• Title/Summary/Keyword: Optimized protocol

Search Result 268, Processing Time 0.032 seconds

Improvement of High Permittivity Pads for Areas with Generally Low Signal Sensitivity at 7T MRI (7T MRI에서 일반적으로 신호 감도가 낮은 영역에 대한 고유전율 패드 개선)

  • Yong-Tae, Kim;Hyeon-Man, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.761-769
    • /
    • 2022
  • Pads with high dielectric materials have been used in a variety of applications to locally improve the field sensitivity and homogeneity of RF pulses in clinical MRI studies. In this study, we aimed to improve such pads in consideration of the practical problems associated with the application of actual clinical images. A high permittivity pad to increase the attenuated B1 field strength was fabricated and tested in 7T MRI. Sim4Life simulation and experimental results show stronger and relatively uniform B1 near field. In order to improve the image quality in the whole cerebellum, known as a region with low sensitivity, a guide was made to reduce the mechanical change of the pad. In order to improve the wearing comfort, the pad was designed by dividing it into upper and lower parts. The facial pad showed an overall signal increase effect in areas such as the turbinate in the nasal cavity. Signal increase was expected in areas such as the frontal lobe and eyes, but the effect was either insignificant or it was difficult to see the effect in the imaging protocol. In conclusion, this paper showed a cerebellar-optimized pad with an improved nasal signal while maintaining its effectiveness.

Efficient Privacy-Preserving Duplicate Elimination in Edge Computing Environment Based on Trusted Execution Environment (신뢰실행환경기반 엣지컴퓨팅 환경에서의 암호문에 대한 효율적 프라이버시 보존 데이터 중복제거)

  • Koo, Dongyoung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.305-316
    • /
    • 2022
  • With the flood of digital data owing to the Internet of Things and big data, cloud service providers that process and store vast amount of data from multiple users can apply duplicate data elimination technique for efficient data management. The user experience can be improved as the notion of edge computing paradigm is introduced as an extension of the cloud computing to improve problems such as network congestion to a central cloud server and reduced computational efficiency. However, the addition of a new edge device that is not entirely reliable in the edge computing may cause increase in the computational complexity for additional cryptographic operations to preserve data privacy in duplicate identification and elimination process. In this paper, we propose an efficiency-improved duplicate data elimination protocol while preserving data privacy with an optimized user-edge-cloud communication framework by utilizing a trusted execution environment. Direct sharing of secret information between the user and the central cloud server can minimize the computational complexity in edge devices and enables the use of efficient encryption algorithms at the side of cloud service providers. Users also improve the user experience by offloading data to edge devices, enabling duplicate elimination and independent activity. Through experiments, efficiency of the proposed scheme has been analyzed such as up to 78x improvements in computation during data outsourcing process compared to the previous study which does not exploit trusted execution environment in edge computing architecture.

AutoML Machine Learning-Based for Detecting Qshing Attacks Malicious URL Classification Technology Research and Service Implementation (큐싱 공격 탐지를 위한 AutoML 머신러닝 기반 악성 URL 분류 기술 연구 및 서비스 구현)

  • Dong-Young Kim;Gi-Seong Hwang
    • Smart Media Journal
    • /
    • v.13 no.6
    • /
    • pp.9-15
    • /
    • 2024
  • In recent trends, there has been an increase in 'Qshing' attacks, a hybrid form of phishing that exploits fake QR (Quick Response) codes impersonating government agencies to steal personal and financial information. Particularly, this attack method is characterized by its stealthiness, as victims can be redirected to phishing pages or led to download malicious software simply by scanning a QR code, making it difficult for them to realize they have been targeted. In this paper, we have developed a classification technique utilizing machine learning algorithms to identify the maliciousness of URLs embedded in QR codes, and we have explored ways to integrate this with existing QR code readers. To this end, we constructed a dataset from 128,587 malicious URLs and 428,102 benign URLs, extracting 35 different features such as protocol and parameters, and used AutoML to identify the optimal algorithm and hyperparameters, achieving an accuracy of approximately 87.37%. Following this, we designed the integration of the trained classification model with existing QR code readers to implement a service capable of countering Qshing attacks. In conclusion, our findings confirm that deriving an optimized algorithm for classifying malicious URLs in QR codes and integrating it with existing QR code readers presents a viable solution to combat Qshing attacks.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.

Determination of Petroleum Aromatic Hydrocarbons in Seawater Using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography/Mass Spectrometry (HS-SPME-GC/MS를 이용한 해수 내 유류계 방향족탄화수소 분석법)

  • An, Joon Geon;Shim, Won Joon;Ha, Sung Yong;Yim, Un Hyuk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2014
  • The headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/mass spectrometry procedure has been developed for the simultaneous determination of petroleum aromatic hydrocarbons such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) and polycyclic aromatic hydrocarbons (PAHs) in seawater. The advantages of SPME compared to traditional methods of sample preparation are ease of operation, reuse of fiber, portable system, minimal contamination and loss of the sample during transport and storage. SPME fiber, extraction time, temperature, stirring speed, and GC desorption time were key extraction parameters considered in this study. Among three kinds of SPME fibers, i.e., PDMS ($100{\mu}m$), CAR/PDMS ($75{\mu}m$), and PDMS/DVB ($65{\mu}m$), a $65{\mu}m$ PDMS/DVB fiber showed the most optimal extraction efficiencies covering molecular weight ranging from 78 to 202. Other extraction parameters were set up using $65{\mu}m$ PDMS/DVB. The final optimized extraction conditions were extraction time (60 min), extraction temperature (50), stirring speed (750 rpm) and GC desorption time (3 min). When applied to artificially contaminated seawater like water accommodated fraction, our optimized HS-SPME-GC/MS showed comparable performances with other conventional method. The proposed protocol can be an attractive alternative to analysis of BTEX and PAHs in seawater.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

The morphological characteristics and fatty acids composition of pollens in acorn and darae(Actinidia arguta) (도토리화분과 다래화분의 일반성분, 지방산 분석 및 형태 관찰)

  • Hong, In-Pyo;Lee, Man-Young;Woo, Soon-Ok;Sim, Ha-Sik;Choi, Yong-Soo;Han, Sang-Mi;Kim, Hye-Kyung;Byeon, Kyu-Ho;Lee, Myeong-Lyeol;Kim, Jung-Bong
    • Journal of Sericultural and Entomological Science
    • /
    • v.51 no.2
    • /
    • pp.119-122
    • /
    • 2013
  • Pollens have been known to possess various biological properties. Therefore, pollens have been extensively used in functional food, folk medicine, and beverage industry to improve human health. This study was conducted to establish the optimized protocol for cytoplasm isolation of bee pollen. Data of biochemical parameters and fatty acid profiles were obtained from pollens of Acorn and Darae(Actinidia arguta). Contents of crude protein and crude fat were 24.1% and 11.8% in Acorn pollen, and those of Darae pollen showed 35.8% and 8.7% in crude protein and crude fat respectively. Also after lyophilizing of Acorn pollen, content of crude protein was increased to 26.5%. Main fatty acids were palmitic acid(C16 : 0), oleic acid(C18 : 1), linoleic acid(C18 : 2) and linolenic acid(C18 : 3) in bee pollen. Linoleic acid(37.3%) was dominant fatty acid in Acorn pollen that is one of essential fatty acids. Linolenic acid(48.3%) was dominant fatty acid in Darae pollen that is a polyunsaturated fatty acid. The proportion of unsaturated fatty acids to total acid content was 73.2% in Acorn and 63.2% in Darae pollen, and especially that of polyunsaturated fatty acids was higher than 55%.

Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease (폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성)

  • Park, Hoon-Hee;Roh, Dong-Wook;Kim, Sei-Young;Rae, Dong-Kyeong;Lee, Min-Hye;Kang, Chun-Goo;Lim, Han-Sang;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Purpose: The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomograhpy ($^{18}F-FDG $PET) for the non-invasive differentiation of focal lung lesions originated from cancer or inflammation disease by combined visual image interpretation and semi-quantitative uptake value analysis has been documented. In general, Standardized Uptake Value(SUV) is used to diagnose lung disease. But SUV does not contain dynamic information of lung tissue for the glucose. Therefore, this study was undertaken to hypothesis that analysis of dynamic kinetics of focal lung lesions base on $^{18}F-FDG$ PET may more accurately determine the lung disease. So we compared Time Activity Curve(TAC), Standardized Uptake Value-Dynamic Curve(SUV-DC) graph pattern with Glucose Metabolic Rate(MRGlu) from Patlak analysis. Methods: With lung disease, 17 patients were examined. They were injected with $^{18}F-FDG$ over 30-s into peripheral vein while acquisition of the serial transaxial tomographic images were started. For acquisition protocol, we used twelve 10-s, four 30-s, sixteen 60-s, five 300-s and one 900-s frame for 60 mins. Its images were analyzed by visual interpretation TAC, SUV-DC and a kinetic analysis(Patlak analysis). The latter was based on region of interest(ROIs) which were drawn with the lung disease shape. Each optimized patterns were compared with itself. Results: In TAC patterns, it hard to observe cancer type with inflammation disease in early pool blood area but over the time cancer type slope more remarkably increased than inflammation disease. SUV-DC was similar to TAC pattern. In the result of Patlak analysis, In time activity curve of aorta, even though inflammation disease showed higher blood activity than cancer, at first as time went by, blood activity of inflammation disease became the lowest. However, in time activity curve of tissue, cancer had the highest uptake and inflammation disease was in the middle. Conclusion: Through the examination, TAC and SUV-DC could approached the results that lung cancer type and inflammation disease type has it's own difference shape patterns. Also, it has outstanding differentiation between cancer type and inflammation in Patlak and MRGlu analysis. Through these analysis methods, it will helpful to separation lung disease.

  • PDF