• 제목/요약/키워드: Optimum Reynolds Number

검색결과 76건 처리시간 0.029초

Effects of Hub-to-Tip Ratio and Reynolds Number on the Performance of Impulse Turbine for Wave Energy Power Plant

  • Ajit Thakker;Khaleeq, Hammad-Bin;Manabu Takao;Toshiaki Setoguchi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1767-1774
    • /
    • 2003
  • The objective of this paper is to present the performance comparison of the impulse turbines for different diameters. In the study, the investigation has been performed experimentally by model testing for some diameters, especially 0.3 m and 0.6 m. The experiment was performed for Reynolds number range of 0.17 ${\times}$ 10$\^$5/ -1.09 ${\times}$ 10$\^$5/ and for different values of hub-to-tip ratio ν ranging from 0.6 to 0.85. As a result, it was found that the critical Reynolds number is to be around 0.5 ${\times}$ 10$\^$5/ for ν=0.6 and 0.4 ${\times}$ 10$\^$5/ for ν=0.7. For the hub-to-tip ratio, the optimum value is 0.7 when the turbine is operated at lower Reynolds number. However, its value seems to be 0.6 at higher Reynolds number in the tested range.

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

주름형상 판형열교환기 채녈에서의 열전달 특성 수치해석적 연구 (Numerical Analysis of Heat Transfer Characteristics in Corrugated Plate Type Heat Exchanger Channel)

  • 김태용;이재용;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.588-594
    • /
    • 2001
  • The purpose of this study is to investigate the thermal and hydrodynamic characteristics of the channel in corrugated plate type heat exchangers numerically. Numerical work has been conducted using the Reynolds Stress Model(RSM) by utilizing the commercial finite-volume code, FLUENT. Based on this model, the dependence of heat transfer and friction factor on geometrical parameters have been investigated. It is found that larger corrugation angle give higher values of heat transfer coefficients and friction factors. As the reynolds number increases, the heat transfer coefficient also increases. It is also observed that the heat transfer coefficient reaches maximum while the friction factor stays relatively low at same corrugation angle. Through the analysis, it is found that the optimum corrugation angle for the heat exchanger performance exists. It is noted that the flow repulsions at the contact point of the two fluid streams make the low mixing more active for larger corrugation angle and high reynolds number.

  • PDF

노즐-디류저 내에서의 저 Reynolds수 해독특성 해석 (Analysis of Low Reynolds Number Flow in Nozzle and Diffuser)

  • 송귀은;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2672-2677
    • /
    • 2007
  • An investigation of low Reynolds number flow in nozzles and diffusers which are widely used in the valveless micropump is presented. Flow characteristics in the nozzle and diffuser are explained in view of viscous effect and flow oscillation induced by pumping membrane. These calculation results show that the rectification property of valveless micropump is due to a flow separation in the diffuser and the separation is largely originated from the flow oscillation. Under the assumptions of steady flow velocity profile and flow separation in the diffuser, simplified analytical models are provided to see the dependency of rectification on the micropump geometry. Geometric parameters of channel length, nozzle throat, chamber size, and converging/diverging angle are depicted through the analytical models in low Reynolds number flow, and the prediction and experimental results are compared. This theoretical study can be used to determine the optimum geometry of valveless micropump.

  • PDF

3차원 날개 설계를 위한 저레이놀즈수 에어포일에 대한 연구 (A STUDY ON THE LOW REYNOLDS NUMBER AIRFOILS FOR THE DESIGN OF THREE DIMENSIONAL WING)

  • 정경진;이재훈;권장혁;강인모
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.90-96
    • /
    • 2009
  • In this study, a generic airfoil designed by the inverse method was evaluated with several candidate airfoils as a first step. Each airfoil was compared with respect to aerodynamic performance to meet the requirement of HALE(high altitude long endurance) aircraft. The second step was to optimize the candidate airfoil using the couple of optimization formulations to down select an optimum airfoil. For the analysis of low Reynolds number 2D flow, Drela's MSES was used. After comparing the aerodynamic results, the best airfoil was chosen to construct the baseline 3D wing. The Navier-Stokes code was used to evaluate the overall aerodynamic performance of designed wing with other wings. The results show that the designed wing has the best performance compared with other wings.

  • PDF

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

수직으로 엇갈린 등온평판에서의 혼합대류 열전도 (Mixed Convection Heat Transfer from Vertically Misaligned Isothermal plates)

  • 권순석;김상영;박순업
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.52-61
    • /
    • 1992
  • The steady laminar mixed convection from vertically misaligned, isothermal plastes has been studied by numerical procedure. The governing equations are solved by the finite difference method using successive using successive over relaxation scheme at Re=100-800, $Gr=10^3-10^6$, Pr=0.71 and dimensionless plate spacings b/L=0.1-1.0. The plume interaction caused by the thermal interference of twoplates is observed. As Reynolds numbers increase, the optimum plate spacings are moved to narrow spacings at the same Grashof number and as Grashof numbers increase, to wide spacings at the same Reynolds number.

  • PDF

장방형 충돌수분류 냉각계의 국소열전달에 관한 연구 (A study on the local heat transfer in rectangular impinging water jet cooling system)

  • 이종수;엄기찬;최국광
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1395-1405
    • /
    • 1996
  • The purpose of this experimental research is to investigate the local heat transfer characteristics in the upward free water jet impinged on a downward flat plate of uniform heat flux. The inner shape of rectangular nozzle used was sine curve type and its contraction ratio of inlet to outlet area was five. Experimental parameters considered were Reynolds number, nozzle exit-flat plate distance, and level of supplementary water. Local Nusselt number was influenced by Reynolds number, Prandtl number, supplementary water level, and distance between the nozzle exit and flat plate. Within the impingement region, the Nusselt number has a maximum value on the nozzle center axis and decreases monotonically outward from center. Outside of the impingement region, on the other hand, the Nusselt number has a secondary peak near the position where the distance from nozzle center reaches four times the nozzle width. However if nozzle exit velocity exceeds 6.2 m/s, the secondary peak appears also in the impingement region. The empirical equation for the stagnation heat transfer is a function of Prandtl, Reynolds, and axial distance from the nozzle exit. The optimum level of supplementary water to augment the heat transfer rate at stagnation point was found to be twice the nozzle width.

마이크로 유동에서 플래핑 날개의 Tandem 모드를 이용한 추력향상에 대한 연구 (Thrust Enhancement through a Tandem Mode of Flapping Wing in Micro Flow)

  • 장성민;맹주성;안상준
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.605-611
    • /
    • 2011
  • In this study, based on previous studies, the thrust generated by using flapping tandem wings is examined. We studied on the relationship between the parameters for characterizing oscillatory tandem wings (namely, the Strouhal number and Reynolds number) for thrust generation in micro flow regime. At each Reynolds number, Strouhal number, heaving amplitude, distance between tandem wings, and phase difference are varied and the flapping motions of tandem mode are calculated to find the optimum conditions for generating thrust. As a result, comparing with a single flapping mode, we found that the minimum Strouhal number for generating thrust is shifted down up to approximately 25% when the tandem flapping mode is applied.

Hot Cell 내에 오염된 고방사능분진 제거를 위한 사이클론 개발 및 성능평가 (The Development and Performance Evaluation of a Cyclone to Remove Hot Particulate from a Contaminated Hot Cell)

  • 김계남;원휘준;최왕규;정종헌;오원진;박진호
    • 방사성폐기물학회지
    • /
    • 제4권3호
    • /
    • pp.217-226
    • /
    • 2006
  • 원자력연구소 핫셀의 구조와 오염특성이 조사되었다. SEM 측정결과 핫셀 내부에 부착된 고방사능 분진의 크기는 $0.2{\sim}10{\mu}m$이었다. 사이클론의 최적 Vortex finder의 길이는 49 mm이고, 모의입자 유입속도는 15m/sec가 적합했다. 이때 $3{\mu}m$의 포집효율은 약 85%였다. 모의 입자 유입속도가 15m/sec보다 빠를 때, 포집효율의 증가율은 크지 않았다. 유입가스의 온도가 증가할 때, 포집효율은 약간 감소했다. Vortex finder의 길이가 증가할수록 사이클론내의 압력강하는 커졌다. Cut size diameter는 Reynolds number의 증가와 함께 감소했다. 측정된 Reynolds number에 근거하면, 사이클론 내부는 난류이고 이 난류는 사이클론 내의 압력강하에 원인이 된다고 사료된다. $Stk^{1/2}_{50}$는 Re 값의 증가와 함께 감소하고, Re의 값이 커질 때에서 일정한 값에 수렴했다. 즉, 6000-8000의 Re에서 $Stk^{1/2}_{50}$는 약 0.045를 나타냈다.

  • PDF