• Title/Summary/Keyword: Optimized angle

Search Result 527, Processing Time 0.031 seconds

The Experimental Investigations of the Big Size Holographic Screen in the Autostereoscopic Displays

  • Son, J. Y.;Choi, Y. J.;Bahn, J. E.;Bobrinev, V.-I.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.55-59
    • /
    • 2001
  • Results of an experimental study of possible ways to extend the capabilities of a big size transmission type holographic screen are presented. Different approaches to the problem of making a big size screen have been considered and tested experimentally. Up to 60$\times$80 $\textrm{cm}^2$ screens have been recorded on a single photographic plate VRP-M. By attaching a mirror behind the screen, the reflection mode of operation has been obtained. In this arrangement some additional peculiarities appear in the screen, which can be used to extend the screen capabilities. The first possibility is to increase the screen size by mosaicking the subscreens in the reflection mode of operation. Screens of 120$\times$80 $\textrm{cm}^2$ and 180$\times$40 $\textrm{cm}^2$ have been obtained by proper alignment of 60$\times$40 $\textrm{cm}^2$ subscreens. The second possibility is to move the viewing Bone by rotation of the screen together with the mirror and thereby realize by the eye-tracking capability. Methods of increasing vertical size of the viewing zone have been considered. Along with the multi-exposure method, which was considered in previous papers, addition of the vertical diffuser with the optimized scattering angle has been tested experimentally. The vertical size of the viewing zone has been increased by up to 10-15 cm. Another method consists of usage of a diffraction grating with vertical dispersion to solve the same problem.

Evaluation of Wettability and Interfacial Property of Glass Fiber Reinforced Composite with Different Glass Fiber Conditions via Capillary Effect (Capillary 특성을 활용한 섬유 조건에 따른 유리섬유강화 복합재료의 함침성 및 계면강도 평가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.305-310
    • /
    • 2021
  • Mechanical properties of fiber reinforced composites were affected to fiber volume fractions (FVF) and interfacial property by sizing agent conditions. An optimum interface can relieve stress concentration by transferring the mechanical stress from the matrix resin to the reinforcements effectively, and thus can result in the performance of the composites. The interfacial properties and wettability between the epoxy resin and glass fiber (GF) were evaluated for different sizing agent conditions and FVFs. The surface energies of epoxy resin and different sizing agent treated GFs were calculated using dynamic and static contact angle measurements. The work of adhesion, Wa was calculated by using surface energies of epoxy matrix and GFs. The wettability was evaluated via the GF tow capillary test. The interfacial shear strength (IFSS) was evaluated by microdroplet pull-out test. Finally, the optimized GFRP manufacturing conditions could be obtained by using wettability and interfacial property.

Evaluation of Adhesion, Hydrophobicity and Color Gamut of Nanoparticle embedded Polyurethane Topcoat for Aircraft with 3 Different Nanoparticles (항공기용 3종류 나노입자들로 함침된 폴리우레탄 탑코트의 접착성, 소수성 및 색재현성 특성평가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.22 no.1
    • /
    • pp.16-21
    • /
    • 2021
  • In the aircraft industry, anti- and de-icing are one of very important techniques for the safety. The anti-icing technique had not been studied while de-icing technique had been not only researched enough but applied to aircraft industry. In this work, surface roughness and energies of polyurethane (PU) topcoat were controlled with 3 different nanoparticles which was coated to PU topcoat. It was evaluated via static contact angle using distilled water. The adhesion property of 3 nanoparticles was evaluated directly using adhesion pull-off test. The color gamut of nanoparticle coated PU topcoat was also evaluated with 3 different nanoparticles. It was determined using RGB color degree variation between neat PU topcoat and coated nanoparticle. Finally, the optimized nanoparticle was determined to manufacture hydrophobic surface and to maintain color of neat PU topcoat for the aircraft.

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

Numerical Study on Optimization of Bulb Type Twisted Rudder for KCS (KCS용 벌브형 비대칭 타의 최적화에 대한 수치적 성능 연구)

  • Kim, Myoung-Gil;Kim, Moon-Chan;Shin, Yong-Jin;Kang, Jin-Gu
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.419-426
    • /
    • 2018
  • Recently, in an effort to reduce the energy efficiency design index (EEDI), studies on energy saving devices (ESDs) have been conducted. In this study, we designed a post-device suitable for a KRISO container ship (KCS) using computational fluid dynamics (CFD). In order to increase the efficiency of the post-device, a twisted rudder was used, which has a proven performance (showing a 1.34% reduction in DHP compared to the bare hull at 24 knots) in previous research at Pusan National University. In addition, an increase in efficiency was expected by the use of a rudder bulb, including the discontinuous section of the twisted rudder and a divergent propeller cap to prevent the contraction of the wake. The optimization criterion was the case where the delivery power was the least compared with the bare hull. We analyzed the cause of the efficiency increase through an analysis of the self-propulsion factor. The case study for optimization was divided into 4 types (1. clearance of the bulb and cap, 2. shape of the bulb, 3. size of the bulb and cap, and 4. asymmetric bulb). Finally, with a clearance of 50 mm from the ship, a spherical bulb with the cap having an angle of $5^{\circ}$, and an asymmetric rudder bulb with a bulb diameter of 1.2HH/1.4H (horizontal/vertical) showed a 2.05% reduction in DHP compared to the bare hull at 24 knots. We will fabricate a post-device that will be optimized in the future and verify the performance of the post-device through model tests.

A Numerical Study for Optimum Design of Dust Separator Screen Based on Coanda Effect (코안다효과를 이용한 제진기 스크린의 최적설계를 위한 수치적 연구)

  • Yun, Seong-Min;Kim, Yong-Sun;Shin, Hee-Jea;Ko, Sang-Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.177-185
    • /
    • 2018
  • There is a need to study dust separator screens with good drainage efficiency while effectively filtering suspended solids and other contaminants entering the intake pumping station, the drainage pumping station and the mediation pumping station, the cooling water inlet of the power plant, and the like. In this paper, Numerical studies were conducted for the optimal design of the dust separator screen using the Coanda effect. The shape of the dust separator screen is important, such as the right curvature radius $R_1$ at the top of the dust separator screen and the left curvature radius $R_2$ at the top, h is the height difference and shape between the screen and the accelerating plate, and ${\theta}$ is the inclination angle of the screen. A total of 4 shape factors were set and the effects of Coanda and drainage performance of each element were compared and analyzed, the optimum length and size of each shape element were derived by classifying the shape elements into direct and indirect influences. Finally, it was possible to effectively filter foreign matter by narrowing the screen spacing, and the drainage performance was analyzed and optimized through numerical studies of dust separator screen.

Optimal Design of Impeller according to Blade Shape Variation Using CFD Simulation (CFD를 이용한 블레이드 형상 변화에 따른 블로워 임펠러 최적설계)

  • Yu, Da-Mi;Kim, Semo;Jang, Hye-Lim;Han, Dae-Hyun;Kang, Lae-Hyong
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.29-37
    • /
    • 2019
  • The objective of this study was to investigate the influence of the blade shape on the impeller performance, for design optimizing of the high airflow impeller. First, the quantity, angle, and length of blades, which are considered to have a large influence on the impeller performance, were selected as design variables. Then, 27 cases of impeller shapes were selected according to the design of experiment (DOE). To predict the conduct of the blower based on the selected impeller shape, flow analysis was performed using the immersed solid method of ANSYS CFX. In the CFD results, the highest airflow was expected in the impeller having a combination of 50 EA, $6^{\circ}$ and 5 mm. Finally, a blower with the original impeller shape and the optimized impeller shape was fabricated using a 3D printer, and the analysis tendency and experimental tendency were verified through experiments.

A Study on the Qualty Evaluation of the Turbo Factor of the SPACE(Sampling Perfection with Application optimized Contrast using different flip-angle Evolutions) 3D T2 Technique during Olfactory Bulb MRI Examination (Olfactory bulb MRI 검사 시 SPACE 3D T2 기법의 Turbo factor 변화에 따른 화질 평가에 관한 연구)

  • Lee, Jun-Kyu;Roh, Tae-Kwan;Jo, Yong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.115-122
    • /
    • 2022
  • This study aims to find out the change in diagnostic capability and image quality compared to 2D TSE T2 after examination the Turbo Factor value of the SPACE 3D T2 technique during Olfactory Bulb examination. As a result of the study, qualitative and quantitative analysis, it was found that there was a statistically significant difference in the SPACE 3D T2 technique compared to the 2D TSE T2 technique, and the conclusion

Optimized KNN/SVM Algorithm for Efficent Indoor Location (효율적인 실내 측위를 위한 KNN/SVM 알고리즘)

  • Kang, Il-Woo;Sharma, Ronesh;Jeon, Seong-Min;Park, Sun;Lee, Seong-Ho;Na, Young-Hwa;Bae, Jinsoo;Jung, Min-A;Lee, Yeonwoo;Lee, Seong-Ro
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.602-605
    • /
    • 2011
  • 현재 측위에 대한 측정 대상이 점점 작아지면서, 그에 따른 정확도 까지 높아지고 있다. 실내 측위에 관한 기술은 대표적으로 단말기의 수신신호의 세기방식인 RSS(Received Signal Strength), 수신신호의 도달시간 방식 TOA(Time of Arrival), 수신 신호의 도달 시간차 방식 TDOA(Time Difference of Arrival), 수신신호의 입사각 방식인 AOA(Angle of Arrival) 등 여러 가지 기술이 활발히 진행되고 있다. 본 논문은 특수 장비를 사용하지 않고, 무선 네트워크 기반의 실내 측위 중에 정확도가 높은 Fingerprinting 방법을 택하였다. WLAN 기반 실내측위에 가장 많이 사용되는 KNN은 k개의 이웃수와 RP의 수에 따라 민감하다. 본 논문에서는 KNN 성능을 향상 시키기 위해 SVM 이용하여 SNR 데이터를 군집화를 적용한 KNN과 SVM을 혼합한 알고리즘을 제안하였다. 제안한 알고리즘은 신호잡음비 데이터를 KNN 방법에 적용하여 k개의 RP를 선택한 후 선택된 RP의 신호잡음비를 SVM에 적용하여 k개의 RP를 군집하여 분류한다. 실험 결과 위치 오차가 2m이내에 KNN/SVM 혼합 알고리즘이 KNN 알고리즘보다 성능이 우수하다.

Effect of post-treatment routes on the performance of PVDF-TEOS hollow fiber membranes

  • Shadia R. Tewfik;Mohamed H. Sorour;Hayam F. Shaalan;Heba A. Hani;Abdelghani G. Abulnour;Marwa M. El Sayed;Yomna O. Mostafa;Mahmoud A. Eltoukhy
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.85-93
    • /
    • 2023
  • Membrane separation is widely used for several applications such as water treatment, membrane reactors and climate change. Cross-linked organic-inorganic hybrid polyvinylidene fluoride (PVDF) / Tetraethyl orthosilicate (TEOS) was adopted for the preparation of optimized hollow membrane (HFM) for membrane distillation or other low pressure separators for mechanical properties and permeability under varying pretreatment schemes. HFMs were prepared on semi-pilot membrane fabrication system. Novel adopted post-treatment schemes involved soaking in glycerol, magnesium sulphate (MgSO4), sodium hypochlorite (NaOCl), and isopropanol for different durations. All fibers were characterized for morphology using a scanning electron microscope (SEM), surface roughness using atomic force microscope (AFM), elemental composition by examining Energy Dispersive Spectroscopy (EDS), water contact angle (CA°) and porosity. The performance of the fibers was evaluated for pure water permeation flux (PWF). Post-treatment with MgSO4 gave the highest both tensile modulus and flux. Assessment of properties and performance revealed comparable results with other organic-inorganic separators, HF or flat. In spite of few reported data on post treatment using MgSO4 in presence of TEOS, this proves the potential of low cost treatment without negative impact on other membrane properties. The flux is also comparable with hypochlorite which manifests substantial precaution requirements in actual industrial use.The relatively high values of flux/bar for sample treated with TEOS, post treated with MgSO4 and hypochlorite are 88 and 82 LMH/bar respectively.