Abstract
This study aims to find out the change in diagnostic capability and image quality compared to 2D TSE T2 after examination the Turbo Factor value of the SPACE 3D T2 technique during Olfactory Bulb examination. As a result of the study, qualitative and quantitative analysis, it was found that there was a statistically significant difference in the SPACE 3D T2 technique compared to the 2D TSE T2 technique, and the conclusion
Keywords
3D SPACE T2; Turbo Factor; Olfactory Bulb;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Li T, Mirowitz S.A. "Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts", Magnetic Resonance Imaging, Vol. 38, pp. 21-29, 2009.   DOI
2 The Korean Society of MR Technology, Magnetic Resonance Imaging, DAEHAKSEORIM, pp. 121-122, 2019.
3 M. P. Lichy, B. M. Wietek, J. P. 3rd Mugler, W. Horger, M. I. Menzel, A. Anastasiadis, K. Siegmann, T. Niemeyer, A. Konigsrainer, B. Kiefer, F. Schick, C. D. Claussen, H. P. Schlemmer, "Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences", Investigative Radiology, Vol. 40, No. 12, pp. 754-760, 2005. https://doi.org/10.1097/01.rli.0000185880.92346.9e   DOI
4 M. Notohamiprodjo, B. Kuschel, A. Horng, D. Paul, P. Baer, G. Li, J. M. R. G. d. Olmo, M. F. Reiser, C. Glaser, "3D-MRI of the ankle with optimized 3D-SPACE", Investigative Radiology, Vol. 47, No. 4, pp. 231-239, 2012. http://dx.doi.org/10.1097/RLI.0b013e31823d7946   DOI
5 M. T. Shipley, "Transport of molecules from nose to brain: Transneuronal anterograde and retrograde labeling in the rat olfactory system by wheat germ agglutinin-horseradish peroxidase applied to the nasal epithelium", Brain Research Bulletin, Vol. 15, No. 2, pp. 129-142, 1985. http://dx.doi.org/10.1016/0361-9230(85)90129-7   DOI
6 C. D. Ward, W. A. Hess, D. B. Calne, "Olfactory impairment in Parkinson's disease", Neurology, Vol. 33, No. 7, pp. 943-946, 1983. http://dx.doi.org/10.1212/WNL.33.7.943   DOI
7 J. Hossein, F. Fariborz, R. Mehrnaz, Rafiei Babak, "Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging", European Journal of Radiology Open, Vol. 28, No. 6, pp. 36-41, 2018. https://doi.org/10.1016/j.ejro.2018.12.003   DOI
8 E. Iannilli, L. Stephan, T. Hummel, H. Reichmann, A. Haehner, "Olfactory impairment in Parkinson's disease is a consequence of central nervous system decline", Journal of Neurology, Vol. 264, No. 6, pp. 1236-1246, 2017. http://dx.doi.org/10.1007/s00415-017-8521-0   DOI
9 R. J. Zatorre, M. Jones-Gotman, A. C. Evans, E. Meyer, "Functional localization and lateralization of human olfactory cortex", Nature, Vol. 360, No. 6402, pp. 339-340, 1992. http://dx.doi.org/10.1038/360339A0   DOI