are selected from the test result of the high speed and high acceleration region of SFTP mode which generates more NO$\_$x/ and needs higher engine speed compared to FTP-75 (Federal Test Procedure) mode. Engine power, fuel consumption and exhaust emissions are measured with various EGR rate. Combustion stability is analyzed by examining the variation of indicated mean effective pressure (COV$\_$imep/) and the timings of maximum pressure (P$\_$max/) location using pressure sensor. Engine performance is analyzed by investigating engine power and maximum cylinder pressure and brake specific fuel consumption (BSFC)

  • PDF

점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향 (Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition)

  • 김철수;이근후
    • 한국농공학회지
    • /
    • 제31권2호
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

호흡주기에 따른 방사선입체조형치료법의 개발 (Development of Conformal Radiotherapy with Respiratory Gate Device)

  • 추성실;조광환;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 목적 : 호흡주기에 따른 위치변동 감지센서를 이용하여 종양의 위치가 일정워치에 있을 때만 방사선을 치료하는 호흡 동기치료기구를 제작하고 일정한 호흡주기 상태에서 수행된 CT simulation과 3차원 입체조형치료계획에 따라 방사선을 치료하는 시스템을 개발하고자 하였다. 호흡유무에 따른 종양의 치료 마진(margin)을 측정하고 계획용표적체적(planning target volume:PTV)의 크기에 따른 선량체적표(dose volume histogram:DVH)와 종양억제확률(tumor control probability:NTCP), 건강조직손상확률(normal tissue complication probability:NTCP) 및 선량 통계자료를 통하여 치료성과를 평가하고 선량증강 범위를 예측하고자 하였다. 대상 및 방법 : 종양이 비교적 작고 전이가 없는(T1N0M0) 5명의 폐암환자를 선택하여 X-선 조준장치를 이용하여 횡격막의 이동거리를 측정하는 방법으로 내부장기의 운동을 평가하였다. 호흡동기치료기구는 끌어당김 센서가 부착된 허리띠 모양으로 구성되었으며 이를 흉곽 또는 복부에 부착하여 호흡주기에 의한 흉곽의 크기변동에 따라 센서의 회로가 개폐되고 이것을 선형가속기의 조종간에 연결하는 간단한 기구로서 감도와 재현성이 높았다. 호흡을 배기한 후 일시적 호흡이 정지된 상태에서 Spiral-CT (PQ-5000)로 3차원 영상을 획득하고 Virtual CT-simulator (AcQ-SIM)에 의하여 종양의 위치와 주위 장기들을 확인 도시하였으며 3차원 치료계획장치(Pinnacle, ADAC Co.)를 이용하여 3차원 입체조형치료를 계획하였다. 치료계획의 평가는 호흡동기치료기구의 사용유무에 따른 PTV의 크기에 따라 최적 선량분포를 구사하였으며 각각의 DVH, TCP, NTCP 및 선량통계자료를 도출 비교 검토하였다. 결과 : X-선 simulation에서 폐암환자의 횡격막 이동은 약 1 cm에서 2.5 cm로서 평균 1.5 cm로 측정되었고 자유호흡시 PTV는 CTV (clinical target volume)에 약 2 cm 마진을 주었으며 호흡동기치료기구를 사용하였을 때는 0.5 cm 마진이 적당한 것으로 측정되었다. 종양의 PTV는 연장 마진의 거의 자승비로 증가하였으며 TCP의 값은 마진 범위 $(0.5\~2.0\;cm)$에 관계없이 거의 일정하였고 NTCP의 값은 마진 크기에 따라 평균 $65\%$로 급속히 증가하였다. 결론 : 호흡주기에 따른 위치변동 감지센서를 이용한 호흡동기치료기구는 종양의 위치가 일정할 때만 방사선이 조사되는 간단하고 정확한 장치로서 3차원 입체조형치료 및 강도변조방사선치료에서 매우 유용한 장치임을 확인할 수 있었다. 또한 호흡조절 방사선입체조형치료방법의 기술과 시술절차를 확립시키고 정량적인 선량평가를 위하여 DVH, TCP, NTCP 등의 정량분석과 종양의 투여 선량 증가량(dose escalation)을 예측하는 기초자료를 제공할 수 있었다.